Servicing North America: USA: USA: USA: USA: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: Canada: Canada: Canada: Canada: 976 BergarLaval (Quebec) H7L 5A1Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail:...
Page i 1.0 TABLE OF CONTENTS: 1.0 Table of Contents: ........................................................... i Warning and Safety Notice .................................................... v 2.0 Overview ......................................................................... 1 2.1 General Des...
Warnings and Safety Precautions Page iv 09/11/2008 REV 0.99 NOTE The contents of this manual are correct at the time of issue. The contents may change at any time without prior notification. This is due to continuous developments to the recorder and its functionality. Trademarks Microsoft, MS-DOS,...
Warnings and Safety Precautions Page v 09/11/2008 REV 0.99 WARNING AND SAFETY NOTICE This Safety Notice has been included to emphasize the DANGER OF HAZARDOUS VOLTAGES on the REAR TERMINAL PANEL of your instrument. USE EXTREME CAUTION WHEN INSTALLING OR SERVICING your instrument. Please read the ent...
Section 2 - Overview Page 1 09/11/2008 REV 0.99 2.0 OVERVIEW This manual applies to Firmware version 1.0 and above. This section gives a system overview of the recorder and the basic elements involved. 2.1 General Description The recorder is an 18 channel unit capable of measuring 6 or 12 live input...
Section 2 - Overview Page 2 09/11/2008 REV 0.99 Figure 2-1 System Overview DIGITAL INPUTS ANALOG INPUTS RELAY OUTPUTS MASTER ENABLE MASTER ENABLE DATA MANAGER DIGITAL INPUT MANAGER ALARM EVENT MANAGER DISPLAY & KEYBOARD MANAGER DATA STORAGE MANAGER SYSTEM MANAGER USB A/B RS232/485 AUDIO IO Syste...
Section 2 - Overview Page 4 09/11/2008 REV 0.99 2.3 Recorder Front Figure 2-2 shows the front view of the recorder. The recorder has a ¼ VGA color display with touch screen. Below the display are a lockable media door, status indicator, IR COMM port and stylus used for data entry on the display. The...
Section 2 - Overview Page 5 09/11/2008 REV 0.99 Figure 2-3 Media Door Contents RESET BUTTON COMPACT FLASH CARD SOCKET CARD EJECT BUTTON USB A SOCKET 2.3.2 Media Door The media door is opened by turning the key in the lock ¼ turn clockwise and pulling the door out and down. Note that in order to meet...
Section 2 - Overview Page 6 09/11/2008 REV 0.99 AC POWER INPUT 24 VDC OUTPUT OPTION SYSTEM GROUND LUG BATTERY DISCONNECT ANALOG INPUTS CHANNELS 7 – 12 (OPTIONAL) ANALOG INPUTS CHANNELS 1 – 6 INPUT/OUTPUT MODULE (OPTIONAL) USB TYPE A (MASTER) USB TYPE B (SLAVE) MEMORY EXPANSION SLOT MOUSE/KEYBOARD CO...
Section 2 - Overview Page 7 09/11/2008 REV 0.99 have an isolated frequency inputs which allows the unit to measure frequency to 10,000 Hz. Between the terminal blocks is the ambient temperature sensor for thermocouple compensation. 2.4.3 Input/Output Module The input/output module is optional and pr...
Section 2 - Overview Page 8 09/11/2008 REV 0.99 2.5 Files 2.5.1 Configuration Files The recorder has hundreds of options and settings that need to be set up by the user. Things like input types, point tags, displays, record information and so-on. Once set up, this information is saved in the interna...
Section 2 - Overview Page 9 09/11/2008 REV 0.99 Eg: To copy the “pumphouse” configuration to a different media you need to go to the ConfigFiles directory and copy the FOLDER “pumphouse_cfg”. In the root of the internal memory (SD card) are two files – config.xml and displays.xml. These are the defa...
Section 2 - Overview Page 10 09/11/2008 REV 0.99 2.7 QUICK START GUIDE The recorder ships in a fully functional mode, but may not be set up the way you would want to use it and needs to be configured before it is used. There are several areas that need to be configured to customize the unit to the u...
