Page 2 - One Omega Drive, River Bend Technology Centre; OMEGAnet
Servicing North America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technic...
Page 3 - Specifications and Calibration
Warnings, Cautions, Notes, and Tips Refer all service to qualified personnel. This symbol warns of possible personal injury or equipment damage under noted conditions. Follow all safety standards of professional practice and the recommendations in this manual. Using this equipment in ways other than...
Page 4 - CAUTION; Windows
iv Your order was carefully inspected prior to shipment. When you receive your order, carefully unpack all items from the shipping carton and check for physical signs of damage that may have occurred during shipment. Promptly report any damage to the shipping agent and your sales representative. Ret...
Page 5 - Manual Layout; . Explains what DaqTemps are, the differences between; Reference Note
DaqTemp Series User’s Manual 10-14-02 v Manual Layout Chapter 1 – Overview and Theory of Operation . Explains what DaqTemps are, the differences between the four DaqTemp models, and discusses certain aspects of data acquisition in relation to DaqTemp,as well as the theory of operation for each DaqTe...
Page 7 - Table of Contents; Overview
DaqTemp Series User’s Manual 10-14-02 vii Table of Contents 1 – Overview and Theory of Operation Features and General Information ……1-1Scanning….1-5Triggering …… 1-6Theory of Operation …… 1-7 2 – How to Install DaqTemp Step 1 – Install Software …… 2-2Step 2 – Install the DaqTemp PCI Board …… 2-2Step...
Page 9 - Overview and Theory of Operation; Features and General Information ...... 1-1; Features and General Information; DaqTemp’s Three Hardware Components
DaqTemp User’s Manual 09-06-02 Overview & Theory of Operation 1-1 Overview and Theory of Operation 1 Features and General Information …… 1-1 Scanning…… 1-5Triggering …… 1-6Theory of Operation …… 1-7 Features and General Information DaqTemps are reliable, accurate, and compact data acquisition so...
Page 10 - Thermocouple Channels (; DaqTemp7; and; DaqTemp7A; Thermocouple Channel Connections for; Note; When in this mode, voltage can be measured in the range of ±100 mV.
1-2 Overview & Theory of Operation 09-06-02 DaqTemp User’s Manual Thermocouple Channels ( CH1 - CH7, CH9 - CH15 ) Each DaqTemp features on-board cold junction compensation (CJC) for direct measurement of type J,K, T, E, N28, N14, S, R, and B thermocouples. The following table provides the temper...
Page 11 - Differential Input Channels (; Analog I/O Section of DaqTemp
DaqTemp User’s Manual 09-06-02 Overview & Theory of Operation 1-3 Differential Input Channels ( 1H / 1L - 7H / 7L ) Each DaqTemp model has seven differential input channels for measuring voltage. The voltage channelsare labeled from 1H / 1L to 7H / 7L, with the “H” and “L” representing channel h...
Page 12 - Digital I/O Section of DaqTemp Digital and Analog I/O Card; Frequency/Counter Inputs
1-4 Overview & Theory of Operation 09-06-02 DaqTemp User’s Manual 24-Bit, General Purpose Digital I/O ( Channels A0 - A7, B0 - B7, and C0 - C7 ) All DaqTemps have 24-bit, general purpose, digital I/O that can be used to directly control and monitor24 digital I/O lines. The 24-bit digital I/O is ...
Page 13 - Scanning; DaqTemp Scanning Example
DaqTemp User’s Manual 09-06-02 Overview & Theory of Operation 1-5 Scanning Every DaqTemp has an on-board scan sequencer that permits the user to select any combination of up to512 channel/range combinations. The sequencer scans all channels contained in the sequence at the rate of5 µs/channel, t...
Page 14 - Triggering; Hardware Analog Triggering; . The DaqTemp PCI Board also supports digital pattern triggering,; Counter Triggering; This, the simplest of modes, acquires data upon receipt of the
1-6 Overview & Theory of Operation 09-06-02 DaqTemp User’s Manual Triggering Triggering can be the most critical aspect of acquiring data. The DaqTemp PCI Board supports a fullcomplement of trigger modes to accommodate a wide variety of applications. Hardware Analog Triggering . Many data acquis...
Page 15 - Variable pre-trigger with post trigger stop event; Theory of Operation; I/O Comparison Matrix; Synchronous Input Operations
DaqTemp User’s Manual 09-06-02 Overview & Theory of Operation 1-7 • Variable pre-trigger with post trigger stop event (driver support only). Unlike the previous pre- trigger modes, this mode does not have to satisfy the pre-trigger number of readings beforerecognizing the trigger event. Thus the...
Page 16 - Analog Input Channels; Channel Selection and Mode Settings; The DaqTemp module accepts up to 7 differential inputs.; Channel Range and Polarity; Digital Input Channels; Synchronous Output Operations
1-8 Overview & Theory of Operation 09-06-02 DaqTemp User’s Manual Analog Input Channels The DaqTemp Series PCI Boards allow analog input configuration for the voltage input channels and thethermocouple input channels. Channel Selection and Mode Settings The DaqTemp module accepts up to 7 differe...
Page 17 - Output Channel Configuration; Clear on Read Mode
DaqTemp User’s Manual 09-06-02 Overview & Theory of Operation 1-9 Output Channel Configuration Analog Output Channels Each D/A channel can be configured for waveform output individually. If the D/A channel is notconfigured for waveform output, it then is available for asynchronous output operati...
Page 18 - Operation Matrix; Operation; DaqTemp7 and; Synchronous Input; Block Diagram; DaqTemp PCI Board Block Diagram
1-10 Overview & Theory of Operation 09-06-02 DaqTemp User’s Manual Operation Matrix Operation DaqTemp7A PCI Board DaqTemp14A PCI Board DaqTemp7 and DaqTemp14 PCI Board Synchronous Input Analog Inputs Yes Yes Yes Counter Inputs Yes Yes Yes Digital Inputs Yes Yes Yes Synchronous Output Analog D/A ...
Page 21 - How to Install DaqTemp; DaqTemp Module Serial Number; DaqTemp Installation, A Pictorial Overview
DaqTemp User’s Manual 10-14-02 How to Install DaqTemp 2-1 How to Install DaqTemp 2 Step 1 – Install Software …… 2-2Step 2 – Install the DaqTemp PCI Board …… 2-2Step 3 – Configure the PCI Board ….. 2-4Step 4 – Test the PCI Board ….. 2-5Step 5 – Connect the DaqTemp Module to its associated PCI Board …...
Page 22 - Install Software; Place the Data Acquisition CD into the CD-ROM drive.; Step 2; Install the DaqTemp PCI Board; Software must be installed before installing hardware.; Enabled; must be; Turn
2-2 How to Install DaqTemp 10-14-02 DaqTemp User’s Manual Step 1 – Install Software IMPORTANT: Software must be installed before installing hardware. 1. Remove previous version Daq drivers, if present. You can do this through Microsoft’s Add/Remove Programs feature. 2. Place the Data Acquisition CD ...
Page 23 - Removing a Blank Adapter Plate from
DaqTemp User’s Manual 10-14-02 How to Install DaqTemp 2-3 5. On the PC’s rear panel, loosen and remove the screw for the blank adapter plate that corresponds withthe chosen PCI bus. See the following figure. Removing a Blank Adapter Plate from the Host Computer’s Rear Panel (Steps 5 and 6) 6. Remove...
Page 24 - Configure the DaqTemp PCI Board; Configuring DaqTemp via the Properties Tab
2-4 How to Install DaqTemp 10-21-02 DaqTemp User’s Manual Step 3 – Configure the DaqTemp PCI Board DaqTemp PCI boards have no jumpers or switches to set. Configuration is performed, in its entirety,through software. Refer to the following figure and steps to complete the configuration. 1. Run the Da...
Page 25 - Using “Add Device”; Select Device Type; Test the DaqTemp PCI Board; Test Hardware Tab
DaqTemp User’s Manual 10-14-02 How to Install DaqTemp 2-5 Using “Add Device” This method is for users who have accessed the Daq Configuration control panel applet, but have no DaqTemp icon. (A) After accessing the Daq Configuration controlpanel applet, click on the Add Device button (seefigure, righ...
Page 26 - Connect the DaqTemp Module to its PCI Board; Connecting the DaqTemp Module to the PCI Board; that are being mated.
2-6 How to Install DaqTemp 10-14-02 DaqTemp User’s Manual Step 5 – Connect the DaqTemp Module to its PCI Board Connecting the DaqTemp Module to the PCI Board CAUTION CAUTION CAUTION CAUTION Turn off power to and unplug the host PC prior to connecting the DaqTemp tothe computer. Failure to do so coul...
Page 27 - Making Signal Connections; Connect the signal lines to the intended terminals on DaqTemp’s
DaqTemp User’s Manual 09-03-02 Making Signal Connections 3-1 Making Signal Connections 3 Connect the signal lines to the intended terminals on DaqTemp’s card-mounted terminal blocks for Digital or Analog I/O, and/or to the chassis-mounted terminal blocks for thermocouple connections. In regard to th...
Page 28 - plane; Open Thermocouple Detection
3-2 Making Signal Connections 09-03-02 DaqTemp User’s Manual For isothermal performance, an exposed, grounded copper plane surrounds the inputconnectors. It is important that non-insulated input wires do not contact the grounded plane −−−− since such contact can degrade measurement integrity. It sho...
Page 29 - Software for DaqTemp Applications; DaqView, Channel Setup Tab Selected; DaqView; The; allows for interface configuration, testing, and
DaqTemp User’s Manual 10-14-02 Software for DaqTemp Applications 4-1 Software for DaqTemp Applications 4 DaqView, Channel Setup Tab Selected DaqTemp devices are intended for use with two categories of software: (1) Ready-to-use graphical programs , also referred to as out-of-the-box programs. These ...
Page 30 - Omega
4-2 Software for DaqTemp Applications 10-14-02 DaqTemp User’s Manual Reference Note : During software installation, Adobe ® PDF versions of user manuals will automatically install onto your hard drive as a part of product support. The default location is in the Programs group, which can be accessed ...
Page 31 - CE-compliant products bear the “CE” mark and include a; Declaration of Conformity; stating the; CE Standards and Directives; Official Journal of European Union
DaqTemp Series User’s Manual 08-27-02 CE-Compliance 5-1 CE-Compliance 5 Overview ……5-1CE Standards and Directives …… 5-1Safety Conditions ……5-2Emissions/Immunity Conditions ……5-2CE Cable Kit for DaqTemps…… 5-3 Overview CE-compliant products bear the “CE” mark and include a Declaration of Conformity ...
Page 32 - pollution degree; Safety Conditions
5-2 CE-Compliance 08-27-02 DaqTemp Series User’s Manual For clarification, terms used in some Declarations of Conformity include: • pollution degree : any addition of foreign matter, solid, liquid or gaseous (ionized gases) that may produce a reduction of dielectric strength or surface resistivity. ...
Page 33 - CE Cable Kit for DaqTemps; Remove the DaqTemp Series Board from the Host PC; Turn the host PC’s power; OFF; power OFF; to externally connected equipment.; UNPLUG the host PC; and all externally connected equipment.; Install the CE ORB; Mounting a DaqTemp Series PCI Board to a CE ORB
DaqTemp Series User’s Manual 08-27-02 CE-Compliance 5-3 CE Cable Kit for DaqTemps CAUTION CAUTION CAUTION CAUTION Turn OFF the power to, and UNPLUG the host PC and externally connected equipment prior toremoving the PC’s cover and removing (or installing) the DaqTemp Series PCI Board. Electricshock ...
Page 34 - Install the DaqTemp PCI Board with its CE ORB; off; and externally
5-4 CE-Compliance 08-27-02 DaqTemp Series User’s Manual Install the DaqTemp PCI Board with its CE ORB If you are installing the DaqTemp Series Board for the first time, refer to chapter 2 of this manual, How to Install DaqTemp . 1. If you have not already done so , turn off power to, and UNPLUG the ...
Page 35 - Connect the CA-195CE Cable to the Board; the white locator triangles must align with each other; : In the right hand figure, the cable is not shown to; Secure the Grounding Pigtail to Cable CA-195CE
DaqTemp Series User’s Manual 08-27-02 CE-Compliance 5-5 Connect the CA-195CE Cable to the Board 1. Connect one end of the CA-195CE Cable to DaqBoard/2000 Series Board’sP4 connector. Note that either end of the cable can be connected to theboard; however, the white locator triangles must align with e...
