Omega DPG3500 - Manual

Omega DPG3500

Omega DPG3500 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – NEVER; NS; X X X X X
  • Page 3 – Calibration Precautions; Calibration Preparation; DOWN
  • Page 4 – OMEGAnet; One Omega Drive, River Bend Technology Centre; RETURN REQUESTS / INQUIRIES; WARRANTY; OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
Loading the manual

Digital Pressure Gauges

DPG3500, DPG5500, and DPG5600

INSTRUCTION

SHEET

M4094-0606

Shop online at: omega.com e-mail: [email protected]
For latest product manuals: omegamanual.info

Accuracy

(linearity, hysteresis, repeatability)

±0.25% of full scale ±1 least significant digit

Display

(update rate, type, size)

3 readings per second nominal update rate
4 digit LCD, 0.4" digit height
5 character 0.25" H alphanumeric display

DPG5600

: Red LED backlight. Backlighting may

not be visible under bright lighting conditions.

Calibration

Internal calibration pushbuttons, non-interactive
zero, midpoint, span, ±10% range

Shutoff

See gauge rear label, last character of model
number

-5

:

5 minute auto shutoff (standard)

-NS

:

No auto shutoff, on/off via front pushbutton

Function

Pushbutton

Prompt (Release Button)

Result

On

Press 1 sec

Gauge Range/Display Test

Actual Pressure

Zero

Press/hold

oooo

Zeroed Actual Pressure

Hi Reading

Press/hold

HI

HI

& max. reading

Lo Reading

Press/hold

Lo

Lo

& min. reading

Exit Hi/Lo

Press/hold

AP

Actual Pressure

Clear Hi/Lo

Press/hold

HI

/

LO

/

AP

Ci

r

Actual Pressure

Clear Zero, Off

Press/hold

HI

/

LO

/

AP

Ci

r

OFF

Clear Zero, Gauge Off

Batteries & Battery Life

DPG3500 and DPG5500

2 AA alkaline, approx. 2000 hours

DPG5600

2 AA alkaline, approx. 150 to 1500 hrs depending
on backlight usage

Low Battery Indication

Low battery symbol on display when batteries
must be replaced

Dimensions

(see drawing on next page)

DPG3500

3.5" W x 3.0" H x 2.0" D NEMA 4X housing
Add approx. 0.75" to height for pressure fitting

DPG5500

and

DPG5600

3.38" W x 2.88" H x 1.65" D housing
Add approx. 0.75" to height for pressure fitting

Weight

(approximate)

Gauge:

9 ounces

Shipping weight: 1 pound

Material & Color

DPG3500

Light gray ABS/polycarbonate NEMA 4X case,
rear gasket, polycarbonate label

DPG5500

and

DPG5600

Extruded aluminum case, light gray epoxy
powder coated, black ABS/polycarbonate bezel,
front and rear gaskets, polycarbonate label

Connection Size

1

/

4

" NPT male

Sensor Material

All wetted parts are 316 stainless steel

Overpressure

2 times sensor range
3000 psig range & metric equivalents: 5000 psig
5000 psig range & metric equivalents: 7500 psig
112.5% out-of-range display:

i

– – – or

i

–.–.–.–

depending on model

Burst Pressure

4 times sensor pressure rating, or 10,000 psi,
whichever is less

Storage Temperature

–40 to 203°F (–40 to 95°C)

Operating Temperature

–4 to 185°F (–20 to 85°C)

Compensated Temperature

32 to 158°F (0 to 70°C)

Temperature Stability

±0.5% span typical, ±1% span max. 0 to 82°C

MADE IN

Ranges and Resolution

Resolution is fixed as indicated in table
Ranges in

Bold

are standard. Contact Omega Engineering for other ranges listed below.

abs:

Absolute reference (normally reads atmospheric pressure, reads zero at full vacuum)

vac:

