Summary
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 3 Copyright © 2006 Nortel Networks Contents Finding the latest updates on the Nortel Web site . . . . . . . . . . . . . . . . . . . . 7 How to get help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 5 Copyright © 2006 Nortel Networks Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Adding and configuring the Web Client Manager . . . . . . . . . . . . . . . . . ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Finding the latest updates on the Nortel Web site The content of this documentation was current at the time the product was released. To check for updates to the latest documentation and software...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks How to get help This section explains how to get help for Nortel products and services. Getting help from the Nortel web site The best way to get technical support for Nortel products is from the...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 10 Copyright © 2006 Nortel Networks Getting help from a specialist by using an Express Routing Code To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nort...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Overview The MCS 2-server Sun Fire* V100 Solaris system is a small-scale version of the Multimedia Communication Portfolio (MCP) system, geared towards an environment with a maximum of 250 subscr...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 12 Copyright © 2006 Nortel Networks Figure 2 2-server network with single Ethernet switch Figure 3 2-server network MAS Ad hoc audio conferencing with single Ethernet switch The rest of this document will refer to the example data in the figure tha...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 13 Copyright © 2006 Nortel Networks Figure 4 Example of 2-server Sun Fire V100 Solaris system configuration Restrictions and limitations The 2-server V100 Solaris system is non-redundant. Since redundancy is not built into the s...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 14 Copyright © 2006 Nortel Networks MCS 5100 documentation Refer to the MCS 5100 Network Deployment and Engineering Guide, NN10313-191, that accompanies the MCS 5100 product and to your customer-specific information (CSI) datasheet for your system ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Before you start the installation Prerequisites Have available your completed Customer-Specific Information (CSI) datasheet. Refer to the MCS 5100 Network Deployment and Engineering Guide, NN1031...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 18 Copyright © 2006 Nortel Networks The procedures in this Guide assume that you are using the PuTTY VT100 terminal emulator tool. Provide the following hardware: • Business Policy Switch 2000 (BPS 2000) or Layer-2 switch • One (1) cat-5 Ethernet c...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 19 Copyright © 2006 Nortel Networks Key stroke symbols The following key stroke symbols are used in this document. Text conventions used in this document This document uses the following text conventions: • Bolded type is used t...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 20 Copyright © 2006 Nortel Networks Server configuration The following table shows the basic configuration of the 2-server V100 Solaris system. Loading disks MCS 5100 Release 3.0 Base Platform System SoftWare Kit NTVW01AJ contains multiple copies o...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 21 Copyright © 2006 Nortel Networks MCS Base Platform System Software disks are loaded on the following servers as indicated in Table 2, Mapping of Kit NTVW01BD disks to servers (with times) Table 2 Mapping of Kit NTVW01BD disks...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Minimum and recommended requirements for customer-provided PC Configure your management pc to have an IP address that is in the same subnet of the IP address range used for your servers. Check yo...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Setting up the baseline hardware Baseline hardware See the following figure for an overview of the hardware connectivity. Figure 3 Hardware connections overview ATTENTION You need an uninterrupte...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 27 Copyright © 2006 Nortel Networks • Media Application Server: 1 IBM x336 (2 3.6 GHz Xeon, 1-GB RAM, 1 73-GB SCSI drive, Windows 2000) • Multimedia PC Clients Setting up rack to mount hardware Procedure 1 Setting up rack to mou...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 28 Copyright © 2006 Nortel Networks Figure 4 MCS 5100 19-inch rack Connecting the Sun Fire V100 server to the layer-2 switch Procedure 2 Connecting the V100 server to the layer-2 switch At the back of the Sun Fire V100 server, 1 Connect the Sun Fir...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 29 Copyright © 2006 Nortel Networks Figure 6 Sun Fire V100 server cabling to layer-2 switch Note 1: Net 0 and Net 1 are for redundancy. It is preferable that each Ethernet port get cabled to a different layer-2 switch, if availa...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 30 Copyright © 2006 Nortel Networks Figure 7 Sun Fire V100 server network callouts Note 1: The cables with part numbers A0500465 or NTVW01IM are serial cables. Note 2: The P1 end goes to the V100 server and the P2 end goes to the MRV LX terminal se...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 31 Copyright © 2006 Nortel Networks Figure 8 P1 and P2 custom cable connections to terminal server See note Note : This cable is only connected to configure the terminal server. Following configuration, remove the cable.
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing and accessing the MRV LX-4000 series terminal server The MRV LX terminal server allows the installer to access all the servers simultaneously. Procedure 4 Connecting the MRV LX termina...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 34 Copyright © 2006 Nortel Networks Figure 9 MRV Configuration Console window 2 Make sure you have the Java Plug-in installed. 3 When your browser connects to the terminal server, the Java Security Warning window appears. Figure 10 Java Security Wa...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 36 Copyright © 2006 Nortel Networks Figure 12 Login window 6 Enter your Username and Password, and click Login . Note: By default, authentication is done against the local user database. To start, use the known username InReach and password access ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 37 Copyright © 2006 Nortel Networks Figure 13 User login window 8 To log in as a superuser, click the Admin button on the tool bar and log in with the default Superuser password system. You can now configure the unit at the GUI....
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 38 Copyright © 2006 Nortel Networks Figure 14 Example: selecting Ports: Async a When you click on a port, the following dialog box appears for you to enter your information. Note: In the TCP window (see Figure 15 ), ensure that both the Telnet CR F...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 39 Copyright © 2006 Nortel Networks Figure 15 Port 19 dialog box For details on using the IP Configuration Menu, refer to “Using the IP Configuration Menu” in the LX-Series Configuration Guide. For information on how to boot you...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 40 Copyright © 2006 Nortel Networks Procedure 6 Connecting through the server to the MRV LX terminal server At the management pc, 1 Use the following procedure to access the command line interface port from a dumb terminal attached to an LX Series ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 41 Copyright © 2006 Nortel Networks 4 Enter a new user password at the Enter your NEW password: prompt. The password will be displayed as asterisks. 5 Re-enter the new user password at the Re-Enter your NEW password: prompt. The...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 43 Copyright © 2006 Nortel Networks 4 For port, enter <the port number which corresponds to A/LOM (Serial A) on the V100 and the MRV LX terminal server>. Note 1: For LOM ports, use terminal server ports 2100-2400 (physical...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Powering on the servers Procedure 10 Powering on the servers At the server, 1 Turn power on to the server. 2 If the system boots up, log into the server as root . 3 Type init 0 [ Enter ]. This wi...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing Disks 1 to 3 Installing CD1 Approximate time estimate = 45 minutes Procedure 12 Installing CD1 At the management pc, 1 Place CD1 in the CD-ROM drive. ATTENTION Refer to the customer-sp...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 48 Copyright © 2006 Nortel Networks 2 At the >ok prompt, boot the system: boot cdrom - install [Enter] Note 1: For instructions on how to get to the >ok prompt, see Powering on the servers on page 45 . Note 2: You must wait several minutes be...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 49 Copyright © 2006 Nortel Networks Network Connectivity/Networked 3 Accept the default Yes by pressing Esc+2 to continue. DHCP/Use DHCP 4 Accept the default No by pressing Esc+2 to continue. Primary Network Interface /Primary N...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 50 Copyright © 2006 Nortel Networks Netmask/Netmask 9 Enter the subnet mask, for example: 255.255.255.0 . Press Esc+2 to continue. IPv6/Enables IPv6 10 Accept the default No . Press Esc+2 to continue. There is a slight delay between screens. Please...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 51 Copyright © 2006 Nortel Networks Continuing the process 15 Confirm your information. Ensure all fields are filled correctly. Press Esc+2 to continue. Press Esc+4 if you need to change anything. 16 At the Regions prompt, selec...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 52 Copyright © 2006 Nortel Networks 21 You will see the following message: *********************************************Choose Application configuration:1) AppSvr/IPCM/Websvr/WCM2) Management/Accounting/Oracle/DB************************************...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 53 Copyright © 2006 Nortel Networks Procedure 13 Installing CD2 At the management pc, 1 Place CD2 in the CD-ROM drive and press Enter . You will see a number of messages requiring no specific answer. Press Enter following each o...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 54 Copyright © 2006 Nortel Networks Procedure 14 Installing CD3 At the management pc, 1 Place CD3 in the CD-ROM drive and press Enter at the prompt. The installation will continue. Please wait. The system will prompt you for the next step. 2 Log in...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing Disk 4 Database/Accounting/Management server (DBSvr, AcctMgr, MgmtSvr) Approximate time estimate = 30 minutes Procedure 15 Installing CD4 At the management pc, 1 Place CD4 in the CD-RO...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 56 Copyright © 2006 Nortel Networks to use the local system clock as the time source. Note: Select Time Source • X - External Clock Device • E - External Clock Source {IP Address(es)} • I - Internal Clock (Unreliable) Select option from list above ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 57 Copyright © 2006 Nortel Networks 7 Press Enter to continue. 8 You will see the following statement: ”You are now configuring IPMP (Multipathing)" ”Please have the Database Server Physical IP addresses and the Machine Logi...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 59 Copyright © 2006 Nortel Networks You will see the following message: Obtaining IP Addresses for SysMgr/AcctMgr Failover Operation Note: If you don't have plan to configure the failover service, type in the same primary servic...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 60 Copyright © 2006 Nortel Networks Procedure 16 Installing CD4 At the management pc, 1 Place CD4 in the CD-ROM drive and press Enter to continue. WAIT until you see the following statement appear: ”You are now configuring the NTP time source for t...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 62 Copyright © 2006 Nortel Networks Figure 17 Application server IPMP configuration summary Is this IPMP group configuration acceptable? (Y/N) Select Y to accept or N to change. 14 The default route IP address should appear. If correct, press Enter...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing Disk 5 (all servers) Approximate time estimate is 30 minutes. Procedure 17 Installing CD5 At the management pc, 1 Place CD5 in the CD-ROM drive, on the server, and press Enter at the p...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Enabling or disabling the automatic mount Use the following procedure if you need to use the CD-ROM auto-mount after installation of CD5. Execute this procedure on the MgmtSvr (Server1). Procedur...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing Disk 6 (MgmtSvr/AcctMgr only) Approximate time estimate = 30 minutes Procedure 19 Installing CD 6 At the management pc, 1 Place CD6 in the CD-ROM drive, on the server, and press Enter ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing Oracle 9.2.0.4 on the database server The procedures to install Oracle 9 on the DBSvr include storing Oracle 9 CDs 1-6 to your local hard drive. Refer to the section that follows. Appr...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 70 Copyright © 2006 Nortel Networks 5 cp [ space] Install_CD_to_Disk [ space] / [Enter] 6 cd [ space] / [Enter] 7 ./Install_CD_to_Disk [Enter] 8 Storing data from CDs to the /IMS/ora_cds directory [Y]? : Select Y [Enter] 9 Please insert Oracle Disk...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 71 Copyright © 2006 Nortel Networks Refer to this table when entering the following command: cd [space] /IMS/ora_cds/Disk1 [Enter] ./Oracle_Install PRIMARY <primarydb-hostname> [space] <secondarydb-hostname>[space] |...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 72 Copyright © 2006 Nortel Networks Failing to answer Y will cause the system to raise a disk space alarm on the SysMgr screen for the DBSvr. You will see the message: Removing Disk 1, Disk2, Disk3, Disk4, Disk5, Disk6 from /IMS/ora_cds... . Oracle...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Deploying the initial database load Prerequisites Ensure that the MCS Base Platform Software and Oracle 9i have been installed on database servers. Deploying the MCS database load (imssipdb) Afte...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Deploying and starting the Sysmgr Prerequisites The dbdeploy.pl script is successfully deployed on the database. Deploy the Sysmgr for a non-redundant configuration. The operator logs into the ma...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 76 Copyright © 2006 Nortel Networks 3 Please enter the correct number of the load to deploy: Example [@micromgmt]/export/home/nortel:=> mgmtdeploy.pl Obtaining input required to deploy and configure the mgmtsvr bundle Please enter all IP address...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 77 Copyright © 2006 Nortel Networks Example: 120.120.13.22 7 Will a Motorola SAM16 server (SIP PriGwy or SIP Audio Svr) be deployed? [Y/N] Always answer N [Enter] even if you have a third-party gateway. Note: Information obtaine...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Registering your license key Before installing the license key as described in Procedure 25, Installing the System Management Console , follow the procedure below to generate and register your li...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 80 Copyright © 2006 Nortel Networks Figure 18 KRS login screen 4 In step 1 (Location) select a login server that matches your region, for example, European Login or North American Login. 5 In step 2 (Product Family) select the product you wish to g...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 81 Copyright © 2006 Nortel Networks Figure 19 Keycode Retrieval System, Creating your site 7 Select Create to register a new system. The following screen appears.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 82 Copyright © 2006 Nortel Networks Figure 20 Keycode Retrieval System, Entering your site information 8 Fill in the requested information and press the Continue button. Ensure you choose the correct software version from the dropdown box. Your scr...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 83 Copyright © 2006 Nortel Networks Figure 21 Keycode Retrieval System, Current Summary 9 Select the server you want to enter MAC addresses for first, then click on Create . 10 Enter the MAC addresses of the CORE servers and cli...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 84 Copyright © 2006 Nortel Networks Figure 22 Keycode Retrieval System, Adding MAC address 11 Repeat Step 10 for the second MAC address (required). If you make an error, you can remove one or both and begin again. If you have a second Core that is ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 85 Copyright © 2006 Nortel Networks Server Service Guide applicable to your system (see the Overview chapter for a listing of the service guides). Note: If you have a second Media Application Server for your system, you must sel...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 86 Copyright © 2006 Nortel Networks Figure 24 Keycode Retrieval System, Current Summary 15 To generate keycodes for this site, click on Gen KC with Auth Code from the side bar, as shown in the following figure.