Section 2 - Overview Page 11 09/11/2008 REV 0.99 Figure 2-5 On-screen Keyboard Figure 2-6 On-screen Help Figure 2-7 Activity Lights 2.8 Keyboarding While it is possible to connect a standard keyboard and mouse to the recorder, one may not be readily available in which case data is entered using the ...
Section 2 - Overview Page 12 09/11/2008 REV 0.99 2.11.1 User Levels There are three user levels for gaining direct access to the recorder. User levels are only active if security is enabled. The three levels are Administrator: Has access to all levels of the recorder menus and systems. Manager: Has ...
Section 3 – Installation Page 13 09/11/2008 REV 0.99 3.0 INSTALLATION This section provides information and procedures on installing and wiring the recorder. Included are handling procedures, installation and wiring specifications, and instructions for both standard and optional equipment. 3.1 Equip...
Section 3 – Installation Page 14 09/11/2008 REV 0.99 NOTE: The recorder is designed to be panel mounted and as such should be considered as permanently connected. Disconnection from the supply must be possible via a customer supplied switch or circuit breaker. This disconnection device must be inclu...
Section 3 – Installation Page 15 09/11/2008 REV 0.99 3.3.1 Panel Mounting The recorder should be mounted in a vertical panel to ensure proper operation. Note that the locking bars can be used on the sides or top and bottom of the unit depending on available space. Ensure you have the proper clearanc...
Section 3 – Installation Page 17 09/11/2008 REV 0.99 3.4 Wiring Specifications and Procedures 3.4.1 Power Requirements The recorder operates on any voltage from 100 to 240 Vac +10%, 50/60 Hz enabling it to be used in most countries. The maximum apparent power required by the unit is 35 VA. 3.4.2 Pow...
Section 3 – Installation Page 18 09/11/2008 REV 0.99 3.4.3 Signal Input Wiring Signal input connections. Hazardous potentials may exist on signal input terminals which are floating with respect to case ground. These hazardous pot entials may be on the rear terminal panel of your instrument. Any volt...
Section 3 – Installation Page 19 09/11/2008 REV 0.99 Read the following procedures prior to connecting inputs to the terminals. WARNING: Ensure the power is off before connecting signal inputs to the unit. The plug in screw terminal connectors are of the clamping screw variety, putting even pressure...
Section 3 – Installation Page 20 09/11/2008 REV 0.99 3.4.3.5 Potential Free Contacts Normally open/closed contact inputs. 3.4.3.6 Frequency Available on channels 1, 6, 7 and 12 only. Default input is for 12 to 24V DC @ 20mA max. The inputs can be jumpered internally for 5 to 12V dc. See Appendix B f...
Section 3 – Installation Page 21 09/11/2008 REV 0.99 3.4.4 Relay Output, Contact Input WARNING To prevent the possibility of electrical shock, use extreme caution when wiring contact output connections. Hazardous potentials may exist on contact output terminals which are floating with respect to ins...
Section 3 – Installation Page 22 09/11/2008 REV 0.99 3.6 USB Connection There are two USB (Universal Serial Bus) Connectors on the rear panel. One is a Type A Master connector; the other is a Type B Slave connector. Only one can be active at any time – the active connector is selected by a slide swi...
Section 4 – Functional Description Page 24 09/11/2008 REV 0.99 4.0 FUNCTIONAL DESCRIPTION 4.1 Display Elements A Typical display on the recorder is shown above. The actual content of the window will vary according to what has been set up by the user. The display has two parts to it - the Task Bar al...
Section 4 – Functional Description Page 25 09/11/2008 REV 0.99 Figure 4-2 Utility Setup Menu There are 5 button icons in the Task Bar. They vary according to the status of the recorder. They are from left to right: Utility Setup Menu Button – This button takes the user to the Utility Setup Menu . He...
Section 4 – Functional Description Page 27 09/11/2008 REV 0.99 4.3 Alarm, Event and Activity Logs While viewing a live display, pressing the Events button (left) on the task bar brings up the Event and Alarm logs as shown right. Each time this button is pressed it will move through a series of logs ...
