Page 2 - North American Regulatory Information; Safety; Read and follow installation instructions carefully.
2 P0607274 02 Copyright © 2004 Nortel Networks All rights reserved. 2004. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without exp...
Page 3 - Radio-frequency Interference; Equipment generates RF energy.
3 UPS Installation and Configuration Guide Radio-frequency Interference Telecommunication Registration Business Communications Manager equipment meets all applicable requirements of both Industry Canada CS-03 and US Federal Communications Commission (FCC) Part 68 and has been registered under files ...
Page 4 - Telephone Company Registration; telephone number(s) to which the system will be connected; Rights of the Telecommunications Company; Notice
4 P0607274 02 Telephone Company Registration It is usually not necessary to call the telecommunications company with information on the equipment before connecting the Business Communications Manager system to the telephone network. If the telecommunications company requires this information, provid...
Page 5 - Nortel Networks; US Regulations - please read carefully; Federal Communications Commission (FCC) Notice
5 UPS Installation and Configuration Guide Notice The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices...
Page 6 - Important Safety Instructions; Installation; Never install the UPS or other equipment during a lightning storm.
6 P0607274 02 • If a network interface jack is not already installed in your location, you can order one from your telephone company. Order the appropriate USOC Network interface jack, as specified in the installation instructions, for wall-mounted telephones or for desk/table use. In some states, c...
Page 7 - Use
7 UPS Installation and Configuration Guide Use When using your UPS equipment, basic safety precautions should always be followed to reduce risk of fire, electric shock and injury to persons, including the following: 1 Read and understand all instructions. 2 Follow the instructions marked on the prod...
Page 8 - Only qualified persons should service the system.
8 P0607274 02 Safety WARNING! Only qualified service personnel may install this equipment. The instructions in this manual are intended for use by qualified service personnel only. Risk of shock. Ensure the Business Communications Manager is unplugged from the power socket before installing the UPS ...
Page 11 - Preface; Display Tips
11 UPS Installation and Configuration Guide Preface This guide describes how to install, initialize and monitor the Business Communications Manager Uninterruptable Power Supply (UPS) device. Information in these chapters explains: • how to set up the UPS • how to start and initialize the UPS • how t...
Page 12 - Figure 1 Acrobat Reader display setup selections; Symbols used in this guide; Tip Symbol
12 Preface P0607274 02 Figure 1 Acrobat Reader display setup selections Symbols used in this guide This guide uses the following symbols to draw your attention to important information: Caution: Caution Symbol Alerts you to conditions where you can damage the equipment. Danger: Electrical Shock Haza...
Page 13 - Text conventions; This guide uses the following text conventions:; Related publications; Disconnect Symbol; bold Courier text; italic text; bold text
Preface 13 UPS Installation and Configuration Guide Text conventions This guide uses the following text conventions: Related publications The following documents provide further information about the Business Communications Manager, related media bay modules, extension equipment, and system applicat...
Page 15 - BCM and UPS power and control connections; UPS Overview
15 UPS Installation and Configuration Guide Chapter 1Uninterruptable Power Supply (UPS) Overview This book describes how to install, configure and monitor the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models. This chapter provides an overview ...
Page 16 - 6 Chapter 1 Uninterruptable Power Supply (UPS) Overview; Figure 2 UPS/BCM power connections and topology
16 Chapter 1 Uninterruptable Power Supply (UPS) Overview P0607274 02 The UPS device is supported in all markets (110~120V and 220~240V power standards). All BCMs using version 3.5 software or higher can use the UPS device. BCM and UPS power and control connections The UPS device operates in parallel...
Page 17 - Chapter 1 Uninterruptable Power Supply (UPS) Overview 17; UPS threshold values; The threshold values relate to the following:
Chapter 1 Uninterruptable Power Supply (UPS) Overview 17 UPS Installation and Configuration Guide UPS threshold values UPS threshold values are tolerances that define the UPS operational requirements and power delivery capability. The UPS reports the threshold values through the Unified Manager. The...
Page 19 - Chapter 1 Uninterruptable Power Supply (UPS) Overview 19; Table 1 UPS Event messages
Chapter 1 Uninterruptable Power Supply (UPS) Overview 19 UPS Installation and Configuration Guide 203200 Main intelligence module removed Warn 200400 UPS runtime calibration cancelled Info 203300 Main intelligence module failed Error 200401 UPS runtime calibration cancelled by user Info 1030 Minimum...
Page 20 - 0 Chapter 1 Uninterruptable Power Supply (UPS) Overview; Operational measurements and accounting; Log files and traces; are captured in the log file which can; UPS default configuration settings; Table 2 UPS default settings
20 Chapter 1 Uninterruptable Power Supply (UPS) Overview P0607274 02 Operational measurements and accounting The Business Communications Manager collects operational measurement (OM) information from the UPS and saves the data in a log file. The OM information is viewed through the Unified Manager o...
Page 21 - Chapter 1 Uninterruptable Power Supply (UPS) Overview 21; Shutdown
Chapter 1 Uninterruptable Power Supply (UPS) Overview 21 UPS Installation and Configuration Guide Error Log Enabled Yes Error Log Location “F:\Program Files\PwerChute\PwrChute.err” Select the Error Log Maximum 5000 KB. Shutdown Shutdown Delay 30 Seconds Admin Shutdown Delay 30 Seconds Table 2 UPS de...
Page 22 - 2 Chapter 1 Uninterruptable Power Supply (UPS) Overview
22 Chapter 1 Uninterruptable Power Supply (UPS) Overview P0607274 02
Page 23 - Install and Initialize the UPS; Initialize the serial port
23 UPS Installation and Configuration Guide Chapter 2Install and Initialize the Uninterruptable Power Supply This chapter describes how to install and initialize the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models. This chapter describes the ...
Page 24 - Figure 3 UPS Configuration screen; This procedure is complete.; UPSConsoleToggle Service
24 Chapter 2 Install and Initialize the Uninterruptable Power Supply P0607274 02 5 Select the UPS Configuration tab from the UPS setup screen. The UPS Configuration screen appears (see Figure 3 on page 24 ). Figure 3 UPS Configuration screen 6 Select the UPS radio button to enable the serial port fo...
Page 25 - Enable UPSConsoleToggle; Use this procedure to enable the UPSConsoleToggle service.
Chapter 2 Install and Initialize the Uninterruptable Power Supply 25 UPS Installation and Configuration Guide After 15 minutes, the service switches back to the UPS to enable the UPS (if the UPS was originally selected and enabled). • To extend the Console time, stop the UPSConsoleToggle using the c...
Page 27 - This section describes the following procedures:; Monitor the UPS; Provides a warning signal when UPS battery power is low.
27 UPS Installation and Configuration Guide Chapter 3Monitor the Uninterruptable Power Supply This section describes how to monitor the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models. This section describes the following procedures: Access t...
Page 28 - 8 Chapter 3 Monitor the Uninterruptable Power Supply; Access the UPS Status monitor; Initialize the serial port as described in; Select the UPS heading from the navigation tree window.; Figure 4 UPS Status Monitor screen
28 Chapter 3 Monitor the Uninterruptable Power Supply P0607274 02 Access the UPS Status monitor Use this procedure to access the UPS status monitor tab interface and monitor the UPS device. 1 Initialize the serial port as described in Initialize the serial port on page 23. 2 Access the correct Busin...
Page 29 - Chapter 3 Monitor the Uninterruptable Power Supply 29; Access the UPS OM and log reports; Select the Report from the top line menu.; Figure 5 UPS OMs report; Figure 6
Chapter 3 Monitor the Uninterruptable Power Supply 29 UPS Installation and Configuration Guide Access the UPS OM and log reports Use this procedure to access the UPS operational metrics (OMs), UPS log files, or status reports. 1 Initialize the serial port as described in Initialize the serial port o...
Page 30 - To print the report, select Print this Report from the screen.; Access the UPS status report; Select the Report from the top-line menu.
30 Chapter 3 Monitor the Uninterruptable Power Supply P0607274 02 Figure 6 UPS Log file report 9 To print the report, select Print this Report from the screen. 10 To close the report window, select Close This Window from the screen. 11 This procedure is complete. Access the UPS status report Use thi...
Page 31 - Chapter 3 Monitor the Uninterruptable Power Supply 31; Figure 7 UPS status report; Test the UPS
Chapter 3 Monitor the Uninterruptable Power Supply 31 UPS Installation and Configuration Guide Figure 7 UPS status report 7 To print the report, select Print this Report from the screen. 8 To close the report window, select Close This Window from the screen. 9 This procedure is complete. Test the UP...
Page 32 - 2 Chapter 3 Monitor the Uninterruptable Power Supply; After system shutdown, restore power to the UPS device.
32 Chapter 3 Monitor the Uninterruptable Power Supply P0607274 02 4 Verify that a warning message and/or alert appears on the client screen. 5 Wait until the UPS battery reaches a low level. A system shutdown should occur (on the BCM 200, 400, and 1000). 6 After system shutdown, restore power to the...