Page 2 - Contents; Before using the device
2 Contents Before using the device Introduction ................................................................................................... 3Intended use .................................................................................................. 3Important safety instructions............
Page 4 - Important safety instructions; respiratory therapist.
4 Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following:...
Page 5 - been used on average for more than 60 days, replace it with a new one.
5 Important safety instructions EN • Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device. • Do not operate the device with a damaged power cord or plug.• Keep the power cord away from heated surfaces.• Read and follow the “Important information regarding Electro M...
Page 6 - the power while nebulising.; General Safety Precautions:; Save these instructions for future reference.
6 Important safety instructions • Do not block the slit between the cap and the inhalation air inlet.• Do not use a microwave oven or hair dryer to dry the nebulising parts.• Approved for human use only.• If the device is used continuously, the service life of the device may be shortened.• Limit use...
Page 7 - Inhalation Attachments; Power Switch; Nebuliser Kit
7 EN 1. Know your unit Air Tube (PVC, 100cm) Air Tube Connector Nebuliser Kit Holder Air Filter Cover*Air filter inside Power Connector Compressor (Main Unit) Cap Inhalation Air Inlet Inhalation Top Vaporiser Head Medication Tank Air Tube Connector Nozzle Mouthpiece Child Mask (PVC) Adult Mask (PVC)...
Page 8 - Vaporiser Head; TM
8 1. Know your unit Accessories Material of attachment • Also applicable Section 10. Optional parts and accessories (page 29). Nebuliser Kit (Cap, Inhalation Top, Medication Tank), Mouthpiece, Nosepiece, Adapter for Child Mask: Polypropylene (Phthalate free) Vaporiser Head Polycarbonate (Phthalate f...
Page 9 - Guide to using the device; • Do not tilt the nebuliser kit so that it is at an; How the nebuliser kit works; Operating instructions
9 EN 2. Guide to using the device Preparing the Nebuliser for Use - Section 3 (page 10-13) Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than...
Page 10 - Make sure that the power switch is turned off.
10 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on c...
Page 11 - Preparing the nebuliser for use; Adding medication and assembling the parts; Rotate the inhalation top anti-clockwise.
11 3. Preparing the nebuliser for use EN 3.2 Adding medication and assembling the parts 1. Remove the mouthpiece and cap from the nebuliser kit. 2. Remove the inhalation top from the medication tank. 1) Rotate the inhalation top anti-clockwise. 2) Lift the inhalation top out of the medication tank. ...
Page 12 - Attaching the mouthpiece
12 3. Preparing the nebuliser for use 6. Attach the desired inhalation attachment, as described below. Attaching the mouthpiece 1) Attach the cap to the inhalation air inlet. 2) Attach the mouthpiece to the inhalation top. Attaching the nosepiece 1) Attach the cap to the inhalation air inlet. 2) Att...
Page 13 - the nebuliser kit upright.
13 3. Preparing the nebuliser for use EN 7. Attach the air tube. 1) Twist the air tube plug slightly and push it firmly into the air tube connector on the compressor. 2) Twist the air tube plug slightly and push it firmly into the air tube connector on the medication tank. Notes: • Make sure that th...
Page 14 - Do not cover the compressor with a blanket or towel etc., during use.
14 4. Taking medication 1. Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. 2. Press the power switch to the on ( ) position. The compressor starts and nebulisation starts. Note...
Page 16 - Care and maintenance
16 4. Taking medication 4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moistur...
Page 17 - Make sure that the power switch is in the off (
17 EN 5. Cleaning and daily disinfecting 5.1 Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections. Warning: Thoroughly rinse the nebuliser kit a...
Page 18 - Cleaning and daily disinfecting; The compressor is not waterproof.; Reassemble the nebuliser kit. Put it in the storage bag.; Disinfecting the nebulising parts; Remove the parts and discard the solution.
18 5. Cleaning and daily disinfecting 7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. 8. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. ...
Page 19 - Handling the Vaporiser Head; • Always wash the vaporiser head after each
19 5. Cleaning and daily disinfecting EN Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication.Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each use. Failure to do so could cause block...
