ii Copyright © 2000 Nortel Networks All rights reserved. April 2000. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express ...
Page 3 - Japan/Nippon Requirements Only; Taiwan Requirements; Canada Requirements Only
iii Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement Taiwan Requirements Bureau of Standards, Metrology and Inspection (BSMI) Statement Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus (Pass...
Page 5 - About this Guide
1 About this Guide This guide provides information about installing and using the Passport ™ 8010 Chassis. It includes the following information: • Requirements for the operating environment of the chassis • Instructions for attaching rack-mounting brackets • Instructions for installing the chassis ...
Page 6 - Before You Begin
2 Before You Begin The physical requirements for installing the Passport 8010 Chassis in an equipment rack are: For table or shelf installation, make sure the surface will support at least 225 pounds (101 kilograms). Make sure the area where you will install and use the Passport 8010 Chassis meets t...
Page 7 - Unpacking
3 Unpacking 1 = Passport 8010 Chassis2 = Power Supply (one or more—ordered separately)3 = Documentation4 = Power cord (optional)5 = DB-25 to DB-9 adapter for use with comm port cable6 = Comm port cable for Passport 8132TX module, purchased separately7 = Rack mounting brackets8 = Screws for brackets ...
Page 8 - Attaching the Rack-Mounting Brackets; Required tool: Phillips screwdriver
4 Attaching the Rack-Mounting Brackets Required tool: Phillips screwdriver 1. Hold each rack-mounting bracket against one side of the chassis. Make sure the attachment holes in the bracket match the holes in the chassis. 2. Insert the supplied flat-head screws to fasten each bracket to the chassis. ...
Page 9 - Installing the Chassis in a Rack; Slide the chassis into the rack.
5 Installing the Chassis in a Rack Required tool: Phillips screwdriver 1. Slide the chassis into the rack. 2. Insert and tighten the rack-mounting screws. To complete the installation process, refer to “Installing the Power Supply.” 9074FA 9075FA
Page 10 - Installing the Power Supply; Push the supply firmly into the bay.
6 Installing the Power Supply Required tool: Phillips screwdriver 1. If necessary, remove the filler panel from a power supply bay. 2. Push the supply firmly into the bay. 8957FA 8958FA Note: If you are installing a power supply in a new chassis, be sure to remove the bag of dessicant from the middl...
Page 11 - Turn on the power switch.; Operational Notes for the Power Supply
7 5. Turn on the power switch. 8964FA Note: In a newly installed chassis that requires two power supplies (nonredundant configuration), you must turn on both units within 2 seconds of each other. If you wait longer to turn on the second power supply, both power supplies will turn off. To correct thi...
Page 12 - Attaching a Cable Guide; Slide the guide onto the loosened screws.
8 Attaching a Cable Guide Attach the cable guides to the left side of the chassis so the bundled cables will not obstruct airflow to the right side of the chassis. 1. Loosen, but do not remove, the rack-mounting screws needed to install one cable guide. 2. Slide the guide onto the loosened screws. 9...
Page 13 - Installing a Module; Remove a filler panel from a module slot.
9 Installing a Module For details about the operation of modules, refer to the documentation that was shipped with each module. Required tool: Phillips screwdriver 1. Remove a filler panel from a module slot. 2. Make sure the inserter/extractor levers are rotated away from the front of the module. 9...
Page 14 - Align and tighten the retaining screws.; Chassis Specifications
10 5. Align and tighten the retaining screws. 9071FA Chassis Specifications Environmental Specifications Operating temperature: 0 ° to 40 ° C (32 ° to 104 ° F) Storage temperature: –25 ° to 70 ° C (–13 ° to 158 ° F) Operating humidity: 85% maximum relative humidity, noncondensing Storage humidity: 9...