Page 2 - OMEGAnet
Servicing North America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTel: (514) 856-6928FAX: (514) 856-6886e-mail: [email protected] For immediate technical or app...
Page 3 - User Manual
USB-4761 8-channel Relay / Isolated DI USB Data Acquisition Module User Manual
Page 4 - Contents; Chapter 1 Introduction
Contents Chapter 1 Introduction ..................................................... 2 1.1 Features ............................................................................. 2 1.1.1 Robust Protection ........................................................... 3 1.1.2 Wide Input Range .............
Page 6 - Introduction
1 2 Introduction This chapter will provide information on the features of the DAS module, a quick start guide for installation, and some brief information on software and accessories for the USB-4761 Module. Sections include: • Features • Applications • Installation Guide • Software Overview • Devic...
Page 7 - Chapter 1 Introduction
Chapter 1 Introduction Thank you for buying the USB-4761 data acquisition module. The USB-4761 is a powerful data acquisition (DAS) module for the USB port. It features a unique circuit design and complete functions for data acquisition and control. 1.1 Features USB-4761 has the most requested measu...
Page 8 - Reset Protection for Industrial Applications
1.1.1 Robust Protection The USB-4761 digital input channels feature a robust isolation protection for industrial, lab and machinery automation applications. It durably withstands voltage up to 2,500 VDC, preventing your host system from any incidental harms. If connected to an external input source ...
Page 9 - Installation Guide
1.2 Applications • Industrial On/Off control • Switch status sensing • Digital I/O control • Industrial and lab automation • SMT/PCB machinery • Semi-conductor machinery • PC-based Industrial Machinery • Testing & Measurement • Laboratory & Education • External relay driving 1.3 Installation...
Page 11 - Software Overview
1.4 Software Overview OMEGA offers a rich set of DLL drivers, third-party driver support and application software to help fully exploit the functions of your USB-4761 module: • Device Drivers (on the companion CD-ROM) 1.4.1 Programming Choices for DA&C Module: You may use the application softwar...
Page 12 - Device Driver Programming
1.5 Device Driver Programming This section will provide a roadmap to demonstrate how to build an appli- cation from scratch using the Device Drivers with your favorite development tools such as Visual C++, Visual Basic. The step-by-step instructions on how to build your own applications using each d...
Page 14 - Installation
2 2 Installation This chapter has a package item check- list, proper instructions about unpack- ing and step-by-step procedures for both driver and USB installation.. Sections include: • Unpacking • Driver Installation • Hardware Installation • Device Setup & Configuration • Device Testing • Har...
Page 15 - Chapter 2 Installation; After taking out the module, you should first:
Chapter 2 Installation 2.1 Unpacking After receiving your USB-4761 package, please inspect its contents first. The package should contain the following items: • USB-4761 Module • Shielded USB 2.0 Cable (1.8 m) • Companion CD-ROM (DLL driver included) The USB-4761 Module harbors certain electronic co...
Page 16 - Driver Installation
2.2 Driver Installation We recommend you install the software driver before you install the USB-4761 module into your system, since this will guarantee a smooth installation process. The 32-bit DLL driver Setup program for the USB-4761 module is included on the companion CD-ROM that is shipped with ...
Page 17 - Device Driver’s Manual; Hardware Installation
Step3: Click Continue , and select the Installation option Step4: Select the specific device and then just follow the installation instructions step by step to complete your device driver installation and setup. For further information on driver-related issues, an online version of the Device Driver...
Page 23 - Hardware Uninstallation
. Figure 2.7: Digital Output Tab in Device Test Dialog Only after your module device is properly set up, configured and tested, can the device installation procedure be considered complete. After the device installation procedure is completed, you can safely proceed to the next chapter , Signal Conn...
Page 26 - Signal Connections
3 2 Signal Connections This chapter provides useful informa- tion on how to connect input and output signals to the USB-4761 via the I/O connectors.. Sections include: • Overview • I/O Connectors • Field Wiring Considerations
Page 27 - Chapter 3 Signal Connections
Chapter 3 Signal Connections 3.1 Overview Maintaining good signal connections is one of the most important factors in ensuring that your application system is sending and receiving data correctly. A good signal connection can avoid unnecessary and costly damage to your PC and other hardware devices....
Page 30 - Isolated Digital Input Connections; Relay Connections
3.3 Isolated Digital Input Connections 3.3.1 Single-ended Channel Connections USB-4761 has 8 isolated digital input channels. Each of isolated digital input channel accepts 10~30 V DC voltage inputs, and accept bi-direc- tional input. It means that you can apply positive or negative voltage to an is...
Page 31 - Field Wiring Considerations
3.5 Field Wiring Considerations • When you use USB-4761 to acquire data from outside, noises in the environment might significantly affect the accuracy of your measure- ments if due cautions are not taken. The following measures will be helpful to reduce possible interference running signal wires be...
Page 32 - Specifications
Page 33 - Appendix A Specifications; A.1 Isolated Digital Input
Appendix A Specifications A.1 Isolated Digital Input Channels 8 Optical Isolation 2,500 VDC Opto-isolator response time 25us Input Voltage VIH (max.) 30VDC VIH (min.) 5VDC VIL (max,) 2VDC Input current 5VDC 1.2mA 12VDC 3.3mA 24VDC 6.9mA 30VDC 8.7mA A.2 Relay Output Channels 8 Relay Type Form C Ratin...
Page 36 - Function Block
Page 37 - Appendix B Function Block
Page 38 - RETURN REQUESTS/INQUIRIES
WARRANTY/ DISCLAIMER O M E G A E N G I N E E R I N G , I N C . w a r r a n t s t h i s u n i t t o b e f r e e o f d e f e c t s i n m a t e r i a l s a n dworkmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1...
Page 39 - TEMPERATURE
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ ...