Page 2 - OMEGAnet
Servicing North America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTel: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technical or...
Page 3 - Additional features are:
Introduction This manual is a service guide produced by the manufacturer. The manual provides specific procedures and/or illustrations for installa- tion, inspection, cleaning and filtration of all Omega FPR 200 flow sensors. When properly followed, these procedures will keep your flow sensor operat...
Page 4 - Installation - Mechanical; The recommended mounting orientation would be any plane that; See Illustration 1; . The unit will operate satisfactorily with; Mounting Instructions
Installation - Mechanical 1. The flow sensor has NPT (National Pipe Thread) plumbing con- nections. It is recommended that a paste type pipe sealant be used on these threads. [Teflon tape sealant can be used as long as it is applied in such a way that it will not enter the flow stream. Pieces of Tef...
Page 5 - If the LED does not illuminate:
4. It is recommended that the sensor be placed in such a position that the round access cover can be removed for cleaning and tur-bine servicing. It is also recommended that a union be placed near the sensor to allow easy removal. Note1: The flow sensor is a bi-directional measuring device. Referenc...
Page 6 - If data acquisition device does not show an increase in flow rate:
Apply the DC supply voltage directly across the sensor wires. If the LED does illuminate, the load is either: too great of imped- ance or an open circuit. If the LED does not illuminate, the sen- sor's lead wires or circuit are defective. 6. The installation should be complete. Installation - Elec...
Page 7 - If the data acquisition device is not “counting”:
Installation - Electronic (Pulse Output Only) The flow sensor pulse output circuit is a three-wire DC-powered design that transmits a frequency proportional to flow rate. The circuit operates on 5-24 V DC and will consume a maximum of 25 mA from the power supply. 1. Connect the red wire (pin 1 for u...
Page 8 - (Versions with stainless steel sensor body only); Wire Color; Illustration 2
Installation - Electronic (Relay Output Only) 1. Connect the red wire from the sensor to the positive terminal of the 12-35 V DC power supply. 2. Connect the black wire from the transmitter to the negative terminal of the 12-35 V DC power supply. 3. (Versions with stainless steel sensor body only) B...
Page 9 - Service and Maintenance
Set Point Adjustment (Relay Output Only) 1) Adjust the flow rate through the line in which the flow sensor is installed to the rate that corresponds to the desired relay trip point. 2) If the red LED on the back side of the sensor is not illuminated, use a small flat bladed screwdriver to slowly tur...
Page 10 - SPAN
1. Relieve pressure in the piping system. 2. Remove the retainer ring that secures the turbine access cover. 3. Remove the access cover with a pliers, taking care not to damage the o-ring seal. 4. Pull out the turbine assembly and the shaft. 5. Inspect the shaft for things that may have wrapped arou...
Page 11 - Mechanical Specifications; FLOW SENSOR WITH STAINLESS STEEL BODY; Electronic Specifications; ALL VERSIONS WITH 4-20 MA CIRCUIT
Mechanical Specifications FLOW SENSOR WITH STAINLESS STEEL BODY Maximum pressure: 200 PSI clear cover, 500 PSI SS cover Maximum temperature: 225ºF Measuring range*1/2" NPT Ported: 0.5 - 15 GPM 3/4" & 1" NPT Ported: 1.5 - 50 GPM Wetted materials: 316SS, acetal copolymer, Buna, PEEKand...
Page 13 - Dimension Drawings; Dimension with optional clear cover installed; DIM
Dimension Drawings 1 Dimension with optional clear cover installed 2 Polypropylene version only DIM 1/2" NPTF Ports 3/4" & 1" NPTF Ports A 1.94" (49 mm) 3.06" (78 mm) B 1.13" (29 mm) 1.33" (34 mm) C 2.00" (51 mm) 2.46" (62 mm) D 2.45" (62 mm) 2.78" (71...
Page 15 - RETURN REQUESTS/INQUIRIES
WARRANTY/ DISCLAIMER O M E G A E N G I N E E R I N G , I N C . w a r r a n t s t h i s u n i t t o b e f r e e o f d e f e c t s i n m a t e r i a l s a n dworkmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1...