Page 2 - Servicing North America:; ISO 9001 Certifi ed; Canada:; For immediate technical or application assistance:; Czech Republic:; Rudé arm; France:; One Omega Drive, River Bend Technology Centre; OMEGAnet
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certifi cation of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certifi cation. The information contained i...
Page 3 - Omega FMG-3000 Series Magmeter; Quick Start Guide; GROUNDING; Page
1 1 2 3 4 JP2 FREQUENCY OUTDO NOT REMOVE Connect output signals and powerto this 4-terminal block. 2. 4. 3. 3. Sensor Type Pipe Size Jumper Position ½ in. to 2½ in. FMG3001 DN15 to DN65 FMG3002 3 in. to 4 in. DN80 to DN100 FMG3101 5 in. to 6 in. FMG3102 DN125 to DN150 8 in. DN200 FMG3201 10 in. to 1...
Page 4 - psi; Pressure vs. Temperature; Dimensions
2 SAFETY INSTRUCTIONS1. Depressurize and vent system prior to installation or removal.2. Confi rm chemical compatibility before use.3. Do not exceed maximum temperature/pressure specifi cations.4. Wear safety goggles or face shield during installation/service.5. Do not alter product construction.6. Di...
Page 5 - Location; Pipe
3 4. Selecting a Location • The FMG-3000 requires a full pipe and a fully developed turbulent fl ow profi le for accurate measurement. • If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the electrodes. • In vertical installations,...
Page 6 - Use plumber's tape or a suitable sealant on cable ports.; Magmeter
4 Important: • The directional arrow on the body of the sensor must be pointed DOWNSTREAM. • The FLOW arrow decal can be placed directly on the pipe to identify the direction of fl ow. • Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion. • The yellow housing m...
Page 7 - General Installation and Grounding Tips; Sensor conditioning; The maximum loop resistance the Magmeter can accomodate is 300 Ω.
5 6. General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in any container of water) for 24 hours will stabilize the performance.• Very low conductivity fl uids may require...
Page 8 - Frequency; Metal Installation Fittings
6 • The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal. • A 10 K Ω pull up resistor must be connected between terminals 1 and 2 if the magmeter is used with third-party equipment.. 8. Wiring the FMG-3001 and FMG-3101 with Frequency output 1 2 3 4 5-24 VDC Ground Not used F...
Page 9 - Plastic Installation Fittings: PVC Tees and Saddles
7 9. Calibration Data: K-factors* and Full Scale Current Values Plastic Installation Fittings: PVC Tees and Saddles PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM SCH 80 PVC TEES FOR SCH 80 PVC PIPE ½ FP-5305 2289.37 604.85 13.10 49.60 ¾ FP-5307 1430.41 37...
Page 10 - Plastic Installation Fittings for Metric Pipes:
8 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM POLYPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI) ½ FP-5105PO 2192.73 579.32 13.68 51.78 ¾ FP-5107PO 1327.81 350.81 22.59 85.52 1 FP-5110PO 737.16 194.76 40.70 154.04 1¼ FP-5112PO 453.46 119.81 66.16 250.41 1½ FP-5...
Page 11 - Metal Installation Fittings:
9 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM CARBON STEEL TEES ON SCH 40 PIPE ½ FMG-5305CS 1572.66 415.50 19.08 72.20 ¾ FMG-5307CS 1086.73 287.11 27.61 104.49 1 FMG-5310CS 582.34 153.86 51.52 194.99 1¼ FMG-5312CS 377.48 99.73 79.48 300.81 1½ FMG-5315CS...
Page 14 - Ordering Information; OMEGAMAG with Frequency Output; EPDM
12 11. Ordering Information OMEGAMAG with Frequency Output FMG3001-PP OMEGAMAG, Blind, Freq, PP/316SS, ½-4 FMG3101-PP OMEGAMAG, Blind, Freq, PP/316SS, 5-8 FMG3201-PP OMEGAMAG, Blind, Freq, PP/316SS,10-12 FMG-3001-PVDF-HA OMEGAMAG, Blind, Freq, PVDF/Hast, ½-4 FMG3101-PVDF-HA OMEGAMAG, Blind, Freq, PV...
Page 15 - RETURN REQUESTS/INQUIRIES; Model and serial number of the product under; OMEGA is a registered trademark of OMEGA ENGINEERING, INC.; USA
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping...
Page 16 - TEMPERATURE
6-2551.090-OM (C-4/07) M-4210/0407 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE • Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies• Wire: Thermocouple, RTD & Thermistor• Calibrators ...