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 87 Copyright © 2006 Nortel Networks Figure 25 Keycode Retrieval System, Gen KC with Auth Code 16 To generate your keycodes, enter one of the MAC addresses of the server you want your Auth code applied to. In this case, the examp...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 88 Copyright © 2006 Nortel Networks Figure 26 Keycode Retrieval System, Finding the keycode 18 Select the proper Software Version for your system. Then click on Continue .
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 89 Copyright © 2006 Nortel Networks Figure 27 Keycode Retrieval System, Adding a MAC address 19 Enter the authcode number for the feature you wish to enable into the Auth Code box. Use the system Authorization codes to build you...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 90 Copyright © 2006 Nortel Networks Figure 28 Keycode Retrieval System, Entering the authcode 20 Select Add to have the KRS accept the authcode. 21 The KRS will validate the authcode and ensure the features represented are valid for your server typ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 91 Copyright © 2006 Nortel Networks Figure 29 Keycode Retrieval System, Summary of features 23 The KRS will indicate it is generating your keycodes and saving the results in its database. After generating the keycodes and saving...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 92 Copyright © 2006 Nortel Networks Figure 30 Keycode Retrieval System, Retrieving the keycode The screens show the features of your keycode and the option to download the keycode to your local PC. To download the keycode click on Download Keycode ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 93 Copyright © 2006 Nortel Networks Figure 31 Keycode Retrieval System, Retrieving your keycode, part 2 24 Download the new license key file to the MgmtSvr hard drive.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 96 Copyright © 2006 Nortel Networks 12 Click Next to begin installation. 13 At the pop-up window that says, Installation successfully completed , click OK . Launching the System Management Console Make sure that the System Management Console applic...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 97 Copyright © 2006 Nortel Networks the License Key->Update dropdown menu (You can also select the System=>License Key=>Update menu option from the System tree.) as shown in Figure 32, Management Console Update License ...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 98 Copyright © 2006 Nortel Networks Figure 33 Select License key File Window 7 Once you have entered the new License Key, you will see a dialog box notifying you whether the update is successful or fails. If the system does not find a license key i...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Adding a server Prerequisites The System Management Console has been successfully installed and started. Adding a server Use this procedure to add each of your servers. Note: You should view the ...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 102 Copyright © 2006 Nortel Networks 5 Click Apply . Longitude Optional field. Describes the longitudinal coordinates of the location of this server. default Platform type Drop-down menu with following choices: Sun or Linux. Select Sun. Sun IP addr...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Adding and configuring the Accounting Module Prerequisites Make sure that • The System Management Console has been successfully installed and started. • A valid license key has been entered and a...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Adding and configuring the SIP Application Module Prerequisites Make sure that • The System Management Console has been successfully installed and started. • A valid license key has been entered ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 115 Copyright © 2006 Nortel Networks 15 Use the table that follows to modify the fields for the Transport Management tab. The shaded rows indicate values that must be addressed by the installer. Modify the public fields only. Th...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 116 Copyright © 2006 Nortel Networks Remote Server Address <machine logical IP of other application server> Only fill PUBLIC Service Address field. 120.120.13.25 Local Server Address Public_Static_Address default Parameters: NSD Number 1 defa...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing the UFTP BaseSoftware You will be installing the UFTP software on the application server. Prerequisites The System Management Console has been successfully installed and started. Note:...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Configuring the Provisioning Module Prerequisites Make sure the System Management Console has been installed and started. Procedures Procedure 35 Adding the Provisioning Module (Small SharedMicro...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 141 Copyright © 2006 Nortel Networks The shaded rows indicate values that must be addressed by the installer. Table 37 IMS Main Database tab (Sheet 1 of 4) Parameter Recommended value Notes Example SNMP request port 9161 default...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 142 Copyright © 2006 Nortel Networks Gauged Component Monitoring: Threshold monitors: Positive going threshold value 1 70 default Gauged Component Monitoring: Threshold monitors: Positive going threshold hysteresis 1 5 default Gauged Component Moni...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 143 Copyright © 2006 Nortel Networks Gauged Component Monitoring: Threshold monitors: Alarm Severity on Positive Going Threshold2 MINOR default Gauged Component Monitoring: Threshold monitors: Alarm Severity on Maximum Rate MAJO...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Installing the iPlanet Monitor Prerequisites Make sure the System Management Console has been successfully installed and started. Procedures Procedure 41 Adding the iPlanet Monitor At the System ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 149 Copyright © 2006 Nortel Networks Component Monitoring: Threshold monitors: Lower Limit 0 default Component Monitoring: Threshold monitors: Negative going threshold value 10 default Component Monitoring: Threshold monitors: N...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 157 Copyright © 2006 Nortel Networks Component Monitoring: Threshold monitors: Positive going threshold hysteresis 1 5 default Component Monitoring: Threshold monitors: Positive going threshold value 2 85 default Component Monit...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 158 Copyright © 2006 Nortel Networks Component Monitoring: Threshold monitors: Alarm Severity on Upper Limit OverRun MAJOR default Component Monitoring: Threshold monitors: Alarm Severity on Lower Limit UnderRun MAJOR default Component Monitoring: ...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Verification procedures Verifying Server1 (DBSvr/MgmtSvr/AcctMgr) The following commands are executed on the database/management/accounting Sun Fire V100 server using PuTTY SSH into the machine l...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 162 Copyright © 2006 Nortel Networks interface is ‘UP.’ This example output shows that dmfe0 is assigned to IP address 120.120.13.20, its subnet mask is ffffff00, which translates to 255.255.255.0, and the interface is UP (active). 4 Look for the e...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 163 Copyright © 2006 Nortel Networks 120.120.13.1 The only address in this file defines your default gateway route (your router). If this file is empty and the machine is rebooted, then you will not have network access to your o...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 164 Copyright © 2006 Nortel Networks 4 Look for the entry that starts with ‘dmfe1.’ The parameters that follow show the IP address, subnet mask, and whether the interface is ‘UP.’ This example output shows that dmfe1 is assigned to IP address 120.1...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 165 Copyright © 2006 Nortel Networks The only address in this file defines your default gateway route (your router). If this file is empty and the machine is rebooted, then you will not have network access to your other servers....
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Appendix A Deploying the PC Client Along with the initial load, Nortel Networks delivers the following: • Java Network Launch Protocol (JNLP) file: pcclient.jnlp • Zip file containing latest code...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks Appendix B Reloading IP addresses after system installation This process prompts you for the hostname, country, time-zone, and IP address to enable movement of the system after the system is inst...
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 170 Copyright © 2006 Nortel Networks the server, which takes about five minutes, and then reload the IP addresses (see Procedure 46, Reloading IP addresses after system installation ). Reloading the IP addresses on each server takes about 15 minute...
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide 171 Copyright © 2006 Nortel Networks Type the number of your choice and press Return: Select 2 and press Enter . 7 See the instructions for installing Disk 1 in this document for more information on what to enter for the followi...
Multimedia Communication Portfolio Multimedia Communication Server 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks. All rights reserved. The information in this document is subject to change without notice. The statements, configurations, technica...
Nortel Manuals
-
Nortel ELO ES24
Manual
- Nortel S5100 Manual
-
Nortel BSG12aw
Manual
-
Nortel 2332
Manual
-
Nortel M 901
Manual
- Nortel M3310 Manual
-
Nortel NN43001-307
Manual
-
Nortel 60-12T
Manual
-
Nortel 5580
Manual
-
Nortel NN43113-106
Manual
-
Nortel 3456
Manual
-
Nortel 1100 Series
Manual
-
Nortel 10396EA
Manual
-
Nortel 3395A
Manual
-
Nortel IP 560
Manual
-
Nortel BSR252
Manual
-
Nortel 5399
Manual
- Nortel S1100PJ Manual
-
Nortel P0941753 02
Manual
-
Nortel 8000
Manual