Page 2 - Use of controls or adjustments, or performance
Copyright © 2002 Nortel Networks All rights reserved. January 2002 . The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express ...
Page 3 - Only qualified technicians should install this
1 Product Safety Meets requirements of: CSA 22.2 No. 950-M95/UL1950, 3rd ed.EN60950: 1992 /A1:1993 /A2:1993 /A3:1995 /A4:199721CFR, Chapter IEN60825-1:1994 /A11:1996 Caution: Only qualified technicians should install this equipment. Place all printed circuit boards on an antistatic mat until you are...
Page 4 - Introduction to Gigabit Interface Converters; Product description; products to allow Gigabit Ethernet ports to
2 Introduction to Gigabit Interface Converters This section describes the Gigabit Interface Converter (GBIC) and label, and provides a GBIC model list. Product description Gigabit Interface Converters (GBICs) are hot-swappableinput/output enhancement components designed for use with Nortel Networks*...
Page 5 - Figure 1; GBIC extraction tabs and extractor handle; GBIC labeling; The Nortel Networks label on a typical GBIC; Figure 2; Nortel Networks GBIC label
3 Figure 1 GBIC extraction tabs and extractor handle GBIC labeling The Nortel Networks label on a typical GBIC (Figure 2) contains a Nortel Networks serial number, a bar code, a manufacturer’s code, an interface type, and a part number. Figure 2 Nortel Networks GBIC label 9702FA GBIC model with extr...
Page 6 - GBIC and SFP GBIC model list; Table 1; Nortel Networks GBIC and SFP GBIC models
4 GBIC and SFP GBIC model list Table 1 lists and describes the Nortel Networks GBIC and SFP GBIC models. Note: When you contact a Nortel Networks service representative for troubleshooting purposes, you must have the following information available: • Nortel Networks serial number • Manufacturer’s c...
Page 7 - Installing a GBIC; This section lists the steps to install a GBIC.
5 Handling, safety, and environmental guidelines Before installing your GBIC, read the following handling, safety, and environmental guidelines: • GBICs are static sensitive. To prevent damage from electrostatic discharge (ESD), follow your normal board and component handling procedures. • GBICs are...
Page 8 - Figure 3; Inserting the GBIC into the switching module; Removing a GBIC; This section lists the steps for removing a GBIC.
6 2 Verify that the GBIC is the correct model for your network configuration ( Table 1 on page 4 ). 3 Remove the dust cover from the GBIC’s optical bores. 4 Grasp the GBIC between your thumb and forefinger. 5 Insert the GBIC into the slot on the front panel of the Gigabit Ethernet switching module (...
Page 9 - Table 2; GBIC specifications
7 2 Depending on your GBIC model, either grasp the extraction tabs ( Figure 1 ) located on either side of the GBIC with your thumb and forefinger, or lift the extractor handle ( Figure 1 ) attached to the GBIC. 3 Slide the GBIC out of the Gigabit Ethernet module slot. 4 If the GBIC does not slide ea...
Page 10 - Table 3; 000BASE-SX specifications
8 Standards, connectors, cabling, and distance This section describes GBIC standards, connectors, cabling, and distance; and provides specifications for the following GBICs: • “1000BASE-SX,” next • “1000BASE-LX” on page 9 • “1000BASE-XD” on page 11 • “1000BASE-ZX” on page 13 • “1000BASE-T” on page 1...
Page 11 - Type
9 1000BASE-LX The Model 1000BASE-LX GBIC provides 1000BASE-LX (1300 nm, wavelength, Gigabit Ethernet) connectivity using SC duplex fiber connectors. The long wavelength optical transceivers used in the LX model provide variable distance ranges using both multimode and single-mode fiber optic cabling...
Page 12 - Table 4; 000BASE-LX specifications
10 Table 4 describes standards, connectors, cabling, and distance for the Model 1000BASE-LX GBIC. Table 4 1000BASE-LX specifications Type Specifications Standards Conformity to the following standards: 802.3z, 1000BASE-LX Connectors Duplex LC fiber optic connector Cabling 62.5 µm MMF optic cable 50 ...
Page 13 - Table 5; 000BASE-XD GBIC specifications
11 1000BASE-XD The Model 1000BASE-XD GBIC provides Gigabit Ethernet connectivity using SC duplex single-mode fiber connectors. High-performance optical transceivers enable Gigabit Ethernet link distances up to 50 kilometers (km) over single-mode fiber. The ports operate in full-duplex mode only. Tab...
Page 14 - Nortel Networks recommends that you use an
12 Connectors Duplex SC single-mode fiber optic connector Cabling Single-mode fiber optic cable Distance Up to 50 km using single-mode fiber cable, depending on the quality of the fiber Optical budget 17 dB Laser Transmitter Characteristics Wavelength 1550 ± 10 nm Maximum spectral width 0.2 nm Maxim...
