Nortel 214393-A - Manuals
Nortel 214393-A – Manual in PDF format online.
Manuals:
Manual Nortel 214393-A
Summary
3 Reference for the BayStack 380-24F Gigabit Switch Management Software SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.In addition, the pro...
5 Reference for the BayStack 380-24F Gigabit Switch Management Software Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
6 Contents 214393-A Telneting to a switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Opening the Web-based management home page . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Trap log . . . . . . . . . . . . . . . . . . . . . . ...
Contents 7 Reference for the BayStack 380-24F Gigabit Switch Management Software VLAN tab for multiple ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Graphing port statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
8 Contents 214393-A Chapter 8RMON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Working with RMON information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Viewing statistics . . . . . . . . . . ....
9 Reference for the BayStack 380-24F Gigabit Switch Management Software Figures Figure 1 Device Manager window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 2 Properties dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2...
13 Reference for the BayStack 380-24F Gigabit Switch Management Software Tables Table 1 Properties dialog box items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 2 SNMP community string default values . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 3 Ope...
15 Reference for the BayStack 380-24F Gigabit Switch Management Software Preface Welcome to the Nortel Networks * Device Manager software, a set of graphical network management applications you can use to configure and manage the Nortel Networks BayStack * 380-24F Gigabit Switch. This guide provides...
16 Preface 214393-A Related publications For more information about using the BayStack 380-24F Gigabit Switch, refer to the following publications: • Using the BayStack 380-24F Gigabit Switch (part number 214391-A) Describes how to install and use the BayStack 380-24F Gigabit Switch; includes instru...
Preface 17 Reference for the BayStack 380-24F Gigabit Switch Management Software How to get help If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance. If you...
19 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 1Device Manager basics This chapter describes basic procedures for using the Device Manager software. The chapter includes the following information: • Instructions to start Device Manager, set the Device Manager proper...
20 Chapter 1 Device Manager basics 214393-A Figure 1 Device Manager window Setting the Device Manager properties Device Manager communicates with the BayStack 380-24F switch using Simple Network Management Protocol (SNMP). The software is shipped with default values set for important communication p...
Chapter 1 Device Manager basics 21 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 2 Properties dialog box 2 Type information and select check boxes. 3 Click OK. Table 1 describes the Properties dialog box items.
22 Chapter 1 Device Manager basics 214393-A Table 1 Properties dialog box items Area Item Description Polling Status Interval Interval at which status information is gathered (default is 20 seconds). (If Traps, Status Interval: ) Interval at which statistics and status information are gathered when ...
Chapter 1 Device Manager basics 23 Reference for the BayStack 380-24F Gigabit Switch Management Software Opening a device “Opening” a device displays the device view, a picture of the device. To open the device view, you must enter community strings that determine the access level granted to the dev...
24 Chapter 1 Device Manager basics 214393-A Figure 3 Open Device dialog box Table 3 describes the Open Device dialog box fields. 2 In the Device Name text box, type the DNS name or IP address of the device. Table 3 Open Device dialog box fields Field Description Device Name Either an IP address or a...
Chapter 1 Device Manager basics 25 Reference for the BayStack 380-24F Gigabit Switch Management Software 3 In the Read Community and Write Community text boxes, type the proper community strings. 4 Click Open. Device Manager automatically determines what version of software the selected device is ru...
26 Chapter 1 Device Manager basics 214393-A Figure 5 Parts of the Device Manager window Menu bar Use the menu bar to set up and operate Device Manager ( Table 4 ). Table 4 Menu bar commands Command Description Device Opens the Open Device dialog box. Edit Opens edit dialog boxes for selected objects...
Chapter 1 Device Manager basics 27 Reference for the BayStack 380-24F Gigabit Switch Management Software Toolbar The toolbar contains buttons that provide quick access to commonly used commands and some additional actions. Device view The device view allows you to determine at a glance the operating...
28 Chapter 1 Device Manager basics 214393-A Selecting objects The types of objects contained in the device view are: • A switch (called a unit in the menus and dialog boxes) • Min-GBIC ports • GBIC ports Figure 6 Objects in the device view Selecting a single object To select a single object: ➨ Click...
Chapter 1 Device Manager basics 29 Reference for the BayStack 380-24F Gigabit Switch Management Software Selecting multiple objects To select multiple objects of the same type (such as GBIC ports or or mini-GBIC ports): ➨ For a block of contiguous ports, drag to select the group of mini-GBIC ports. ...
