Page 3 - CallPilot
CallPilot Installation and ConfigurationPart 2: 703t Server Hardware Installation Publication number: 555-7101-226 Product release: 2.02 Document release: Standard 1.01 Date: November 2005 Copyright © 2003 Nortel Networks. All Rights Reserved. Printed in Canada Information is subject to change witho...
Page 7 - Publication history
November 2005 Publication history Part 2: 703t Server Hardware Installation 7 Publication history November 2005 Standard 1.01 of the CallPilot Installation and Configuration, Part 2: 703t Server Hardware Installation is issued for general release. October 2003 Standard 1.0 of the CallPilot Installat...
Page 9 - Contents; 03t server description
Part 2: 703t Server Hardware Installation 9 Contents 1 703t server description 11 Server features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Slot assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1...
Page 11 - C h a p t e r 1; In this chapter
Part 2: 703t Server Hardware Installation 11 C h a p t e r 1 703t server description In this chapter Server features 12 Slot assignments 19 IRQ mapping table 21 Network connectivity 23 Supported peripheral devices 28
Page 12 - Introduction
703t server description Standard 1.01 12 CallPilot Server features Introduction This section provides a general overview of the 703t server. Server dimensions Height chassis only: 42 cm (16.75 in.) with chassis feet: 44 cm (17.5 in.) Width chassis only: 21.5 cm (8.6 in.) with chassis feet: 32 cm (12...
Page 13 - Front panel features
November 2005 703t server description Part 2: 703t Server Hardware Installation 13 Front panel features The following diagram shows the 703t server’s front panel features: G101759 CD-ROM drive CD drawer eject button Tape drive Network LEDs Sleep mode button (not used) Power buttonStatus LEDs USB con...
Page 16 - Rear panel diagram
703t server description Standard 1.01 16 CallPilot Rear panel diagram The following diagram shows the 703t server’s rear panel features: Note: For more information, see “Slot assignments” on page 19. G101760 Power connector USB connectors(not used) PS/2 keyboard connector PS/2 mouse connector Serial...
Page 18 - Environmental specifications
703t server description Standard 1.01 18 CallPilot Environmental specifications Environmental condition Specification Operating temperature 10 ° C to 35 ° C (50 ° F to 95 ° F) Maximum rate of change must not exceed 10 ° C (50 ° F) per hour. Non-operating (storage) temperature -40 ° C to 70 ° C (-40 ...
Page 19 - Slot assignments
November 2005 703t server description Part 2: 703t Server Hardware Installation 19 Slot assignments Introduction The slot assignment tables show the physical location of boards inside the server, relative to other boards the order in which boards are installed (for example, board #1, 2, 3, and s...
Page 20 - Slot definition and numbering
703t server description Standard 1.01 20 CallPilot Slot definition and numbering In the following table, the term “slot” refers to the available slot openings in the chassis, not the PCI connectors inside the server. The slots are numbered from the bottom of the server to the top. Slot 1 is the bott...
Page 21 - IRQ mapping table
November 2005 703t server description Part 2: 703t Server Hardware Installation 21 IRQ mapping table The following table lists the assignments for each Interrupt Request (IRQ). You do not need this information for installation, but it may be useful for troubleshooting. Interrupt I/O APIC level Slot ...
Page 23 - Network connectivity
November 2005 703t server description Part 2: 703t Server Hardware Installation 23 Network connectivity Introduction This section describes how the 703t server can be integrated into your network. The integration depends on the type of switch you are using. Refer to: “Sample network setup: Meridia...
Page 24 - Sample network setup: Meridian 1
703t server description Standard 1.01 24 CallPilot Sample network setup: Meridian 1 The Meridian 1 switch can be one of the following: Option 11C or Option 11C Mini using fiber connections Option 51C Option 61C Options 81 and 81C The following diagram shows a CallPilot 703t server network se...
Page 25 - Sample network setup: Succession 1000
November 2005 703t server description Part 2: 703t Server Hardware Installation 25 Sample network setup: Succession 1000 The following diagram shows a CallPilot 703t server network setup with a Succession 1000 system: G101636 OptivityTelephony Manager PC Web-enabledCallPilot administrative PC Web-en...
Page 26 - Switch connectivity
703t server description Standard 1.01 26 CallPilot In the previous diagram, the telephony LAN (TLAN) provides IP connectivity between the Succession 1000 system and the i2004 Internet phonesets. The connection between the Call Server and Media Gateway can be point-to-point, or it can be through the ...
Page 27 - Network requirements; Remote access connectivity
November 2005 703t server description Part 2: 703t Server Hardware Installation 27 Network requirements Appropriate networking equipment must be available for both the CLAN and ELAN. The CLAN and ELAN must be properly configured for correct CallPilot operation. To ensure correct configuration, Norte...
Page 28 - Supported peripheral devices
703t server description Standard 1.01 28 CallPilot Supported peripheral devices Introduction This section identifies external devices that are supported by the 703t server. The following table describes the supported peripheral devices: Device Description Modem A 56 Kbps external modem (NTRH9078 in ...
Page 31 - C h a p t e r 2; Preinstallation requirements
Part 2: 703t Server Hardware Installation 31 C h a p t e r 2 Preinstallation requirements In this chapter Installation overview 32 Unpacking the 703t server 35 Removing the side cover 37 Inspecting the server interior 40 Replacing the side cover 42 Installing the chassis feet 44
Page 32 - Installation overview
Preinstallation requirements Standard 1.01 32 CallPilot Installation overview Introduction This section provides an overview of the steps required to install the 703t server and peripheral devices. For detailed instructions, see Chapter 3, “Installing the server and connecting the peripheral devices...
Page 34 - Conventions for warnings
Preinstallation requirements Standard 1.01 34 CallPilot Conventions for warnings You may encounter the following types of warnings in this guide. Do not ignore them. . DANGER Risk of electric shock Warns you of an immediate electrical hazard, which, if not avoided, will result in shock, serious inju...
Page 35 - Unpacking the 703t server; To unpack the equipment
November 2005 Preinstallation requirements Part 2: 703t Server Hardware Installation 35 Unpacking the 703t server Introduction Follow this procedure to unpack the server and peripherals. To unpack the equipment 1 Carefully open the cardboard carton containing the server. 2 Remove the server from the...
Page 37 - Removing the side cover
November 2005 Preinstallation requirements Part 2: 703t Server Hardware Installation 37 Removing the side cover Introduction This section describes how to remove the server’s side cover so that you can work with the interior components. The side cover is on the server’s left side when the front of t...
Page 40 - Inspecting the server interior
Preinstallation requirements Standard 1.01 40 CallPilot Inspecting the server interior Introduction Before you install the server, you should perform a visual inspection for loose components, foreign matter, or shipping damage inside the server. To inspect the server interior 1 Ensure that all the c...
Page 42 - Replacing the side cover
Preinstallation requirements Standard 1.01 42 CallPilot Replacing the side cover Introduction When you are satisfied that the server was not damaged during shipment, reinstall the side cover. To replace the side cover 1 Align the right edge of the server’s side cover with the inside ledge at the fro...
Page 44 - Installing the chassis feet
Preinstallation requirements Standard 1.01 44 CallPilot Installing the chassis feet Introduction You can install feet on the bottom of the server. The feet stabilize the server and will help prevent the server from accidentally falling over on its side. To install the chassis feet G101782 Towards ba...
Page 47 - C h a p t e r 3
Part 2: 703t Server Hardware Installation 47 C h a p t e r 3 Installing the server and connecting the peripheral devices In this chapter Installing the server 48 Preparing the modem 49 Connecting peripherals to the server 53 Connecting the server to the ELAN 57 Connecting the server to the CLAN (opt...
Page 48 - Installing the server
Installing the server and connecting the peripheral devices Standard 1.01 48 CallPilot Installing the server Introduction Before you install the 703t server, ensure that the chosen location meets the requirements identified on the “Site inspection checklist” provided in CallPilot Installation and Co...
Page 49 - Preparing the modem; Modem DIP switches
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 49 Preparing the modem Introduction You require a modem to support remote dial-up access to the CallPilot server. The modem also enables Nortel Networks technical support to connect to...
Page 51 - To set the modem DIP switches
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 51 To set the modem DIP switches Use a pair of tweezers or a small screwdriver to set the DIP switches as described in the “Change to” column of the following table: Note: ON is down. ...
Page 53 - Connecting peripherals to the server
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 53 Connecting peripherals to the server Introduction This section describes how to connect the monitor, keyboard, mouse, and modem to the server. Rear panel The peripheral device conne...
Page 55 - To connect the mouse, keyboard, and monitor to the server; To connect the modem to the server
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 55 To connect the mouse, keyboard, and monitor to the server 1 Place the monitor, keyboard, and mouse in the same location as the server. 2 Plug the keyboard and mouse into the appropr...
Page 57 - Connecting the server to the ELAN
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 57 Connecting the server to the ELAN Introduction Connect the CallPilot server to the Meridian 1 switch or Succession 1000 system using the Embedded LAN (ELAN). To connect the server t...
Page 59 - To connect the server to the CLAN
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 59 Connecting the server to the CLAN (optional) Introduction This section provides instructions to connect the server to the Customer LAN (CLAN). Note: The CLAN connection is optional....
Page 61 - Requirements
November 2005 Installing the server and connecting the peripheral devices Part 2: 703t Server Hardware Installation 61 Requirements For installation, you require a Phillips No. 1 screwdriver. To install the software feature key adapter 1 Ensure that there is no cable connected to the parallel port. ...
Page 62 - Connecting the server to power; Before you begin
Installing the server and connecting the peripheral devices Standard 1.01 62 CallPilot Connecting the server to power Before you begin Ensure that proper power and grounding are available for all the power outlets serving the CallPilot server and its associated peripherals. Power for these devices m...
Page 64 - To connect the server to power; To start the server
Installing the server and connecting the peripheral devices Standard 1.01 64 CallPilot To connect the server to power 1 Plug the server’s AC power cord into the server’s rear panel. 2 Plug the other end into a wall receptacle or power bar. To start the server 1 Press the server’s power switch to sta...
Page 67 - Index; Numerics
Part 2: 703t Server Hardware Installation 67 Index Numerics 703t server CLAN connection, establishing 59 connector 17 connections establishing 62 power 62 dimensions 12 ELAN connection, establishing 57 – 58 environmental specifications 18 feet, installing 44 – 45 front panel, description 13 – 15 har...