3 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique (8000 Series chassis) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A...
4 312755-G Rev 00 Denan statement (Japan/Nippon only) National safety statements of compliance CE marking statement (Europe only) EN 60 950 statement This is to certify that the Nortel 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 95...
5 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis reverse engineer or otherwise translate the Software; c) create derivative works or modifications unless expressly authorized; or d) sublicense, rent or lease the Software. Licensors of intellectual property to N...
7 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
11 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Figures Figure 1 Breaker interface panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 2 Front panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
13 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Tables Table 1 Alarm module display LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 2 DC power requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
15 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Preface The breaker interface panel (BIP) provides power distribution and alarm status indications for one or two 8010co chassis in an equipment rack. The status indications can be linked to other BIPs to provid...
16 Preface 312755-G Rev 00 Text conventions This guide uses the following text conventions: How to get Help This section explains how to get help for Nortel products and services. Getting Help from the Nortel Web site The best way to get technical support for Nortel products is from the Nortel Techn...
Preface 17 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis • sign up for automatic notification of new software and documentation for Nortel equipment • open and manage technical support cases Getting Help over the phone from a Nortel Solutions Center If you don...
19 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Chapter 1Overview This chapter provides an overview of the BIP and covers the following topics: • Physical description • “Accessing the alarm module” on page 30 • “Configuration example” on page 32 Physical desc...
20 Chapter 1 Overview 312755-G Rev 00 Front panel Figure 2 shows the BIP front panel components. Figure 2 Front panel components Shelf circuit breakers (upper and lower shelves) Two groups of three circuit breakers provide input power to the power supplies for the upper and lower shelf 8010co chassi...
Chapter 1 Overview 21 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Figure 3 Shelf circuit breakers 10372EA 1 1 = Upper shelf LEDs2 = Lower shelf LEDs Front of rack Upper Shelf 1 2 3 1 2 3 Lower Shelf 2 Upper shelf power supplies PS 1 + DC– DC PS 2 + DC– DC PS...
22 Chapter 1 Overview 312755-G Rev 00 Alarm module display panel The alarm module display panel ( Figure 4 ), located on the BIP front panel, provides visual status indications for one or two 8010co chassis in a single rack. Figure 4 Alarm module display panel See Table 1 for a description of the LE...
Chapter 1 Overview 23 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis The alarm module can also be linked to other BIPs, and can provide visual and audible alarms to aisle alarms and to the central office (see “Central office alarms” on page 26 ). Alarm support ...
24 Chapter 1 Overview 312755-G Rev 00 Front panel locking screws The front panel locking screws allow you to open the front panel to access the alarm module. The alarm module contains jumpers that you use to configure your system alarm parameters. For information about configuring your system alarm ...
Chapter 1 Overview 25 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Figure 6 shows the location of the shelf alarm connectors on the BIP and on two 8010co chassis (upper and lower shelves). Figure 6 Shelf alarm connections (upper and lower shelves) 1 = J1 (BIP...
26 Chapter 1 Overview 312755-G Rev 00 Central office alarms The central office alarm connectors allow you to aggregate alarms from multiple BIPs and route them to an aisle alarm and to the central office. Figure 7 shows three BIPs configured to aggregate alarms from three racks. You can configure up...
Chapter 1 Overview 27 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis This type of configuration allows you to independently monitor and control the external audible and visual alarm status indications of the BIP at the central office. Figure 8 Configuring stand...
28 Chapter 1 Overview 312755-G Rev 00 Figure 9 Power terminal block Figure 10 on page 29 shows an example of the BIP power terminal block cabling including ground connections for two 8010co chassis and installed power supplies. As shown in this example, both upper and lower chassis are each fully co...
30 Chapter 1 Overview 312755-G Rev 00 Accessing the alarm module The alarm module contains jumpers that you can configure to allow the BIP to monitor the shelf alarm cables for a single or dual chassis installation. The BIP ships from the factory with default jumper configurations set for a single c...
Chapter 1 Overview 31 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 2 Gently lower the front panel to expose the alarm module ( Figure 12 ). Figure 12 Accessing the alarm module Figure 13 shows a close-up view of the alarm module with jumpers J8 and J9 configu...
32 Chapter 1 Overview 312755-G Rev 00 Configuration example Figure 14 shows a typical configuration using the optional breaker interface panel. Figure 14 8010co chassis configuration with BIP option 10420EB 1 = Breaker interface panel2 = 8010co Chassis (upper shelf position)3 = 8010co Chassis (lower...
33 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Chapter 2Installation This chapter describes how to install the breaker interface panel and covers the following topics: • “Preparing to install the breaker interface panel ” next • “Installing the breaker inter...
34 Chapter 2 Installation 312755-G Rev 00 Shipment contents Inspect all items for shipping damage. If you detect any damage, do not install the BIP. Call the Nortel Technical Solutions Center in your area (see “How to get Help” on page 16 ). Your BIP shipment contains the following items ( Figure 15...
Chapter 2 Installation 35 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Additional equipment To install the BIP, you might need items that are not part of the BIP installation kit. Before installing the BIP hardware, ensure that you obtain all the cables, tool...
36 Chapter 2 Installation 312755-G Rev 00 Installing the breaker interface panel This section covers the following topics: • “Installing the hardware ” next • “Connecting cables to the chassis power supplies” on page 38 • “Routing power supply cables to the BIP” on page 47 • “Connecting the ground c...
Chapter 2 Installation 37 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis To install the BIP: 1 Remove the plastic back cover from the BIP terminal block ( Figure 16 ). Figure 16 Removing the plastic back cover from the BIP 2 Position the BIP in the uppermost po...
38 Chapter 2 Installation 312755-G Rev 00 Connecting cables to the chassis power supplies This section describes how to connect the BIP power cables to the 8010co chassis 8004DC power supplies. These procedures assume that all required power supplies were previously installed during the 8010co chass...
Chapter 2 Installation 39 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis To connect cables to the chassis power supplies: 1 Remove the 8010co chassis bottom bezels (if required). a Using a Phillips screwdriver, loosen the 2 captive screws securing the bezel to ...
40 Chapter 2 Installation 312755-G Rev 00 2 Locate the power supplies ( Figure 19 ). With the bezel removed, you can see the power supplies. The chassis can contain up to three power supplies. (Power supplies reside in bay 1, bay 2, and bay 3, viewed left to right from the front of the chassis.) Fig...
42 Chapter 2 Installation 312755-G Rev 00 5 Remove the Phillips screw securing the plastic safety cover to the power supply, and then remove the cover ( Figure 22 ). Save the Phillips screw and the cover for replacement later. Figure 22 Removing the plastic safety cover from the power supply 6 Note ...
Chapter 2 Installation 43 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 7 Locate the following items in the shipping container ( Figure 24 ). • 125-inch power cables—for power supplies located in the lower chassis • 90-inch power cables—for power supplies loca...
Chapter 2 Installation 45 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 10 Attach the lug end of a 125-inch power supply cable to the negative terminal on the power supply ( Figure 27 ). Use a 7/16-inch hex wrench to fasten the hardware in the correct order. F...
46 Chapter 2 Installation 312755-G Rev 00 12 Secure the power supply in bay 1 of the lower chassis ( Figure 29 ). a Use the power supply handle to push the power supply firmly into bay 1. b Push the extractor lever down to lock the power supply in place. c Tighten the two power supply retaining scre...
Chapter 2 Installation 47 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Routing power supply cables to the BIP After you connect all cables to the chassis power supplies, you must route the power supply cable leads from each chassis to the BIP. If you installe...
48 Chapter 2 Installation 312755-G Rev 00 5 Route the remaining (black) power supply cables from the back of the lower and upper shelf chassis to the back panel of the BIP, loosely fastening them with tie-wraps along the path. 6 Loosely support the power supply cables with tie-wraps above the BIP po...
Chapter 2 Installation 49 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Connecting the power supply cables to the BIP To connect the power supply cables to the BIP: 1 Locate one of the power supply cables. 2 Match the labeled tag on the power supply cable with...
50 Chapter 2 Installation 312755-G Rev 00 4 Repeat steps 1 through 3 for each remaining power supply in your configuration ( Figure 33 ). Figure 33 Upper and lower shelf power cables connected to the BIP 5 Locate the BIP ground cable (see Figure 30 on page 47 ). 10394FA 3 2 PS (+) Lower Shelf PS (+)...
Chapter 2 Installation 51 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 6 Attach one end of the BIP ground cable to the power terminal block ( Figure 34 ). a Loosen the power terminal block screw just enough to insert the ground cable lead (item 1 in Figure 34...
52 Chapter 2 Installation 312755-G Rev 00 Connecting DC input power feeds to the BIP Nortel does not supply the cables for connecting the breaker interface panel to the DC input power source. You must select cables that comply with the electrical code of the country where you intend to use the DC-DC...
Chapter 2 Installation 53 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Figure 35 A and B feed example Table 3 lists input power options for single and dual chassis installations. Table 3 Single chassis and dual chassis input options Single chassis input * * F...
54 Chapter 2 Installation 312755-G Rev 00 To connect the DC input feeds to the BIP: 1 Locate the DC power source for the DC input feed. 2 Determine the power requirements for your configuration (see Figure 35 on page 53 ). 3 Locate the A and B -48 VDC input feeds ( Figure 36 ). The -48 VDC input fee...
Chapter 2 Installation 55 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 4 Connect the -48 VDC input feeds according to your configuration requirements. a Match the tagged -48 VDC input feed cable lead with the correct power terminal block on the back of the BI...
56 Chapter 2 Installation 312755-G Rev 00 5 Connect the remaining -48 VDC input feeds and returns as required ( Figure 38 ). Figure 38 Connecting the A and B -48 VDC input feeds to the BIP (2 of 2) Note: Figure 38 shows the attachment of two “A” feeds and two “B” feeds to the BIP. Note that there is...
58 Chapter 2 Installation 312755-G Rev 00 7 Connect the remaining -48 VDC input returns as required ( Figure 40 ). Figure 40 shows the BIP with all power cables and returns installed. Figure 40 Connecting the A/B input feed returns (2 of 2) 8 Go to the next section, “Replacing covers” on page 59 . N...
Chapter 2 Installation 59 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Replacing covers After you complete all of the cabling requirements as described in the previous sections, you must replace the plastic back cover on the BIP and the 8010co chassis bezel(s...
60 Chapter 2 Installation 312755-G Rev 00 2 Replace the 8010co chassis bezel. a Set the notch (on both ends of the 312096-A bezel) into the tabs on the chassis ( Figure 42 ). b Lift the top of the bezel up, and then align the captive screws with the holes in the chassis. c Using a Phillips screwdriv...
Chapter 2 Installation 61 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Installing shelf alarm cables 1 To install the shelf alarm cable for a single chassis in the lower shelf: a Locate the shelf alarm cables in the shipping container. b Connect one end of th...
62 Chapter 2 Installation 312755-G Rev 00 2 To install the shelf alarm cable for a second chassis in the upper shelf: a Configure the jumpers on the alarm module to support a second chassis in the upper shelf as described in “Accessing the alarm module” on page 30 . b Connect one end of the shelf al...
Chapter 2 Installation 63 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Initial power-up To power up the 8010co chassis: 1 Set the six circuit breakers on the BIP front panel to the off position (O = Off). 2 Set the switches for all power supplies in the upper...
64 Chapter 2 Installation 312755-G Rev 00 4 Verify the following LEDs on the 8010co chassis: — The (green) power supply LEDs for each power supply in both the upper and lower chassis are on. (If any of the power supply LEDs are not on, replace the power supply.) — The chassis fans are powering up. I...
Chapter 2 Installation 65 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 4 Continue with the installation of the 8010co chassis as described in the appropriate product chassis installation manual. Note: When you power off the 8010co chassis, wait at least 30 se...
68 Chapter 3 Problem solving 312755-G Rev 00 Interpreting the LEDs All BIP LEDs and indicators are located on the front panel ( Figure 44 ). Figure 44 BIP LEDs and indicators Table 4 describes the BIP LEDs and indicators. Table 4 BIP LEDs and indicators Item Label/Icon Type Color/State Description 1...
Chapter 3 Problem solving 69 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis If you need more help, go to the next section, “Diagnosing and correcting the problem” on page 70 . 4 POWER Indicator White/On steady Power indicator—The external DC power is available ...
70 Chapter 3 Problem solving 312755-G Rev 00 Diagnosing and correcting the problem Before you perform the problem-solving steps in this section, complete the following steps: 1 Set the switches for all power supplies in the upper and lower chassis to the off position (O = Off). 2 Set the six circuit...
Chapter 3 Problem solving 71 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Corrective actions To resolve problems with the BIP or the 8010co chassis and components, follow the corrective actions suggested in Table 5 . Table 5 Corrective actions Symptom Probabl...
72 Chapter 3 Problem solving 312755-G Rev 00 The (red) CRITICAL indicator is on steady. Failover from Master CPU to the second (redundant) CPU. This action is preceded by the CRITICAL indicator blinking two times and then turning off after the redundant CPU becomes operational. After the Redundant C...
73 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Appendix ATechnical specifications This appendix lists the technical specifications for the breaker interface panel. This appendix covers the following topics: • “Environmental ” (next) • “Electrical” on page 74...
74 Appendix A Technical specifications 312755-G Rev 00 Electrical Physical dimensions Electromagnetic emissions Safety agency certification Parameter Specifications Input Voltage (Nominal) -48 VDC Input Current Feed Rating 60 A per DC input feed Output Current Feed Rating 30 A per DC output feed Par...
76 Appendix B BIP external cable pin assignments 312755-G Rev 00 Figure 46 J1 and J2 shelf alarm connector pinouts Table 6 lists the pin assignments for the J1 and J2 shelf alarm connectors. Table 6 J1 and J2 shelf alarm connector pin assignments Pin Signal Description 1 L+ABS Alarm battery supply r...
Appendix B BIP external cable pin assignments 77 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Office alarm connectors (J3 and J4) The BIP office alarm connectors (J3 and J4) use high-density, 26-pin D-sub connectors ( Figure 47 ). Figure 47 J3 and J4 high-den...
78 Appendix B BIP external cable pin assignments 312755-G Rev 00 Table 7 lists the pin assignments for the J3 and J4 office alarm connectors. Table 7 J3 and J4 office alarm connector pin assignments Pin Signal Description 1 TTA Voice communications from telephone jacks. 2 TRB Voice communications fr...
Appendix B BIP external cable pin assignments 79 Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis Standalone office alarm connector (J5) The standalone office alarm connectors (J5) uses a high-density, 26-pin D-sub connector ( Figure 49 ). Figure 49 J5 high-densi...
80 Appendix B BIP external cable pin assignments 312755-G Rev 00 Table 8 lists the pin assignments for the J5 standalone office alarm connector. Table 8 J5 standalone office alarm connector pin assignments Pin Signal Description 1 Critical alarm—Visual (NC) Visual alarm contact 2 Major alarm—Visual ...
Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis 81 Index Numbers 8691omSF central processing unit (CPU) 23 8691SF central processing unit (CPU) 23 A alarm module alarm conditions 23 configuring jumpers 30 display panel 22 LEDs 22 alarms aisle 26 central office 2...
Nortel Manuals
-
Nortel ELO ES24
Manual
- Nortel S5100 Manual
-
Nortel BSG12aw
Manual
-
Nortel 2332
Manual
-
Nortel M 901
Manual
- Nortel M3310 Manual
-
Nortel NN43001-307
Manual
-
Nortel 60-12T
Manual
-
Nortel 5580
Manual
-
Nortel NN43113-106
Manual
-
Nortel 3456
Manual
-
Nortel 1100 Series
Manual
-
Nortel 10396EA
Manual
-
Nortel 3395A
Manual
-
Nortel IP 560
Manual
-
Nortel BSR252
Manual
-
Nortel 5399
Manual
- Nortel S1100PJ Manual
-
Nortel P0941753 02
Manual
-
Nortel 8000
Manual