Section 4 – Functional Description Page 28 09/11/2008 REV 0.99 4.5 Configuration Manager The Configuration Manager is entered from the System Admin Menu by pressing the icon shown at the right. This is a privileged option and allows the administrator to load, save or clear the configuration file. Th...
Section 4 – Functional Description Page 29 09/11/2008 REV 0.99 4.6 Sending Email Sending email can be done in two ways – initiated by the user or initiated by an alarm condition. The email settings have to first be set up in the System Setup menu. This is where the default recipient and routing info...
Section 4 – Functional Description Page 30 09/11/2008 REV 0.99 Figure 4-7 Log In 4.7 User Login If password protection is enabled , the user will have to log in to be able to use many of the functions of the recorder. There are various levels of protection and access to functions is based on user pr...
Section 4 – Functional Description Page 31 09/11/2008 REV 0.99 4.8.2 Background Color The background color is the default color for all screen inactive areas, (between widgets and around the edge of the screen). It can be set by pressing the “BackGround” button shown right and in Figure 4-8 above. T...
Section 4 – Functional Description Page 32 09/11/2008 REV 0.99 The following conditions for record on alarm must be met for a recording to start. Record Setup External Trigger checkbox is checked The trigger source is selected Digital Input Setup Digital Input set to Record and enabled (Must be same...
Section 4 – Functional Description Page 33 09/11/2008 REV 0.99 4.12 Annotating Trends At any time while a live trend is visible, the user may annotate the chart by double tapping the point on the trend at which an annotation is to be added. This will pop up a small window as shown right which gives ...
Section 4 – Functional Description Page 34 09/11/2008 REV 0.99 screen To draw on the screen, select the pen color as detailed above then, using the stylus, draw on the screen. Add any text in the text box and place it on the screen using the place text icon as detailed above. This allows the user to...
Section 4 – Functional Description Page 35 09/11/2008 REV 0.99 Figure 4-13.4 Zoom with point markers Figure 4-13.5 Compress no point markers. Figure 4-13.3 Trace Setup Markers Off – Tapping this icon will remove the markers from the traces. This icon will only be visible if the markers are currently...
Section 4 – Functional Description Page 36 09/11/2008 REV 0.99 4.13.2 View Memos and Bitmaps At any time in the browse window, when an embedded memo or bitmap flag is visible, the respective memo or bitmap can be viewed by tapping the envelope icon ONCE . Note that double tapping the screen will go ...
Section 4 – Functional Description Page 37 09/11/2008 REV 0.99 4.13.4 Using Browser Jump To Future feature. 4.14 Browsing Annotations It is possible to view attached messages and bitmaps directly from the live trend window by double tapping anywhere on the trend. This will bring up the Browse/Annota...
Section 5 – Recorder Setup Page 38 09/11/2008 REV 0.99 5.0 RECORDER SETUP The recorder can be fully customized and needs to be set up by the user. The setup is saved in configuration files , which can be saved and loaded by the user. Several configurations are shipped with the unit and can be used a...
Section 5 – Recorder Setup Page 39 09/11/2008 REV 0.99 5.1.2 Channel Setup Pressing the edit button from the Master Channel Setup window takes you to the Channel Setup dialog window as shown in Figure 5-2. The user can copy an existing channel to this one or set up a new channel including the channe...
Section 5 – Recorder Setup Page 40 09/11/2008 REV 0.99 Figure 5-3 Linear Input Setup 5.1.3 Channel Type Setup The Channel Type Setup dialog window is dependent upon the type of input selected in the Channel Setup window above . 5.1.3.1 Linear Input For Linear Voltage and Current the dialog box is sh...
Section 5 – Recorder Setup Page 41 09/11/2008 REV 0.99 The resistor (or load) is connected like a 3 wire RTD – See Section 3.0 Installation . Use the Output Low and High to scale the resistance to the engineering unit of choice. 5.1.3.3 Industrial Square Root Extraction The recorder accepts the same...
