Page 2 - One Omega Drive, River Bend Technology Centre; OMEGAnet
Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technical o...
Page 3 - Contents
Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ...........................................................................
Page 4 - Figures
F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT ............ 14 EMC D IRECTIVE S TATEMENT ........................................................... 14 Figures Figure 1 - Clocking Mode ‘Divide By 4’ ............................................................ 2 Figure 2 - Clocking Mode ‘Divide By 1...
Page 5 - Introduction; Overview
Introduction OMG-COMM8 -PCI Page 1 Introduction Overview The OMG-COMM8 -PCI provides the PC with eight RS-232 asynchronous ports. The OMG-COMM8 -PCI allows for connection to any device utilizing the RS-232 electrical interface, such as modems, data-entry terminals, and plotters. What’s Included The ...
Page 6 - Card Setup; Clock Modes
Card Setup OMG-COMM8 -PCI Page 2 Card Setup Clock Modes The OMG-COMM8 -PCI employs a unique clocking option that allows the end user to select from divide by 4 and divide by 1 clocking modes. This mode is selected at J1. To select the Baud rates commonly associated with COM: ports (i.e. 2400, 4800, ...
Page 7 - Baud Rates and Divisors for the ‘Div1’ mode; For this Data Rate; Address and IRQ selection
Card Setup OMG-COMM8 -PCI Page 3 Baud Rates and Divisors for the ‘Div1’ mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the ‘Div1’ mode. For this Data Rate Choose thi s Data Rate 1200 bps 300 bps 2400 bps 600 bps 4800 bps 12...
Page 8 - Installation; Operating System Installation; Install Software at the beginning of the CD. Choose; Other Operating Systems
Installation OMG-COMM8 -PCI Page 4 Installation Operating System Installation For Windows Users Start by choosing Install Software at the beginning of the CD. Choose Asynchronous COM: Port Software, SeaCOM. Other Operating Systems Refer to the appropriate section of the Serial Utilities Software. Sy...
Page 9 - Technical Description; Connector Pin Assignments
Technical Description OMG-COMM8 -PCI Page 5 Technical Description The OMG-COMM8 -PCI utilizes the 16C554 UART. This chip features programmable baud rate, data format, interrupt control and a 16-byte input and output FIFO, and is functionally 4 16C550 UARTs. A full array of advanced UARTS is also ava...
Page 11 - Specifications; Environmental Specifications
Specifications OMG-COMM8 -PCI Page 7 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) -20º to 70º C (-4º to 158º F) Humidity Range 10 to 90% R.H. Non-Condensing 10 to 90% R.H. Non-Condensing Power Consumption Supply line +12 VD...
Page 12 - Appendix A - Troubleshooting
Appendix A - Troubleshooting OMG-COMM8 -PCI Page 8 Appendix A - Troubleshooting Serial Utility test software is supplied with the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the ne...
Page 13 - PCI COM NUMBER SELECTION IN WINDOWS 95
Appendix A - Troubleshooting OMG-COMM8 -PCI Page 9 PCI COM NUMBER SELECTION IN WINDOWS 95 When installing a multi-port PCI card in Windows 95 the default starting COM: number assigned to the first port will be COM:5 if no COM:5 exists. If there is a COM: 5, 6, etc., the next available COM: number wi...
Page 14 - Appendix B - How To Get Assistance
Appendix B - How To Get Assistance OMG-COMM8 -PCI Page 10 Appendix B - How To Get Assistance Please refer to Troubleshooting Guide prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system. 2. When calling for technical assistance, ple...
Page 15 - Appendix C - Electrical Interface; DTE
Appendix C - Electrical Interface OMG-COMM8 -PCI Page 11 Appendix C - Electrical Interface RS-232 Quit e possibly the most widely used communication standard is RS-232. This implementation has been defined and revised several times and is often referred to as RS-232-C/D/E or EIA/TIA -232-C/D/E. It i...
Page 16 - Appendix D - Asynchronous Communications
Appendix D - Asynchronous Communications OMG-COMM8 -PCI Page 12 Appendix D - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handsh...
Page 18 - Appendix F - Compliance Notices; Federal Communications Commission Statement; Warning
Appendix F - Compliance Notices OMG-COMM8 -PCI Page 14 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to p...
Page 19 - RETURN REQUESTS/INQUIRIES; WARRANTY
WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping...