Page 2 - Servicing North America:
OMEGAnet ® On-Line Service Internet e-mail omega.com [email protected] It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuingcertification of its products to the European New Approach Directives. OMEGA will add th...
Page 3 - Ultra-Low Flow Sensors; Section
TABLE OF CONTENTS FTB600B Series Ultra-Low Flow Sensors i Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1B. Principle of Operation .................................
Page 5 - A. General Description
1 1 FTB600B Series Installation IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFOREINSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meterbased on the pelton wheel principle. This unique patented designmakes the FTB600B Ser...
Page 6 - Imbrittled by some amines, keystone and esters.
2 FTB600B SeriesInstallation 1 C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - KynarAll wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or couldcome in contact with the flui...
Page 7 - Operating Parameters; Over range may permanently damage the flow meter.; WA R N I N G
3 2 FTB600B Series Operating Parameters Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into thebody of the meter it is strongly recommended that 180°F not beexceeded. Exceeding 180°F can cause irreparable damage to the circuitboards. B. Fl...
Page 9 - C. Recommended Viscosity
5 FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbinemeter is a viscosity dependent device, where as the viscosit...
Page 10 - Section 3 - Silicone Treatment
6 3 FTB600B SeriesSilicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series serieselectronics.
Page 11 - Output impedance 75 ohms
7 4 FTB600B Series Infrared Sensors Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating andeventual failure of all PC boards. Printed circuit boards are non-repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Outpu...
Page 12 - N O T E
8 FTB600B SeriesInfrared Sensors 4 C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22...
Page 13 - Infrared Sensors
9 FTB600B Series Infrared Sensors 4 Figure 4-1. Output Frequency Waveforms
Page 14 - Section 5 - Installing the FTB600B Series in the fluid line.; The FTB600B Series is now ready for use.
10 5 FTB600B SeriesInstallation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride)and meets viscosity, pressure and temperature parameters of theFTB600B Series. The fluid must also meet filtration requirements asliste...
Page 17 - Installation
13 FTB600B Series Installation 5 Table 5-1. Piping Table Con't.
Page 18 - Section 6 - Specifications; PVDF; Output Signal; Unscaled square wave
14 6 FTB600B SeriesSpecifications Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressure: 150 PSIG at 175°F Wetted Materials: PVDF Power Supply: 5 to 18 Vdc, 6 to 33 mA Output Signal : Unscal...
Page 19 - Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601; kP
15 7 FTB600B Series Pressure Drop Curves Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 0.5 0 1.0 Liters/minute kP a 1.5 2.0 45 40 35 30 25 20 15 10 5 0
Page 20 - Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602
16 FTB600B SeriesPressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 2.0 0 4.0 Liters/minute kP a 8 .0 6.0 10.0 200 150 100 50 0
Page 22 - Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604
18 FTB600B SeriesPressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 10 20 30 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0
Page 24 - Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A
20 FTB600B SeriesPressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 1 8 0 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 70 8 090 0 Liters/minute kP a 0
Page 25 - WARRANTY / DISCLAIMER
FOR WARRANTY RETURNS, please have the following information available BEFORE contactingOMEGA:1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-...
Page 26 - Where Do I Find Everything I Need for
TEMPERATURE 䡺 ⻬ Thermocouple, RTD & ThermistorProbes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & Process Monitors 䡺 ⻬ Infrared Pyrometers PRESSURE, STRAIN AND FORCE 䡺 ⻬ Transducers &...