Section 5 – Recorder Setup Page 42 09/11/2008 REV 0.99 5.1.3.5 Calculated Input Any of the eighteen channels can be a calculated channel. A calculated channel gets its value from a series of calculations, which may be based on one or more live channels. Setting a live input channel to be a calculate...
Section 5 – Recorder Setup Page 44 09/11/2008 REV 0.99 Figure 5-9 Gated Timer Setup 5.1.3.6 Conditional Input Any of the eighteen channels can be a conditional channel. A conditional channel gets its value from a true or false test of conditions which may be based on a live channel. Setting a live i...
Section 5 – Recorder Setup Page 45 09/11/2008 REV 0.99 Figure 5-10 Totalizer Setup Ext. Reset Enable: This is the External Reset. If this box is checked the timer will be reset by an external event via the digital inputs Note: an optional digital I/O card must be present in the system AND the design...
Section 5 – Recorder Setup Page 46 09/11/2008 REV 0.99 Figure 5-12 Frequency Setup Reset Intrvl: This is the Reset Interval. This is the time in days, hours, minutes and seconds between total resets when Auto Reset is checked. The example above will reset the Total every 5 minutes. Reset Sync: If th...
Section 5 – Recorder Setup Page 47 09/11/2008 REV 0.99 Calculator: This will bring up a calculator that allows computations to calculate the scaling factors. 5.1.3.9.2 Pulse Count Select Pulse Count from the setup menu. The options for Input and Output scaling and Negative Edge Triggering are as abo...
Section 5 – Recorder Setup Page 48 09/11/2008 REV 0.99 Reset Print: When this box is checked each time the total is reset, the information will b e appended to the alarm/event log (time and total). Total Reset on Alarm: – If checked the Total will be reset by the Alarm condition selected. In this ca...
Section 5 – Recorder Setup Page 49 09/11/2008 REV 0.99 5.2 Display Builder The Display Builder allows the user to customize the Graphical User Interface (GUI) or display screen using widgets to display data in various ways. The standard display on the recorder is shown on the right and consists of t...
Section 5 – Recorder Setup Page 50 09/11/2008 REV 0.99 Figure 5-2-3 Display Builder Widgets are selected as follows: Place Digital display either full size (2x2) or half size (2x1). Place Bar Graphs - horizontal full (6x1) or half (3x1) or vertical full (1x8) or half (1x4). Place Trends - horizontal...
Section 5 – Recorder Setup Page 51 09/11/2008 REV 0.99 Figure 5-2-4 Rotate List Setup 5.2.3 Rotate List The Rotate List allows the user to decide which display views will be active. Under normal viewing conditions, the user can rotate through the displays by pressing anywhere on the Task Bar where t...
Section 5 – Recorder Setup Page 52 09/11/2008 REV 0.99 5.3 Widgets A widget is a graphic element that a user interacts with or is used to build graphical user interfaces or GUIs. In the case of the recorder, the user constructs a GUI using the Display Builder using widgets. There are two basic types...
Section 5 – Recorder Setup Page 53 09/11/2008 REV 0.99 Alarms: When the Active box is checked the alarms are active for this channel (2) provided the Master Enable is set. When not checked the alarms are deactivated for this channel. Pressing the Alarms button opens the Alarm Setup dialog window. Th...
Section 5 – Recorder Setup Page 55 09/11/2008 REV 0.99 Scale: This is used to customize the local scale on the Bar Chart widget. In the above example, the input is a J Type Thermocouple which has an actual scale of -346 to 2192 °F. For this bar chart it has been set to 0 to 150 to show more detail a...
Section 5 – Recorder Setup Page 57 09/11/2008 REV 0.99 Figure 5-3-4 Trend Scale Setup 5.3.2.2 Trend Setup Trend setup can be done from the Display Builder or can be edited at any time by double- tapping the scale of the Trend display. Double- tapping the Trend display scale will pop up the Trend Sca...