30 Chapter 1 Device Manager basics 214393-A Figure 7 Color port legend Shortcut menus Each object in the device view has a shortcut menu that opens when you right-click a selected object. The switch unit shortcut menu (Figure 8) provides access to basic hardware information about the switch and to t...
Chapter 1 Device Manager basics 31 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 9 Port shortcut menu Table 8 describes the commands on the port shortcut menu. Status bar The status bar displays error and informational messages from the software application. These mess...
32 Chapter 1 Device Manager basics 214393-A Using the buttons in Device Manager dialog boxes Table 9 describes buttons in Device Manager dialog boxes. Not all buttons appear in all dialog boxes. Table 9 Device Manager buttons Button Name Description Insert Opens a dialog box to create a new entry fo...
Chapter 1 Device Manager basics 33 Reference for the BayStack 380-24F Gigabit Switch Management Software Editing objects You can edit objects and values in the Device Manager device view in the following ways: • Select an object and, on the toolbar, click the Edit Selected button. The edit dialog bo...
34 Chapter 1 Device Manager basics 214393-A Types of statistics The data tables in the statistics dialog boxes list the counters, or categories of statistics being gathered, for the specified object. For example, the categories for ports include Interface, Ethernet Errors, Bridge, and Rmon. Each cat...
Chapter 1 Device Manager basics 37 Reference for the BayStack 380-24F Gigabit Switch Management Software Statistics for single and multiple objects Statistics for a selected object or objects are displayed in the statistics dialog box. The dialog box for a single object shows all six types of statis...
38 Chapter 1 Device Manager basics 214393-A To change the type of statistics displayed, select a different type from the show list at the bottom of the dialog box. The statistics are updated based on the poll interval shown at the bottom of the dialog box. You can select a different polling interval...
Chapter 1 Device Manager basics 39 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 16 Statistics dialog box for a port 3 Select a tab for the group of statistics you want to view. 4 On the displayed data table, drag to select the cells you want to graph. (They must be in...
40 Chapter 1 Device Manager basics 214393-A Table 11 describes the buttons in the graph dialog boxes. Telneting to a switch From Device Manager, you can initiate a Telnet session to the console interface for the switch you are currently accessing. To Telnet to a switch: ➨ Do one of the following: • ...
Chapter 1 Device Manager basics 41 Reference for the BayStack 380-24F Gigabit Switch Management Software Opening the Web-based management home page From Device Manager, you can access the Web-based management home page. To open the Web-based management home page: ➨ Do one of the following: • From th...
42 Chapter 1 Device Manager basics 214393-A Trap log You can configure a BayStack 380-24F Switch to send SNMP generic traps. When Device Manager is running, any traps received are recorded in the trap log. You set the maximum number of entries in the trap log using the Properties dialog box ( Figure...
Chapter 1 Device Manager basics 43 Reference for the BayStack 380-24F Gigabit Switch Management Software Online Help Online Help in Device Manager is context-sensitive. You use a Web browser to display online Help. The Web browser should launch automatically when you click the Help button. If the He...
45 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 2Configuring and graphing the switch The first three sections of this chapter describe how you can use Device Manager to configure your switch. The last section describes how to use Device Manager to graph switch statis...
46 Chapter 2 Configuring and graphing the switch 214393-A Figure 19 Globals tab Table 13 describes the Globals tab items. Addresses tab The Addresses tab shows the IP address information for the device. To open the Addresses tab: 1 From the Device Manager main menu, choose Edit > IP. The IP dialo...
Chapter 2 Configuring and graphing the switch 47 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 20 Edit IP dialog box — IP Address tab Table 14 describes the IP Address tab items. ARP tab The Address Resolution Protocol (ARP) tab shows the MAC addresses and the associat...
48 Chapter 2 Configuring and graphing the switch 214393-A Figure 21 Edit IP dialog box — ARP tab Table 15 describes the ARP tab items. Table 15 ARP tab items Item Description Interface The device unit number. MacAddress The unique hardware address of the device. IpAddress The Internet Protocol addre...
Chapter 2 Configuring and graphing the switch 49 Reference for the BayStack 380-24F Gigabit Switch Management Software Editing the chassis configuration You can edit a chassis configuration from the Edit Chassis dialog box ( Figure 22 on page 50 ). To open the Chassis dialog box: 1 Select the chassi...
50 Chapter 2 Configuring and graphing the switch 214393-A Figure 22 Edit Chassis dialog box — System tab Table 16 describes the System tab items. Note: The chassis keeps track of the elapsed time and calculates the time and date using the system clock of the Device Manager machine as a reference. Ta...
