Page 3 - – A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
200-2341 3 Do not attempt to install the generator yourself. Extremely high and dangerous electrical voltages are present in utility power source lines and in generator load leads when the unit is running. Therefore, be sure to turn OFF all power voltage supplies at their source before attempting to...
Page 4 - Units with broken or missing parts, without; II
4 200-2341 The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground. Keep a fire extinguisher near the generator at all times. Extinguishers rated "ABC" by the National Fire Protection Associ...
Page 6 - The generator MUST be installed outdoors.
6 200-2341 Proper location of the generator set is important to insure safe and reliable operation and can aid in theinstallation of the generator. When selecting a site for thegenerator, first ensure that the pad is outdoors in a wellventilated area to allow for proper cooling and properremoval of ...
Page 7 - WA
200-2341 7 When connecting the generator to a building electrical distribution system, use of a transfer switch isrecommended to isolate the normal utility source fromthe generator supply. By preventing backfeed of thegenerator power into the utility lines during a utility poweroutage, the switch pr...
Page 10 - Select proper power output wire; MAIN; AUTOMATIC
10 200-2341 Once the generator is anchored in its final position, it is ready for electrical connections. The generator issupplied with two terminal blocks for connection of threedistinct electrical circuits; main line output power, GFCIpower input and remote start signal. Main line outputpower is t...
Page 11 - NEUTRAL
200-2341 11 A ground fault circuit interrupting (GFCI) receptacle is provided with the generator to power the batterycharger for reliable starting. It is also intended to poweran optional block heater if that option is desired.Connection of this circuit to a power supply that is only present when no...
Page 13 - FUEL CONSUMPTION TABLE
200-2341 13 The engine driving the generator is engineered to provide reliable power on either Liquefied Propane Vapor(LPG) or Natural Gas. For proper operation on thesefuels, it is important to deliver gas with adequate energycontent, at sufficient pressure and flow rate. This isdesigned to operate...
Page 16 - To insure reliable starting in most weather; BCI; recommended rating of; Use tools with insulated handles.
16 200-2341 To insure reliable starting in most weather conditions, it is important to properly match a battery tothe requirements of the generator. The generator uses a12 Volt, direct current, negative ground control systempowered by an automotive style lead acid battery.Successful engine starting ...
Page 23 - Keep clear of all moving parts at all times.
200-2341 23 Two methods are available to start the generator. The automatic, or AUTO mode is for use with anautomatic transfer switch. With the control panel modeswitch set to this position, the generator waits for anexternal signal to start. This signal is supplied by thetransfer switch when utilit...
Page 26 - UPPER LIMIT; Eye protection should be used.
26 200-2341 Prior to checking the oil level, start the generator by moving the Mode switch on the control panel to the RUNposition. Allow the generator to run for one or twominutes, then shut it down by returning the switch to theOFF position. After the engine comes to a stop let theengine set for a...
Page 27 - Chart C
200-2341 27 Selection of the correct grade and type of engine oil greatly affects the performance of the generator,especially when starting. Before selecting replacementoil for an oil change, consider the anticipated operatingconditions the generator may be exposed to. Choose theappropriate weight o...
Page 29 - Table A
200-2341 29 5. Insure the the battery charger is powered and functioning properly. A correctly operating battery charger displays lights on the face of the charger to relay the state of the charger. To locate the battery charger ( A ) and check the lights ( B ) (see note below) refer to Fig F. Refer...
Page 33 - Do not smoke when near the unit.
200-2341 33 Over time, normal engine operation leads to wear in the engine valve train which decreases generator output.To restore generator output, it is necessary to check andadjust the engine valve lash at regular intervalsthroughout the life of the engine. However, proper valvelash adjustments r...
Page 34 - SYMPTOM
34 200-2341 T T T T R R R R O O O O U U U U B B B B L L L L E E E E S S S S H H H H O O O O O O O O T T T T II II N N N N G G G G SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Engine does not crank Loose battery cables • Check all battery cable connections Defective battery • Test battery. Replace as nec...
Page 40 - Detail A
40 200-2341 P P A A R R T T S S D D R R A A W W I I N N G G - - H H 2 2 X X B B R R E E A A K K D D O O W W N N P P A A R R T T S S L L I I S S T T Item Part No Qty Description 1 094-0091 1 Insulation 2 115-0268 1 Panel, left side (includes item 1) 3 N/A 4 Screw, 10-32 x .50” lg 4 N/A 1 Bolt, 5/16 N...
Page 46 - How To Obtain Warranty Performance:
46 200-2341 Coleman PowerStation™ Stationary Standby 3-Year or 1500 Hour Limited Warranty Your Coleman PowerStation™ emergency back up power system generator has been manufactured to stringent guidelines &standards for years of dependable operation & service. Coleman Powermate warrants this ...
Page 47 - Una descripción breve del problema con el generador.; COMMENT COMMANDER DES PIÈCES DE RECHANGE; renseignements suivants :; CONTACT THE COLEMAN POWERMATE PRODUCT SERVICE DEPARTMENT AT
200-2341 47 COMUNÍQUESE CON EL DEPARTAMENTO DE SERVICIO DE PRODUCTOS COLEMAN POWERMATE EN EL TELÉFONO 1-800-445-1805 para obtener información sobre servicios de garantía o para pedir piezas de repuesto o accesorios. CÓMO PEDIR PIEZAS DE REPUESTO Incluso los equipos de calidad como el generador de em...