Section 5 – Recorder Setup Page 59 09/11/2008 REV 0.99 5.4 Alarms A total of five Alarms can be set for each channel programmed. These five Alarms can be any combination of numerous Alarm types (limits). The Alarm dead band (also known as hysteresis) and Alarm delay can also be programmed for each A...
Section 5 – Recorder Setup Page 60 09/11/2008 REV 0.99 Alarms will also activate relay outputs if this option is installed and set up. See Section 5.5 Digital Input/Output for details. 5.4.1 Alarm Master Setup A larm setup can be done through the Alarm Master Setup or can be done on an “as you go” b...
Section 5 – Recorder Setup Page 62 09/11/2008 REV 0.99 Event Message: Enter a message in the entry box (up to a maximum of 20 characters) that will be appended to the alarm/event log message if the check box to the left is checked. This message will also be appended to the email if the notify box is...
Section 5 – Recorder Setup Page 63 09/11/2008 REV 0.99 Figure 5-5-1 Digital Output Setup 5.5.1 Digital Output Setup To access the Digital Output Setup dialog window: Press the Utility Setup Menu icon on the bottom left of the Task Bar. Then Press the Digital I/O Setup icon which will bring up the di...
Section 5 – Recorder Setup Page 64 09/11/2008 REV 0.99 5.5.2 Digital Input Setup To access the Digital Input Setup dialog window: Press the Utility Setup Menu icon on the bottom left of the Task Bar. Press the Digital I/O Setup icon (left) and then select Digital Input button (below left) to launch ...
Section 5 – Recorder Setup Page 66 09/11/2008 REV 0.99 5.6 Record Setup There are several ways to start a recording. The recording can be started manually by the user, by an external event , by an alarm event or on a time schedule. Each of these methods has to be enabled in the record setup as well ...
Section 5 – Recorder Setup Page 67 09/11/2008 REV 0.99 5.6.2 Media and Filename Media: Select the media and file name to record to. Choices are: CF Card which is the Compact Flash card and is the recommended removable media. Internal Memory is the optional internal Secure Digital Card. It is eff...
Section 5 – Recorder Setup Page 69 09/11/2008 REV 0.99 5.6.8 Media Alarm The media alarm can be used to alert the user that the media is nearing capacity and needs to be exchanged. The alarm needs to be setup before the enable checkbox is checked. The setup of the media alarms is similar to the setu...
Section 5 – Recorder Setup Page 70 09/11/2008 REV 0.99 5.7 System Administrative Menu The Administrative Menu is entered from the Utility Setup Menu by pressing the icon shown at the right. This is a privileged option and will pop-up a new set of icons as shown below: The icons have the following fu...
Section 5 – Recorder Setup Page 71 09/11/2008 REV 0.99 Web User Management – Allows the administrator to add or remove web users. Details Here Email Setup – Allows the administrator to set up email parameters. Details Here Set ActiveSync Password – Allows the administrator to set the password for US...
Section 5 – Recorder Setup Page 72 09/11/2008 REV 0.99 Fig 5.7.2 – System Setup 5.7.1 Temperature Compensation This is the Ambient Temperature Compensation adjust and is used to compensate for adverse environments when using thermocouples. This feature is entered from the system admin menu by pressi...
Section 5 – Recorder Setup Page 73 09/11/2008 REV 0.99 5.7.2.2 Modbus Settings This is only applicable if the serial port option is installed in the unit. Modbus is a communication protocol which runs over RS232 (single unit) or RS485 (multiple units). The ID uniquely identifie s the device in a mul...
Section 5 – Recorder Setup Page 74 09/11/2008 REV 0.99 To change the year – tap on it pull down iconwhich will pop up a calendar. Scroll through and select the current date. Select the required date format from the pull down menu – mm/dd/yyyy or dd/mm/yyyy. The time can be shown in 12 or 24 hour (mi...
Section 5 – Recorder Setup Page 75 09/11/2008 REV 0.99 Activity Log: Check this box to enable the Activity Log – this option tracks all changes made by a user and is useful for FDA compliance. Use the Exhibitor Software to print Activity Log reports. Add: Once user, password, and other parameters ar...