Page 15 - Table 6; 000BASE-ZX GBIC specifications
13 1000BASE-ZX The Model 1000BASE-ZX GBIC provides Gigabit Ethernet connectivity using SC duplex single-mode fiber connectors. High-performance optical transceivers enable Gigabit Ethernet link distances up to 70 km over single-mode fiber cable. The ports operate in full-duplex mode only. Table 6 de...
Page 16 - When shorter lengths of single-mode fiber cable
14 Distance 70 km Receiver Characteristics Wavelength 1200 to 1550 nm Minimum receiver sensitivity -22 dBm Maximum input power -3 dBm Note: When shorter lengths of single-mode fiber cable are used, there is a risk of overloading the receiver. It may be necessary to insert an in-line optical attenuat...
Page 17 - Table 7
15 1000BASE-T The Model 1000BASE-T GBIC provides 1000BASE-T (Gigabit Ethernet) connectivity. Table 4 describes standards, connectors, cabling, and distance for the Model 1000BASE-LX GBIC. Table 7 1000BASE-LX specifications Type Specifications Standards Conformity to the following standards: IEEE 802...
Page 18 - products to; Figure 4; SFP GBIC
16 Introduction to Small Form Factor Pluggable (SFP) Gigabit Interface Converters This section describes the Small Form Factor Pluggable (SFP) Gigabit Interface Converter (GBIC) and label, and provides a SFP GBIC model list. Product description Small Form Factor Pluggable Gigabit Interface Converter...
Page 19 - SFP GBIC labeling; Figure 5; Nortel Networks SFP GBIC label; Top view
17 SFP GBIC labeling The Nortel Networks label on a typical SFP GBIC (Figure 5) contains a Nortel Networks serial number, a bar code, a manufacturer’s code, an interface type, and a part number. Figure 5 Nortel Networks SFP GBIC label Note: When you contact a Nortel Networks service representative f...
Page 20 - SFP GBIC model list; Table 8; Nortel Networks SFP GBIC models; The cable distance may vary depending on the
18 SFP GBIC model list Table 8 lists and describes the Nortel Networks SFP GBIC models. Handling, safety, and environmental guidelines Before installing your SFP GBIC, read the following handling, safety, and environmental guidelines: • SFP GBICs are static sensitive. To prevent damage from electros...
Page 22 - Figure 6; Inserting a LC SFP GBIC; Figure 7; Inserting a MT-RJ SFP GBIC; SFP GBICs are keyed to prevent incorrect
20 Figure 6 Inserting a LC SFP GBIC Figure 7 Inserting a MT-RJ SFP GBIC Note: SFP GBICs are keyed to prevent incorrect insertion. Link Act BPS2000-2GE MDA Link Act BPS2000-2GE MDA CWGBIC.fm Page 20 Wednesday, December 12, 2001 11:26 AM
Page 23 - Figure 8; Slide the SFP GBIC out of the Gigabit Ethernet module slot.; LC SFP GBIC
21 Removing a Small Form Factor Pluggable (SFP) GBIC This section lists the steps for removing a GBIC. To remove a GBIC: 1 Disconnect the network fiber cable from the SFP GBIC connector. 2 Depending on your SFP GBIC model, either pull the LC extraction tab located in the front of the SFP GBIC (below...
Page 24 - Table 9; specifications
22 5 Dispose of the SFP GBIC according to all national laws and regulations. Small Form Factor Pluggable (SFP) GBIC specifications Table 9 describes general SFP GBIC specifications. Standards, connectors, cabling, and distance This section describes SFP GBIC standards, connectors, cabling, and dista...
Page 30 - Nortel Networks CWDM SFP GBIC List
28 CWDM SFP GBIC Listing Table 13 lists the Nortel Networks CWDM SFP GBICs and describes their wavelengths, color codes, part numbers, and cable lengths. Table 13 Nortel Networks CWDM SFP GBIC List CWDM SFP GBIC Product number Cable Length 1470nm/Gray AA1419025 AA1419033 40 KM 70 KM 1490nm/Violet AA...
Page 31 - CWDM SFP GBICs are installed and removed; CWDM SFP GBIC specifications
29 CWDM SFP GBIC specifications Note: CWDM SFP GBICs are installed and removed like any other LC type SFP GBIC. Table 14 CWDM SFP GBIC specifications Item Specification Physical dimensions 0.457 X .604 X 2.18 inches(11.6 X 15.3 X 55.43 mm) Connectors Duplex LC fiber optic Cabling SMF, 9 µm Data rate...
Page 33 - documentation; How to get help
31 Connecting to Nortel Networks online This section describes products, services, and support systems that can be accessed online. Hard-copy technical manuals You can print selected technical manuals and release notes free, directly from the Internet. Go to the www.nortelnetworks.com/ documentation...
Page 34 - Technical Solutions Center
32 If you purchased a Nortel Networks service program, contact one of the following Nortel Networks Technical Solutions Centers: An Express Routing Code (ERC) is available for many Nortel Networks products and services. When you use an ERC, your call is routed to a technical support person who speci...