Page 36 - Connect Cable and Grounding Pigtail to the DaqTemp Module; Complete the connection.; DaqTemp Module
5-6 CE-Compliance 08-27-02 DaqTemp Series User’s Manual Connect Cable and Grounding Pigtail to the DaqTemp Module 1. Verify that the P4 connectors of the CA-195CE Cable and the DaqTemp Module arecorrectly aligned. Correct alignment is indicated when the P4 locator triangles faceeach other (see figur...
Page 37 - Calibration; DaqCal
DaqTemp User’s Manual 10-14-02 Calibration 6-1 Calibration 6 Overview …… 6-1Using DaqCal.exe …… 6-1 Overview DaqTemp PCI Boards are digitally calibrated at the factory. The digital method involves storing acorrection factor for each range [on the DaqTemp PCI Board] at the time of calibration. Whenev...
Page 38 - System Calibration and Unit Conversion Using mx + b
6-2 Calibration 10-14-02 DaqTemp User’s Manual Reference Note : If the ambient temperature of the operating environment is below 18 ° C or above 28 ° C, or if the DaqTemp is near or outside its one-year calibration interval, then the absolute accuracymay be improved through the use of an external te...
Page 39 - Specifications; General; Successive approximation; Voltage Inputs; us to 1 LSB for full-scale step
DaqTemp User’s Manual 09-04-02 Specifications 7-1 Specifications 7 There are currently four different models of DaqTemp, as indicated by the following table. Each DaqTemp includes a signalconnection module, a 3 foot cable, a DaqTemp PCI plug-in board, DaqView software, and drivers for DASYLab, LabVI...
Page 40 - Common Mode Rejection:; 1V relative to analog common; Thermocouple Inputs; or 14 differential TC/mV inputs; Over Voltage Protection:; deg C for all TC types; TC Accuracy at Measurement Temperature in °C (±°C)
7-2 Specifications 09-04-02 DaqTemp User’s Manual Common Mode Rejection: 86 dB, DC to 60 Hz for gains < =8; >100 dB for gains > =16 Maximum Input Voltage: ± 11V relative to analog common Over-Voltage Protection: ± 35V Ranges: Software or sequencer selectable on a per-channel basis, from 156...
Page 41 - Programmable Parameters per Scan:; Minimum Pulse Width:
DaqTemp User’s Manual 09-04-02 Specifications 7-3 Input Sequencer Temperature, voltage, digital and frequency inputs can be scanned synchronously, based on either an internal programmabletimer, or an external clock source. Analog and digital outputs can be synchronized to either of these clocks. Bus...
Page 42 - NNE
7-4 Specifications 09-04-02 DaqTemp User’s Manual For DaqTemp7A and DaqTemp14A, analog output channels can be updated synchronously relative to scanned inputs, andclocked from either an internal onboard clock, or an external clock source. Analog outputs can also be updatedasynchronously, independent...
Page 43 - Software; CE Compliance
DaqTemp User’s Manual 09-04-02 Specifications 7-5 Software The following software is included with DaqTemp: DaqView, Windows drivers for Visual Basic and C++, and drivers forLabVIEW and DASYLab. An optional software application, DaqView XL, provides a direct link from DaqView to Excel spreadsheets. ...
Page 45 - Glossary
Glossary 08-23-02 G-1 Glossary Acquisition A collection of scans acquired at a specified rate as controlled by the sequencer. Analog A signal of varying voltage or current that communicates data. Analog-to-Digital Converter (ADC) A circuit or device that converts analog values into digital values, s...
Page 46 - isolated
G-2 08-23-02 Glossary Digital-to-Analog Converter (DAC) A circuit or device that converts digital values (binary bits), into analog signals. DIP switch A DIP switch is a group of miniature switches in a small Dual In-line Package (DIP). Typically, users set these switches to configure their particul...
Page 47 - Trigger
Glossary 08-23-02 G-3 Trigger An event to start a scan or mark an instant during an acquisition. The event can be defined in various ways; e.g., a TTL signal, a specified voltage level in a monitored channel, a buttonmanually or mechanically engaged, a software command, etc. Some applications may us...
Page 49 - consequential, incidental or special damages.; RETURN REQUESTS/INQUIRIES; WARRANTY
WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shippin...
Page 50 - Shop online at omega.com
M 3882 / 1205 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point R...