Section 5 – Recorder Setup Page 76 09/11/2008 REV 0.99 5.7.6 Network Settings Tapping the Ethernet IP Address Setting icon in the System Admin Menu (left) will bring up the Network IP Address dialog window. If you wish to specify an IP address, enter the information in the IP, Subnet and Gateway tex...
Section 5 – Recorder Setup Page 77 09/11/2008 REV 0.99 5.7.8 SMTP Email Settings This allows the administrator to set up the email. This feature is entered from the system admin menu by pressing the icon shown right SMTP is Simple Mail Transfer Protocol and is the standard for email transmission acr...
Section 5 – Recorder Setup Page 78 09/11/2008 REV 0.99 5.7.10 Registry The Registry option allows the user to clear or save the registry. The Registry holds system base setup values not in the configuration file and needs to be saved if system setup changes have been made – for example recalibrating...
Section 5 – Recorder Setup Page 79 09/11/2008 REV 0.99 Figure 5.7.11 – Language Screen 5.7.11 Languages The languages option allows the users to customize the unit language for the local country by loading preconfigured language files. This feature is entered from the system admin menu by pressing t...
Section 6 - Communication Page 81 09/11/2008 REV 0.99 6.0 COMMUNICATION There are various ways to communicate remotely with the recorder. The Ethernet port can be used to communicate on a network or via the World Wide Web (Both HTTP and FTP protocols). There are various means of doing this as simply...
Section 6 - Communication Page 83 09/11/2008 REV 0.99 6.2 Web Based FTP Manager The “File Manager” Button brings up the FTP launch window. Note that you need internet access to run the FTP File Manager and the Java Engine must be present. Click the big button to proceed. If internet access is not av...
Section 6 - Communication Page 85 09/11/2008 REV 0.99 10. This is the connection to the Java web site to allow download of the Java Engine that runs thi s program. It may be the only thing you see if Java is not installed. The FTP Manager allows for file manipulation between the local PC (computer) ...
Section 6 - Communication Page 86 09/11/2008 REV 0.99 6.3 Ethernet Protocols 6.3.1 OPC Server The Recorder supports The OPC Standard (Open Connectivity over Open Standards). It is a standard u sed to move real-time data from PLCs, DCSs, and other control devices to HMIs and other display clients. Th...
Section 6 - Communication Page 87 09/11/2008 REV 0.99 6.3.2 Modbus Server The recorder supports Modbus TM RTU (Remote Terminal Unit) over Ethernet and optional RS485 interfaces. An RS485 interface will support up to 64 Data Recorders linked to a single computer. Each of the Recorders will be identif...
Section 6 - Communication Page 88 09/11/2008 REV 0.99 Table 6.3.2.2 Holding Registers 4xxx (Use Function 3 to Access) 32 Bits Modicon TM Format Floating Point Writing to these registers has no effect Register # FUNCTION AND STATE Register # FUNCTION AND STATE 4361 Point 1 Data Low Word 4379 Point 10...
Section 6 - Communication Page 89 09/11/2008 REV 0.99 6.4 USB Connections The recorder can communicate via the rear USB Type B Slave port to a PC running Windows XP and Microsoft‟s ActiveSync™ which can be downloaded from the Microsoft Website at http://www.microsoft.com/windowsmobile/activesync/act...
Section 6 - Communication Page 90 09/11/2008 REV 0.99 6.5 Utility Programs The utility programs provide a method of communicating with the recorder to move data or control operation remotely. The programs are on the CD that came with the unit. To install the programs, insert the CD in the Drive (Win...
Section 6 - Communication Page 91 09/11/2008 REV 0.99 The program is launched from the desktop icon shown right or from the programs menu. The program launches the window below: The red numbers are for reference only. The software is intended for use with the recorders only – it is specific to this ...
Section 6 - Communication Page 93 09/11/2008 REV 0.99 6.5.2 Remote Control There are two remote control programs available for controlling the recorder over the Ethernet. Remote Display is recommended if you are on the same network as the recorder. Remote Manager allows control of the recorder over ...
Section 6 - Communication Page 94 09/11/2008 REV 0.99 6.5.2.2 Remote Manager The Remote Manager program is installed from the software installation disk that came with the recorder. This program will run on a W AN (Wide Area Network) – over the Ethernet and will work through a Firewall if the firewa...
Section 7 - Instrument Care and Maintenance Page 95 09/11/2008 REV 0.99 7.0 INSTRUMENT CARE AND MAINTENANCE 7.1 Touch Screen Care should be taken with the touch screen when handling the unit. Sharp and hard objects may pierce the touch screen and damage the display. Only use the stylus provided for ...
Section 7 - Instrument Care and Maintenance Page 96 09/11/2008 REV 0.99 for each channel . Current Cal RTD – Calibrate the unit‟s current excitation source. Apply a 250 Ohm precision resistor. Doing this on one channel calibrates all channels. 1 Hz Cal – Calibrate the units frequency reference. Appl...
Section 7 - Instrument Care and Maintenance Page 97 09/11/2008 REV 0.99 one channel calibrates all channels. Accept the “Calibration Function OK” popup dialog. To calibrate another range repeat from step 6.3.1.3. Calibrate all or as many ranges as you need. 7.3.1.4 Store Cal Once all the required ra...
Section 7 - Instrument Care and Maintenance Page 98 09/11/2008 REV 0.99 Select the channel to use in the Channel drop down menu box (1, 6, 7 or 12) and select “1 Hz Cal” in the Calibration Function drop down menu box. The Range does not matter. P ress the “Set Chan” button. A “Channel has been set s...
Appendix A - Technical Specifications Page 99 09/11/2008 REV 0.99 APPENDIX A – TECHNICAL SPECIFICATIONS DISPLAY Display Type Color CCFL backlit Active Matrix TFT Liquid Crystal Display (5.6 inch) QVGA with resistive analog touch screen control. Resolution Color 320 (H) X 234 (V) pixels. Display Mode...
Appendix A - Technical Specifications Page 100 09/11/2008 REV 0.99 Thermocouple : Per ITS90 Resolution 0.1°C Thermocouple burnout detection - automatic Type Range (°C) Accuracy (°C) Range (°F) Accuracy (°F) J -210 to -100 °C ±2.5 °C -340 to -150 °F ±5 °F -100 to 1200 °C ±1.5 °C -150 to 2190 °F ±3 °F...
Appendix A - Technical Specifications Page 101 09/11/2008 REV 0.99 RECORDING Recording Rates User programmable from 10 samples per second to 1 sample every 99 hours. Data Format Proprietary encrypted format. User File naming. Data Storage Capacity Data stored in non-volatile RAM and recorded automat...
Appendix B – Digital Input Voltage Adjustment Page 102 09/11/2008 REV 0.99 APPENDIX B – DIGITAL INPUT VOLTAGE ADJUSTMENT WARNING TO ELIMINATE THE RISK OF SHOCK ENSURE THAT THE MAINS CABLE AND ALL CONNECTORS ARE REMOVED FROM THE RECORDER BEFORE PROCEEDING. B.1 ANALOG MODULE: The analog input module a...
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 25 months from date of purchase. OMEGA Warranty adds an additional one (1) month graceperiod to the normal two (2) years product warranty to cover handling and shipping ti...
Omega Manuals
-
Omega DP119-RTD
Manual
-
Omega K9-5Classic
Manual
-
Omega OFS30
Manual
-
Omega LV860
Manual
-
Omega DPG3500
Manual
-
Omega DP6-MLPS1
Manual
-
Omega FTB600B
Manual
-
Omega 3200
Manual
-
Omega HCTB-3020
Manual
-
Omega 8004/8006
Manual
-
Omega FP-6000
Manual
-
Omega CO-BR130
Manual
-
Omega HH806W
Manual
-
Omega OMA-P1104
Manual
-
Omega HH308
Manual
-
Omega CNiS16D
Manual
-
Omega CN8260
Manual
-
Omega 25
Manual
-
Omega OS561
Manual
-
Omega OS643-LS
Manual