Page 21 - * an example of commercially available disinfectant.
21 5. Cleaning and daily disinfecting EN O: applicable ×: not applicable * an example of commercially available disinfectant. Boiling Alcohol Sodium hypochlorite Quaternary ammonium Chlorhexidine Amphoteric surfactant Disinfecting ethanol Milton* (0.1%) Osvan* (0.1%) Hibitane* (0.5%) Tego* (0.2%) O ...
Page 22 - Maintenance and storage; under direct sunlight.; in
22 6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the device unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks su...
Page 23 - Changing the air filter; Change the air filter.
23 EN 7. Changing the air filter If the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one. 1. Pull the air filter cover off the compressor. 2. Change the air filter. 3. Put the air filter cover back in place. Notes: • Use only OMRON air filte...
Page 24 - Is the nozzle blocked?
24 8. Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Note: If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Return...
Page 26 - Result of cascade impactor measurements for particle size**; drug supplier’s data sheet for further details.; ml maximum
26 9. Technical data Technical data for the OMRON NE-C24 Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Result of cascade impactor measurements for particle size** * Measured by OMRON HEALTHCARE Co., Ltd.**Independently measured by Prof. Dr. Hiroshi Takano, Department of ...
Page 29 - Optional parts and accessories
29 EN 10.Optional parts and accessories Omron V.V.T. Nebuliser Kit N-01 Set Model: C801-NSET3Order No.: 9515573-6 Air Tube (PVC, 100cm) Model: C801-ATBPOrder No.: 9515575-2 Mouthpiece Model: C28-3POrder No.: 9956273-5 Air Tube (Silicon, 100cm) Model: C28-6Order No.: 9956269-7 Nosepiece Model: C28-7O...
Page 30 - Optional parts and accessories; Made in China
30 10. Optional parts and accessories Made in China Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto,617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR HoofddorpTHE NETHERLANDSwww.omron-healthcare.com Exclusive distributor in Russia &...
Page 36 - OMRON
36 • . • . • . • . • 20 . 40 . • . • , , , , . • , . ( я ) • . • . . • . • Ш . • . • , OMRON HEALTHCARE, . • . : • , . , : - , . - . - . • , . . Э . • . - . • +40 °C. • , , . , , . • , . , . • « » ( . 58) , . я я . NE-C24_RU.book Page 36 Thursday, October 25, 2012 1:50 PM
Page 44 - Д я
44 4. 1. , . : я 45°. . 2. , « » ( ). К . : , . Д я , , « » ( ). : я , . . : • . • 20 я . 40 . • я . • , , , , я я я . : . Э . 45 ° NE-C24_RU.book Page 44 Thursday, October 25, 2012 1:50 PM
Page 48 - я я
48 5. 7. , , . : я я я . 8. , , . 9. . . : . 5.2 я . ( . 5.1 « ») , . . . 50 -51. , : A. . . 1. . 2. . 3. , . B. 15-20 . , . : я , . Мягкое моющее средство NE-C24_RU.book Page 48 Thursday, October 25, 2012 1:50 PM
Page 56 - MMAD = Mass Median Aerodynamic Diameter (
56 9. OMRON NE-C24 OMRON V.V.T. (Virtual Valve Technology - я ): ** * OMRON HEALTHCARE Co., Ltd. ** . - , , , , К , , EN 13544-1:2007 я : • , , . . • . - OMRON HEALTHCARE EUROPE.URL: www.omron-healthcare.com : ** - . 3 μ MMAD = Mass Median Aerodynamic Diameter ( ) я : . 7 : 2 7 : * . 46 ( я ): * . 0...
Page 58 - щ я
58 9. щ я я ( ) Э , . , , . , , , , . . . . NE-C24_RU.book Page 58 Thursday, October 25, 2012 1:50 PM
Page 60 - К А
К OMRON HEALTHCARE CO., LTD.( ., .) 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN(53, К , - , , К , 617-0002 ) OMRON HEALTHCARE EUROPE B.V.( . .) Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS( 33, 2132 , А Ы ) www.omron-healthcare.com « » 123557, , , . ., . 26, . 13-14 www.csmedica.ru - O...