Page 4 - CONTENTS; Title page; Stop
CONTENTS Title page 1. SAFETY INFORMATION ................................................................................................ 1 2. SPECIFICATION ............................................................................................................. 2 2-1 General Specification .......
Page 6 - SAFETY INFORMATION; Environment conditions
1 1. SAFETY INFORMATION q Read the following safety information carefully before attempting to operate or service the meter. q The meter analog input protection voltage range is 24V , current range is 250V/0.5A Fuse(MAX) , maybe damage forever if overload. Environment conditions : Altitude up to 2...
Page 7 - -1 General Specification; Display; SET; In setting mode symbol.; DATE
2 2. SPECIFICATION 2-1 General Specification Display : 3 2 1 LCD LCD symbols : 1 3 4 2 26 5 6 7 24 18 19 11 28 17 20 22 27 25 9 14 23 10 21 13 12 15 16 8 (Fig-1) 1. SET : In setting mode symbol. 2. RS-232 : In RS-232 transmission mode symbol. DATE 3. – – : Show the date of real time clock.Show mode ...
Page 9 - 9 minute : 59
4 24. HI ALARM : Hi alarm indicator. 25. LO ALARM : Lo alarm indicator. 26. HiHi ALARM : Hi Hi alarm indicator. 27. LoLo ALARM : Lo Lo alarm indicator. 28. ℃ , ℉ : Temperature unit indicator. 29. Over Load Indicator : Show or - 。 Other parts : Input Protection : Voltage range 24V , current range 0.5...
Page 10 - -2 Electrical Specification
5 2-2 Electrical Specification Analog test range : DCV/ACV : 2V , 200mV DCA : 20mA Accuracy : (at 23 ℃± 5 ℃, below 80%RH) DC è ( ± 1%rdg+3dgts) AC è ( ± 1%rdg+5dgts) at (50~450Hz) Resolution : 200mV/2V range is 0.1mV/1mV 20mA range is 0.01mA A / D Sample Rate : 2.5 times/sec Power Source : 6 pcs 1.5...
Page 11 - -1 The Name of Each Parts and Positions:
6 3. PARTS & CONTROLS 3-1 The Name of Each Parts and Positions: PRINT 600V 60V24V MAX C O M V m A FUSED 20mA MAX FEED LINE MIN MAX UNIT RANGE 1 , 2 0 200mV 2V 200mV 2V 20mA C ¢X Fc Lux dB ¢ X ¢ X RH A A DATE TIME START STOP T G INTV HiHi Hi Lo LoLo TRIGGER 3 CONSECUTIVE , 3 , F ¢X SETTING 1 3 4 ...
Page 12 - INTV; SETUP
7 1. 200mV C / F HiHi DATA 0 Toggle button for ( 200mV, ℃ / ℉ , HiHi, DATA) and digit “ o ”. 2. 2V Lux/Fc Hi TIME 1/2/3 Toggle button for ( 2V, Lux/ Fc, Hi, TIME) and digit “ 1/2/3 ”. 3. 200mV dB LoLo START 4/5/6 Toggle button for ( 200mV, dB, LoLo, START) and digit “ 4/5/6 ”. 4. 2V %RH Lo STOP 7/8/...
Page 14 - DCV and DCA Test Setting :
9 3-2 Power Status : As battery power is not sufficient, the , will be shown on LCD replace with six new 1.5V batteries is required. 3-3 Quick Manual for Easy Set-up STEP1 STEP2 STEP3 STEP4 STEP5 Push thisbutton 3 second. Select one. Choose one from specified function Bar. Reconfirm input setting. P...
Page 15 - -5 UNIT Setting Step; dB; -6 ALARM Setting Step; ALARM
10 4. DCV 200mV Test setting sequence : Press and hold 3'SETTING for 3 sec à press RANGE à press 200mV à press RANGE à press 3'SETTING , to end setting mode. 5. DCA 20mA Test setting sequence : Press and hold 3'SETTING for 3 sec à press RANGE à press 20mA à press RANGE à press 3'SETTING , to end set...
Page 17 - START; STOP
12 press 3'SETTING to end setting mode. 3-9 Print Mode Setting Step : Printer work mode setting sequence : press and hold 3'SETTING for 3 sec into setting mode à press ALARM à press G/T change G/T MODE à press 3'SETTING , to end setting mode. 3-10 Clear Record Step : Press RECORD = + Power ON in the...
Page 18 - -15 Record / Print Start and Step Operation Method; or; or; The
13 3-15 Record / Print Start and Step Operation Method : (1). Start way : 1. Trigger Record / Print : in general mode press RECORD = or PRINT one second. 2. Consecutive Record/Print : Automatic mode : a). Into setting mode, setting Start/Stop/Into/Time.b). Chose automate consecutive Record/Print (...
Page 19 - -18 Scale Change in Graphic Mode
14 3-18 Scale Change in Graphic Mode HiHi ALARM Hi ALARM Lo ALARM LoLo ALARM Scale change by alarm setting ü No change ü No change ü No change ü No change ü ü Change scale by HiHi Hi ALARM ü ü Change scale by HiHi Lo ALARM ü ü Change scale by HiHi LoLo ALARM ü ü Change scale by Hi Lo ALARM ü ü Chang...
Page 20 - Model; terminal same
15 CONSECUTIVE , m A , 3 PRINT 1 CLOCK C O M MAX FUS ED 20mA 24V 600V MAX 60V RECORD ALARM TRIGGER V 1 SETTING Lux 3 SETUP 0 , HiHi DAT E ¢X 200mV ¢ X C F Lo STO P RH 2V RANGE LINE FEED 3 2 4 6 5 8 7 LoLo ST ART 200mV TIME Hi F c 2V dB ¢ X ¢X UNIT MAX MIN 9 20mA INTV G A T A Model Connecting way (DC...
Page 22 - -1 Software Installation
17 5-1 Software Installation : 1. PC Hardware requirements : q HDD 20 MB space, 1.44MB floppy driver, serial ports, 486 PC or above, with COM1, COM2 comports. q EGA or higher display. q 4M bytes or more memory size. 2. Hardware installation : Switch off all power related to your PC. Connect the ...
Page 23 - Setup program will run automatically.
18
A “ Run ” window appears, then type A:\SETUP or B:\SETUP and press “ OK ”. Setup program will run automatically.
Page 24 - Click “NEXT”
19 ê ê Click “NEXT” a). Click “ NEXT ” or b). If willing to set up on a different folder, click “ Browse ”.
Page 25 - Click “ NEXT ”
Page 40 - Escape “SETUP” mode to complete.
35 In the window “SETUP” select the option button named “PRINT MODE” under the title “MODE”. Under the “PRINT” title, select a print mode and then click that button. Escape “SETUP” mode to complete.
Page 43 - -4 Download Datalogger (Graphic Recorder; and then click this button to read recorded data in memory.
38 5-4 Download Datalogger (Graphic Recorder è PC) Move mouse pointer to “Option” then click. Move mouse pointer to “Memory” and then click this button to read recorded data in memory. ò As above, the total memory size is 128K, 126.8K remained.
Page 47 - Move mouse pointer to “File”, then click. And move mouse pointer to “
42 Move mouse pointer to “File”, then click. And move mouse pointer to “ START RECORDING ”, then click this button. The “RECORDING”signal and No.s of PC record will display from 1 up to end.
Page 56 - To show reading values in LIST type, move mouse pointer to “Display”
51
To show reading values in LIST type, move mouse pointer to “Display” then click. And move mouse pointer to “List” and then click this button to launch. ê