Vacuum gauge, minus sign not used unless specified

–30.00 inHg/15.00 psig

120.0 inHg

1600 mmHg

35.00 bar

1.000 kg/cm

2

abs

–30.0 inHg/100.0 psig

200.0 inHg abs

760.0 torr abs

70.00 bar

1.000 kg/cm

2

vac

–30.0 inHg/200.0 psig

200.0 inHg

1600 torr abs

140.0 bar

±1.000 kg/cm

2

3.000 psig

50.00 oz/in2

2100 mmH

2

O

200.0 bar

1.000 kg/cm

2

5.000 psig

80.0 oz/in2

3500 mmH

2

O

350.0 bar

2.000 kg/cm

2

abs

15.00 psi abs

240.0 oz/in2 abs

200.0 cmH

2

O

20.00 kPa

2.000 kg/cm

2

15.00 psig vac

240.0 oz/in2 vac

350.0 cmH

2

O

35.00 kPa

4.000 kg/cm

2

±15.00 psig

±240.0 oz/in2

1000 cmH

2

O

100.0 kPa abs

7.000 kg/cm

2

abs

15.00 psig

240.0 oz/in2

2100 cmH

2

O

100.0 kPa vac

7.000 kg/cm

2

30.00 psi abs

85.0 inH

2

O

200.0 mbar

±100.0 kPa

14.00 kg/cm

2

30.00 psig

140.0 inH

2

O

350.0 mbar

100.0 kPa

20.00 kg/cm

2

60.00 psig

400.0 inH

2

O abs

1000 mbar abs

200.0 kPa abs

35.00 kg/cm

2

100.0 psi abs

400.0 inH

2

O vac

1000 mbar vac

200.0 kPa

70.00 kg/cm

2

100.0 psig

±400 inH

2

O

±1000 mbar

400.0 kPa

140.0 kg/cm

2

200.0 psig

400.0 inH

2

O

1000 mbar

700.0 kPa abs

200.0 kg/cm

2

300.0 psig

850 inH

2

O

2000 mbar abs

700.0 kPa

350.0 kg/cm

2

500.0 psig

7.000 ftH

2

O

2000 mbar

1500 kPa

1.000 atm abs

1000 psig

12.00 ftH

2

O

4000 mbar

2000 kPa

±1.000 atm

2000 psig

35.00 ftH

2

O

1.000 bar abs

3500 kPa

1.000 atm

3000 psig

70.00 ftH

2

O

1.000 bar vac

5000 kPa

4.000 atm

5000 psig

140.0 ftH

2

O

±1.000 bar

3.500 MPa

7.000 atm

6.000 inHg

230.0 ftH

2

O

1.000 bar

7.000 MPa

14.00 atm

10.00 inHg

480.0 ftH

2

O

2.000 bar abs

14.00 MPa

20.00 atm

30.00 inHg abs

150.0 mmHg

2.000 bar

20.00 MPa

35.00 atm

30.00 inHg vac

260.0 mmHg

4.000 bar

35.00 MPa

70.00 atm

±30.00 inHg

760.0 mmHg abs

7.000 bar abs

1000 g/cm

2

abs

135.0 atm

30.00 inHg

760.0 mmHg vac

7.000 bar

1000 g/cm

2

200.0 atm

60.00 inHg abs

760.0 mmHg

14.00 bar

2100 g/cm

2

abs

340.0 atm

60.00 inHg

1600 mmHg abs

20.00 bar

2100 g/cm

2

Controls & Functions

All Models:

Front pushbutton turns gauge on or off and cycles through functions

DPG5600

:

Press pushbutton to activate 1 minute backlighting when gauge is on

DPG5500,
DPG5600

DPG3500

DPG3500

Battery Powered, Min/Max/Zero, NEMA 4X Housing

DPG5500

Battery Powered, Min/Max/Zero

DPG5600

Battery Powered, Min/Max/Zero, Display Backlighting

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NEVER; NS; X X X X X

DPG3500, DPG5500, and DPG5600 Series 2 Installation and Precautions Install or remove gauge usingwrench on hex fitting only. Don o t a t t e m p t t o t i g h t e n b ytur ning housing or any otherpart of the gauge. See gauge rear label for pressure range! Use fittings appropriate for the pressure r...

Page 3 - Calibration Precautions; Calibration Preparation; DOWN

Calibration Precautions Install or remove gauge using wrench on hex fitting only.Do not attempt to tighten or loosen by turning housing orany other part of the gauge. See gauge rear label for pressure range! Use fittings appropriate for the pressure range of the gauge. The gaugerange is indicated on...

Page 4 - OMEGAnet; One Omega Drive, River Bend Technology Centre; RETURN REQUESTS / INQUIRIES; WARRANTY; OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to theEuropean New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in...