Chapter 2 Configuring and graphing the switch 51 Reference for the BayStack 380-24F Gigabit Switch Management Software AuthenticationTraps Click enable or disable. When you select enabled, SNMP traps are sent to trap receivers for all SNMP access authentication. When you select disabled, no traps ar...
52 Chapter 2 Configuring and graphing the switch 214393-A Base Unit Info tab The Base Unit Info tab provides read-only information about the operating status of the hardware and whether or not the default factory settings are being used. To open the Base Unit Info tab: 1 Select the chassis. 2 From t...
Chapter 2 Configuring and graphing the switch 53 Reference for the BayStack 380-24F Gigabit Switch Management Software Agent tab The Agent tab provides read-only information about the addresses that the agent software uses to identify the switch. To open the Agent tab: 1 Select the chassis. 2 From t...
54 Chapter 2 Configuring and graphing the switch 214393-A Table 18 describes the Agent tab fields. Table 18 Agent tab fields Item Description NextBootpAddr The IP address of the BootP server to be used the next time the switch is booted. NextBootNetMask The subnet mask to be used the next time the s...
Chapter 2 Configuring and graphing the switch 55 Reference for the BayStack 380-24F Gigabit Switch Management Software SNMP tab The SNMP tab provides read-only information about the addresses that the agent software uses to identify the switch. To open the SNMP tab: 1 Select the chassis. 2 From the ...
56 Chapter 2 Configuring and graphing the switch 214393-A Table 19 describes the SNMP Info tab fields. Trap Receivers tab The Trap Receivers tab lists the devices that will receive SNMP traps from the BayStack 380-24F switch. To open the Trap Receivers tab: 1 Select the chassis. 2 From the shortcut ...
Chapter 2 Configuring and graphing the switch 57 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 20 describes the Trap Receivers tab items. Adding a Trap Receiver To edit the network traps table: 1 In the Trap Receivers tab (Figure 26) , click Insert. The Chassis, Insert ...
58 Chapter 2 Configuring and graphing the switch 214393-A Power Supply tab The Power supply tab provides read-only information about the operating status of the switch power supply. To open the Power supply tab: 1 Select the chassis. 2 From the shortcut menu, choose Edit > Chassis. The Chassis di...
Chapter 2 Configuring and graphing the switch 59 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 21 describes the Power supply tab fields. Table 21 Power supply tab fields Field Description Desc The power supply type. OperStat The operational state of the power supply. Va...
60 Chapter 2 Configuring and graphing the switch 214393-A Fan tab The Fan tab provides read-only information about the operating status of the switch fans. To open the Fan tab: 1 Select the chassis. 2 From the shortcut menu, choose Edit > Chassis. The Chassis dialog box opens ( Figure 22 on page ...
Chapter 2 Configuring and graphing the switch 61 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 22 describes the Fan tab fields. Working with configuration files You can view information and upload or download the configuration and image files from the Edit FileSystem di...
62 Chapter 2 Configuring and graphing the switch 214393-A Figure 30 FileSystem dialog box Table 23 describes the FileSystem dialog box items. Table 23 FileSystem dialog box items Item Description LoadServerAddr The IP address of the load server for the configuration file and/or the image file. If no...
Chapter 2 Configuring and graphing the switch 63 Reference for the BayStack 380-24F Gigabit Switch Management Software Graphing chassis statistics To graph chassis statistics: 1 Select the chassis. 2 Do one of the following: • From the shortcut menu, choose Graph. • From Device Manager main menu, ch...
64 Chapter 2 Configuring and graphing the switch 214393-A Six columns provide the statistics for the counters that are listed on the tab. For descriptions of the chassis IP statistics, refer to Table 10 on page 34 . SNMP tab The chassis SNMP tab lists chassis statistics. To open the SNMP tab: 1 Sele...
Chapter 2 Configuring and graphing the switch 65 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 31 Graph Chassis dialog box — Chassis SNMP tab Table 24 describes the SNMP tab fields. Table 24 SNMP tab fields Field Description InPkts The total number of messages delivere...
66 Chapter 2 Configuring and graphing the switch 214393-A InGetRequests The total number of SNMP Get-Request PDUs that have been accepted and processed by the SNMP protocol. InGetNexts The total number of SNMP Get-Next PDUs accepted and processed by the SNMP protocol. InSetRequests The total number ...
Chapter 2 Configuring and graphing the switch 67 Reference for the BayStack 380-24F Gigabit Switch Management Software IP tab The IP tab shows IP information for the chassis. To open the IP tab: 1 Select the chassis. 2 Do one of the following: • From Device Manager main menu, choose Graph > Chass...
68 Chapter 2 Configuring and graphing the switch 214393-A Figure 32 Graph Chassis dialog box — IP tab Table 25 describes the Chassis IP tab fields Table 25 Chassis IP tab fields Field Description InReceives The total number of input datagrams received from interfaces, including those received in err...
70 Chapter 2 Configuring and graphing the switch 214393-A ICMP In tab The chassis ICMP In tab shows ICMP In statistics. To open the ICMP In tab: 1 Select the chassis. 2 Do one of the following: • From Device Manager main menu, choose Graph > Chassis. • From the shortcut menu, choose Graph. • On t...
Chapter 2 Configuring and graphing the switch 71 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 33 Graph Chassis dialog box — ICMP In tab Table 26 describes the ICMP In tab fields. Table 26 ICMP In tab fields Field Description SrcQuenchs The number of ICMP Source Quench...
72 Chapter 2 Configuring and graphing the switch 214393-A ICMP Out tab The chassis ICMP Out shows ICMP Out statistics. To open the ICMP Out tab: 1 Select the chassis. 2 Do one of the following: • From Device Manager main menu, choose Graph > Chassis. • From the shortcut menu, choose Graph. • On t...
Chapter 2 Configuring and graphing the switch 73 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 27 describes the ICMP Out tab fields. Table 27 ICMP Out tab fields Field Description SrcQuenchs The number of ICMP Source Quench messages sent. Redirects The number of ICMP Re...
74 Chapter 2 Configuring and graphing the switch 214393-A
75 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 3Configuring and graphing ports This chapter describes how you use Device Manager to configure and graph ports on a BayStack 380-24F Switch. The windows displayed when you configure a single port differ from the ones di...
76 Chapter 3 Configuring and graphing ports 214393-A The following sections provide a description of the tabs in the Edit Port dialog box, and details about each field on the tab. Interface tab for a single port The Interface tab shows the basic configuration and status of a single port. To view the...
Chapter 3 Configuring and graphing ports 77 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 28 describes the Interface tab items for a single port. Table 28 Interface tab items for a single port Field Description Index A unique value assigned to each interface. The value ...
78 Chapter 3 Configuring and graphing ports 214393-A VLAN tab for a single port The VLAN tab allows you to view the VLAN membership for a single port. To view the VLAN tab: 1 Select the port you want to edit. 2 Do one of the following: • Double-click the selected port • From the shortcut menu, choos...
Chapter 3 Configuring and graphing ports 79 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 29 describes the VLAN tab items. Table 29 VLAN tab items for a single port Item Description Type Indicates the type of VLAN port (Trunk or Access port). If the port is a trunk port...
80 Chapter 3 Configuring and graphing ports 214393-A STG tab for a single port In the Spanning Tree Group (STG) tab, you can view the status and modify the configuration of a port’s spanning tree parameters. To view the STG tab: 1 Select the port you want to edit. 2 Do one of the following: • Double...
Chapter 3 Configuring and graphing ports 81 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 30 describes the STG tab items. Table 30 STG tab items for a single port Item Description StgId The number of times this port has transitioned from the Learning state to the Forwar...
82 Chapter 3 Configuring and graphing ports 214393-A Configuring multiple ports You can graph port statistics from the graph port dialog box. To open the graph port dialog box: 1 Select the port or ports you want to edit. 2 Do one of the following: • From the shortcut menu, choose Edit. • From the D...
Chapter 3 Configuring and graphing ports 83 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Do one of the following: • From the shortcut menu, choose Edit. • From the Device Manager main menu, choose Edit > Port. • On the toolbar, click Edit. The Interface tab ( Figure 38 ...
84 Chapter 3 Configuring and graphing ports 214393-A VLAN tab for multiple ports The VLAN tab shows the VLAN membership for the selected ports. To view or edit the Interface tab for multiple ports: 1 Select the ports that you want to edit. [Ctrl] + left-click the ports that you want to configure. A ...
Chapter 3 Configuring and graphing ports 85 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Do one of the following: • From the shortcut menu, choose Edit. • From the Device Manager main menu, choose Edit > Port. • On the toolbar, click Edit. The Port dialog box for a mult...
86 Chapter 3 Configuring and graphing ports 214393-A Graphing port statistics You can graph statistics for either a single port or multiple ports from the graphPort dialog box. The windows displayed are identical for either single or multiple port configuration. To open the graphPort dialog box for ...
Chapter 3 Configuring and graphing ports 87 Reference for the BayStack 380-24F Gigabit Switch Management Software Figure 40 Interface tab for graphing ports Table 33 describes the Interface tab fields for graphing ports. Table 33 Port Interface tab fields for multiple ports Field Description ifInOct...
88 Chapter 3 Configuring and graphing ports 214393-A Ethernet Errors tab for graphing ports The port Ethernet Errors tab shows port Ethernet Errors statistics. To open the Ethernet Errors tab for graphing: 1 Select the port or ports you want to graph. To select multiple ports, [Ctrl] + left-click th...
Chapter 3 Configuring and graphing ports 89 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Do one of the following: • From the Device Manager main menu, choose Graph > Port. • From the shortcut menu, choose Graph. • On the toolbar, click Graph. The Port dialog box for a s...
90 Chapter 3 Configuring and graphing ports 214393-A Table 39 describes the Ethernet Errors tab fields. Table 34 Ethernet Errors tab fields Field Description AlignmentErrors A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the F...
92 Chapter 3 Configuring and graphing ports 214393-A Bridge tab The Bridge tab displays port frame statistics. To open the Bridge tab for graphing: 1 Select the port or ports you want to graph. To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appea...
Chapter 3 Configuring and graphing ports 93 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 35 describes the Bridge tab fields. RMON tab The RMON tab displays Ethernet statistics for graphing a port or ports. To open the RMON tab for graphing: 1 Select the port or ports y...
94 Chapter 3 Configuring and graphing ports 214393-A 2 Do one of the following: • From the Device Manager main menu, choose Graph > Port. • From the shortcut menu, choose Graph. • On the toolbar, click Graph. The Port dialog box for a single port ( Figure 35 on page 76 ) or for multiple ports ope...
Chapter 3 Configuring and graphing ports 95 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 36 describes the RMON tab fields. Table 36 RMON tab fields Field Description Octets The total number of octets of data (including those in bad packets) received on the network (exc...
96 Chapter 3 Configuring and graphing ports 214393-A <=64 The total number of packets (including bad packets) received that were less than or equal to 64 octets in length (excluding framing bits but including FCS octets). 65 - 127 The total number of packets (including bad packets) received that ...
97 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 4Setting up MultiLink Trunk ports MultiLink Trunking (MLT) is a point-to-point connection that aggregates multiple ports so that they logically act like a single port with the aggregated bandwidth. Grouping multiple por...
Chapter 4 Setting up MultiLink Trunk ports 99 Reference for the BayStack 380-24F Gigabit Switch Management Software Adding ports to a MultiLink Trunk To add ports to an existing MLT: 1 From the Device Manager menu bar, choose VLAN > MLT. The MLT dialog box opens ( Figure 44 on page 98 ). 2 Double...
100 Chapter 4 Setting up MultiLink Trunk ports 214393-A Figure 46 MLT Statistics — Interface tab Table 38 describes the fields in the Interface tab. Table 38 Interface tab fields Field Description InMulticastPkt The number of packets delivered to this MLT that were addressed to a multicast address a...
Chapter 4 Setting up MultiLink Trunk ports 101 Reference for the BayStack 380-24F Gigabit Switch Management Software MultiLink Trunk Ethernet error statistics To view MultiLink Trunk Ethernet error statistics: 1 From the Device Manager menu bar, choose VLAN > MLT. The MLT dialog box opens ( Figur...
102 Chapter 4 Setting up MultiLink Trunk ports 214393-A Table 39 describes the fields in the Ethernet Errors tab. Table 39 Ethernet Errors tab fields Field Description AlignmentErrors A count of frames received on a particular MLT that are not an integral number of octets in length and do not pass t...
104 Chapter 4 Setting up MultiLink Trunk ports 214393-A
105 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 5Creating and managing VLANs This chapter describes using Device Manager to manage VLANs on your BayStack 380-24F Gigabit Switch. The chapter covers creating, editing, and deleting VLANs. It includes the following sect...
106 Chapter 5 Creating and managing VLANs 214393-A Creating VLANs Device Manager enables you to create a port-based VLAN. VLAN Information To open the VLAN dialog box: ➨ From the Device Manager menu bar, choose VLAN > VLANs. The VLAN dialog box opens ( Figure 48 ). Figure 48 VLAN dialog box Table...
Chapter 5 Creating and managing VLANs 107 Reference for the BayStack 380-24F Gigabit Switch Management Software Creating a port-based VLAN To create a port-based VLAN: 1 From the Device Manager menu bar, choose VLAN > VLANs. The VLAN dialog box opens ( Figure 48 on page 106 ). 2 Click Insert. The...
108 Chapter 5 Creating and managing VLANs 214393-A Accepting untagged frames In the BayStack 380-24F, you configure whether or not untagged frames are sent or received on the port level. Refer to “VLAN tab for a single port” on page 78 for VLAN tab field descriptions. You can select whether or not t...
Chapter 5 Creating and managing VLANs 109 Reference for the BayStack 380-24F Gigabit Switch Management Software Modifying and managing existing VLANs The main dialog box for managing VLANs in Device Manager is the VLAN dialog box. To open the VLAN dialog box: ➨ From the Device Manager main menu, cho...
111 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 6Setting up bridging The Bridge parameters allow you to view MAC address table for a Baystack 380-24F Gigabit Switch. This chapter describes the bridge information available in Device Manager on the following tab: • Ba...
112 Chapter 6 Setting up bridging 214393-A Figure 52 Base tab Table 42 describes the Base tab fields. Spanning Tree tab The Spanning Tree tab displays the version of the spanning tree protocol currently running. If future versions of the IEEE spanning tree protocol are released that are incompatible...
Chapter 6 Setting up bridging 113 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Click the Spanning Tree tab. The Spanning Tree tab opens (Figure 53) . Figure 53 Spanning Tree tab
114 Chapter 6 Setting up bridging 214393-A Table 43 describes the Spanning Tree tab fields. Table 43 Spanning Tree tab fields Field Description ProtocolSpecification Version of the spanning tree protocol being run. Values include: • decLb100: Indicates the DEC LANbridge 100 spanning tree protocol. •...
Chapter 6 Setting up bridging 115 Reference for the BayStack 380-24F Gigabit Switch Management Software Transparent tab The Transparent tab contains information about a specific unicast MAC address, which has some forwarding information for the bridge. To view the Transparent tab: 1 From the Device ...
116 Chapter 6 Setting up bridging 214393-A The Bridge dialog box opens, with the Base tab displayed. 2 Click the Transparent tab. The Transparent tab opens (Figure 54) . Figure 54 Transparent tab Table 44 describes the Transparent tab items. Forwarding tab The Forwarding tab displays the current sta...
Chapter 6 Setting up bridging 117 Reference for the BayStack 380-24F Gigabit Switch Management Software To view the Forwarding tab: 1 From the Device Manager menu bar, choose Edit > Bridge. The Bridge dialog box opens, with the Base tab displayed. 2 Click the Forwarding tab. The Forwarding tab op...
118 Chapter 6 Setting up bridging 214393-A Table 45 describes the Forwarding tab fields. Table 45 Forwarding tab fields Field Description Status The values of this fields include: • invalid: Entry is no longer valid, but has not been removed from the table. • learned: Value of the corresponding inst...
119 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 7Troubleshooting Device Manager This chapter describes diagnostic information available in Device Manager on the following tabs: • Topology tab (next) • Topology Table tab ( page 120 ) Topology tab To view topology inf...
120 Chapter 7 Troubleshooting Device Manager 214393-A Table 46 describes the Topology tab items. Topology Table tab To view more topology information: 1 From the Device Manager menu bar, choose Edit > Diagnostics. The Diagnostics dialog box opens with the Topology tab displayed ( Figure 56 on pag...
Chapter 7 Troubleshooting Device Manager 121 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 47 describes the Topology Table tab fields. Table 47 Topology Table tab fields Field Description Slot The slot number in the chassis in which the topology message was received. Po...
122 Chapter 7 Troubleshooting Device Manager 214393-A
123 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 8RMON The Remote Network Monitoring (RMON) MIB is an interface between the RMON agent on a BayStack 380-24F Gigabit Switch and an RMON management application, such as the Device Manager. It defines objects that are sui...
124 Chapter 8 RMON 214393-A 2 Do one of the following: • Double-click on the selected port • From the shortcut menu, choose Graph. • From the Device Manager main menu, choose Graph. The Graph Port dialog box opens with the Interface tab displayed ( Figure 35 on page 76 ). 3 Click the RMON tab. The R...
Chapter 8 RMON 125 Reference for the BayStack 380-24F Gigabit Switch Management Software • Buckets are gathered at 30-minute intervals. • Number of buckets gathered is 50. Both the time interval and the number of buckets is configurable. However, when the last bucket is reached, bucket 1 is dumped a...
126 Chapter 8 RMON 214393-A Creating a history You can use RMON to collect statistics at intervals. For example, if you want RMON statistics to be gathered over the weekend, you will want enough buckets to cover two days. To do this, set the history to gather one bucket each hour, thus covering a 48...
Chapter 8 RMON 127 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Select an index and then click Insert. The RMONControl, Insert History dialog box opens (Figure 61) . Figure 61 RMONControl, Insert History dialog box Table 48 History tab fields Field Description Index A uniq...
128 Chapter 8 RMON 214393-A 3 Select the port from the port list or type the port number. 4 Set the number of buckets. The default is 50. 5 Set the interval. The default is 1800 seconds. 6 Type the owner, the network management system that created this entry . 7 Click Insert. RMON collects statistic...
Chapter 8 RMON 129 Reference for the BayStack 380-24F Gigabit Switch Management Software Enabling Ethernet statistics gathering You can use RMON to gather Ethernet statistics. To gather Ethernet statistics: 1 From the Device Manager main menu, choose RMON > Control. The RMONControl dialog box ope...
130 Chapter 8 RMON 214393-A 3 Click Insert. The RMONControl, Insert Ether Stats dialog box opens (Figure 63) . Figure 63 RMONControl, Insert Ether Stats dialog box 4 Select the port(s). Enter the port number you want or select the port from the list menu (Figure 64) . Figure 64 RMONControl, Insert E...
Chapter 8 RMON 131 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 Click the Ether Stats tab. The Ether Stats tab opens ( Figure 63 on page 130 ). 3 Highlight the row that contains the port ID you want to delete. 4 Click Delete. The Ether Stats entry is removed from the table...
132 Chapter 8 RMON 214393-A Figure 65 How alarms fire It is important to note that the alarm fires during the first interval that the sample goes out of range. No additional events are generated for that threshold until the opposite threshold is crossed. Therefore, it is important to carefully defin...
Chapter 8 RMON 133 Reference for the BayStack 380-24F Gigabit Switch Management Software spanning tree is disabled (which would cause the value for outbound octets to drop to zero), the falling alarm cannot fire because the baseline traffic is always greater than the value of the falling threshold. ...
134 Chapter 8 RMON 214393-A and allows for the detection of threshold crossings that span the sampling boundary. If you track the current values of a given delta-valued alarm and add them together, therefore, the result is twice the actual value. (This result is not an error in the software.) Alarm ...
Chapter 8 RMON 135 Reference for the BayStack 380-24F Gigabit Switch Management Software 2 In the variable field, select a variable for the alarm from the list and a port (or other ID) on which you want to set an alarm ( Figure 68 ). Figure 68 Alarm variable list Alarm variables are in three formats...
136 Chapter 8 RMON 214393-A If you want to make field changes, see the field descriptions shown in Table 50 . To view the RMON statistics and history for the port for which you have created an alarm: 1 Select the port on which you have created an alarm. 2 From the Device Manager main menu, choose RM...
Chapter 8 RMON 137 Reference for the BayStack 380-24F Gigabit Switch Management Software 3 Click the Ether Stats tab to view the statistics ( Figure 64 on page 130 ). Alarms tab To view information about alarms: ➨ Click on RMON > Alarms The RMONAlarms dialog box opens with the Alarms tab ( Figure...
138 Chapter 8 RMON 214393-A To delete an alarm: 1 From the Device Manager main menu, choose RMON >Alarms. Value The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the difference between the samples at the beginning and end of t...
Chapter 8 RMON 139 Reference for the BayStack 380-24F Gigabit Switch Management Software The RMONAlarms dialog box opens with the Alarms tab ( Figure 69 ) displayed. 2 Click any field for the alarm that you want to delete to highlight it. 3 Click Delete. Events RMON events and alarms work together t...
140 Chapter 8 RMON 214393-A The Events tab opens ( Figure 70 ). Figure 70 RMONAlarms dialog box — Events tab Table 52 describes the RMONAlarms Events tab fields. Table 52 Events tab fields Field Description Index This index uniquely identifies an entry in the event table. Each entry defines one even...
Chapter 8 RMON 141 Reference for the BayStack 380-24F Gigabit Switch Management Software Creating an event To create an event: 1 In the RMONAlarms dialog box Events tab, click Insert. The RMONAlarms, Insert Events dialog box opens (Figure 71) . Figure 71 Insert Events dialog box 2 In the Description...
142 Chapter 8 RMON 214393-A Deleting an event To delete an event: 1 In the Events tab, highlight an event Description. 2 Click Delete. The event is removed from the table. Log information The Log tab chronicles and describes the alarm activity, which is then generated to viewed. To view the Log tab:...
Chapter 8 RMON 143 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 53 describes the Log tab fields. Table 53 Log tab fields Item Description Time An implementation-dependent description of the event that activated the log entry. Description Specifies whether the event is ...
145 Reference for the BayStack 380-24F Gigabit Switch Management Software Chapter 9Security parameters You can set the security features for a switch so that the actions are performed by the software when a violation occurs. The security actions you specify are applied to all ports of the switch. Th...
146 Chapter 9 Security parameters 214393-A Figure 74 General tab Table 54 describes the General tab items. Table 54 General tab items Items Description AuthSecurityLock If this parameter is listed as “locked,” the agent refuses all requests to modify the security configuration. Entries also include:...
Chapter 9 Security parameters 147 Reference for the BayStack 380-24F Gigabit Switch Management Software SecurityAction Actions performed by the software when a violation occurs (when SecurityStatus is enabled). The security action specified here applies to all ports of the switch. A blocked address ...
148 Chapter 9 Security parameters 214393-A SecurityList tab The SecurityList tab contains a list of Security port items. To view the SecurityList tab: 1 From the Device Manager menu bar, select Edit > Security. The Security window opens with the General tab displayed ( Figure 74 on page 146 ). 2 ...
Chapter 9 Security parameters 149 Reference for the BayStack 380-24F Gigabit Switch Management Software Security, Insert SecurityList dialog box Security, Insert SecurityList dialog box has editable fields for the SecurityList tab. Each row in this dialog box has information that can be updated or c...
150 Chapter 9 Security parameters 214393-A AuthConfig tab The AuthConfig tab contains a list of boards, ports and MAC addresses that have the security configuration. An SNMP SET PDU for a row in the tab requires the entire sequence of the MIB objects in each entry to be stored in one PDU. Otherwise,...
Chapter 9 Security parameters 151 Reference for the BayStack 380-24F Gigabit Switch Management Software Table 57 describes the AuthConfig tab fields. Security, Insert AuthConfig dialog box Security, Insert AuthConfig dialog box has editable fields for the AuthConfig tab. Each row in this dialog box ...
152 Chapter 9 Security parameters 214393-A Figure 78 Security, Insert AuthConfig dialog box Table 58 describes the Security, Insert AuthConfig dialog box fields. Table 58 Security, Insert AuthConfig dialog box fields Item Description BrdIndx Index of the board. This corresponds to the index of the u...
Chapter 9 Security parameters 153 Reference for the BayStack 380-24F Gigabit Switch Management Software AuthStatus tab The AuthStatus tab displays information of the authorized boards and port status data collection. Information includes actions to be performed when an unauthorized station is detect...
154 Chapter 9 Security parameters 214393-A Figure 79 AuthStatus tab Table 59 describes the AuthStatus tab fields. Table 59 AuthStatus tab fields Item Description AuthStatusBrdIndx The index of the board. This corresponds to the index of the slot containing the board if the index is greater than zero...
Chapter 9 Security parameters 155 Reference for the BayStack 380-24F Gigabit Switch Management Software AuthViolation tab The AuthViolation tab contains a list of boards and ports where network access violations have occurred, and also the identity of the offending MAC addresses. To view the AuthVio...
156 Chapter 9 Security parameters 214393-A 2 Click the AuthViolation tab. The AuthViolation tab opens (Figure 80) . Figure 80 AuthViolation tab Table 60 describes fields for the AuthViolation tab fields. Table 60 AuthViolation tab fields Field Description BrdIndx The index of the board. This corresp...
Reference for the BayStack 380-24F Gigabit Switch Management Software 157 Index Symbols <=64 field 96 >1023 field 96 >127 field 96 >255 field 96 >511 field 96 >64 field 96 A AbsoluteValue statistics 34 access levels 23 Action field 63 Actions menu 26 ActiveMember field 106 ActiveMe...
Nortel Manuals
-
Nortel ELO ES24
Manual
- Nortel S5100 Manual
-
Nortel BSG12aw
Manual
-
Nortel 2332
Manual
-
Nortel M 901
Manual
- Nortel M3310 Manual
-
Nortel NN43001-307
Manual
-
Nortel 60-12T
Manual
-
Nortel 5580
Manual
-
Nortel NN43113-106
Manual
-
Nortel 3456
Manual
-
Nortel 1100 Series
Manual
-
Nortel 10396EA
Manual
-
Nortel 3395A
Manual
-
Nortel IP 560
Manual
-
Nortel BSR252
Manual
-
Nortel 5399
Manual
- Nortel S1100PJ Manual
-
Nortel P0941753 02
Manual
-
Nortel 8000
Manual