Nortel 201i - Manuals
Nortel 201i – Manual in PDF format online.
Manuals:
Manual Nortel 201i
Summary
Standard 1.07 2 CallPilot Copyright © 2006 Nortel Networks. All Rights Reserved. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented with...
Standard 1.07 4 CallPilot SONY is a trademark of Sony Corporation. SYBASE is a trademark of Sybase, Inc. TEAC is a trademark of TEAC Corporation. US ROBOTICS, the US ROBOTICS logo, and SPORTSTER are trademarks of US Robotics. WINZIP is a trademark of Nico Mark Computing, Inc. XEON is a trademark of ...
201i Server Hardware Installation 5 Publication history November 2006 Standard 1.07 of 201i Server Hardware Installation is released for CallPilot 4.0 general availability. October 2006 Standard 1.06 of 201i Server Hardware Installation is released for CallPilot 4.0 general availability. October 200...
6 CallPilot Publication history Standard 1.07 September 2002 Standard 1.0 of CallPilot Installation and Configuration, Part 2: 201i Server Hardware Installation is released for CallPilot 2.0 general availability.
201i Server Hardware Installation 9 Task List To unpack the 201i server ............................................................... 41To prepare the 201i server for installation in a Meridian 1 switch ... 52To position the 201i server on the switch shelf ............................... 56To remo...
201i Server Hardware Installation 11 Contents 1 How to get help 13 2 About the 201i server 15 201i server description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Network connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Contents Standard 1.07 12 CallPilot 6 Installing the 201i server in the Succession 1000 system 95 Succession 1000 description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Removing the Media Gateway or Media Gateway Expansion cover . . . . 104Installing the 201i server. ....
201i Server Hardware Installation 13 C h a p t e r 1 How to get help This section explains how to get help for Nortel products and services. Getting Help from the Nortel Web site The best way to get technical support for Nortel products is from the Nortel Technical Support Web site: http://www.norte...
How to get help Standard 1.07 14 CallPilot Outside North America, go to the following Web site to obtain the phone number for your region: http://www.nortel.com/callus Getting Help from a specialist by using an Express Routing Code To access some Nortel Technical Solutions Centers, you can use an Ex...
201i Server Hardware Installation 15 C h a p t e r 2 About the 201i server In this chapter 201i server description 16 Network connectivity 24 Peripheral connectivity 31
About the 201i server Standard 1.07 16 CallPilot 201i server description Introduction The 201i server is a flexible multimedia telephony server designed to integrate with Nortel Meridian 1 * and Succession * 1000 products. The 201i server occupies two slots of a Meridian 1 shelf or Succession 1000 M...
November 2006 About the 201i server 201i Server Hardware Installation 17 Two Ethernet controllers on the 201i server motherboard provide Ethernet capability. These controllers provide the network interfaces for both the embedded LAN (ELAN) and customer LAN (CLAN). The connections to the ELAN and CLA...
About the 201i server Standard 1.07 1 8 CallPilot The following diagram shows the 201i server components:. Heat sink Hard drive power cable Hard drive data cable Secondary backplane connector pin Secondary backplane connector 3.5-inch IDE hard drive Hard drive mounting bracket Software feature key(D...
November 2006 About the 201i server 201i Server Hardware Installation 19 Faceplate The following diagram shows the 201i server faceplate. The faceplate provides LEDs, MPC card slots, and connectors for peripheral devices: G10143 8 Lock latch Keyboard connector Mouse connector Infrared port (future u...
About the 201i server Standard 1.07 20 CallPilot The following table describes each faceplate feature: Faceplate feature Description Mouse connector The mouse connector is a standard PS/2 connector and is hot-pluggable. Lock latches Lock latches at the top and bottom of the faceplate secure the serv...
November 2006 About the 201i server 201i Server Hardware Installation 21 MPC card status LEDs (continued) On, then off: The MPC card has been successfully powered down. It is safe to remove the card. Note: For instructions on powering up or powering down the MPC card, see “Starting and stopping co...
About the 201i server Standard 1.07 22 CallPilot Environmental specifications Temperatures Relative humidity Network and drive activity LEDs (labeled as E, C, I, and S) The E and C LEDs indicate the presence of network activity for both the ELAN and CLAN interfaces (respectively). When they are lit,...
November 2006 About the 201i server 201i Server Hardware Installation 23 Absolute RH 20% to 80% RH (noncondensing) Long-term storage RH 5% to 95% RH [at –40 ° C (-40 ° F) to 70 ° C (158 ° F) respectively] (noncondensing)
About the 201i server Standard 1.07 24 CallPilot Network connectivity Introduction This section shows how CallPilot and the Meridian 1 or Succession 1000 system are integrated into your network. It also describes what is required in the network for correct CallPilot operation. Sample network setup: ...
About the 201i server Standard 1.07 26 CallPilot Sample network setup: Succession 1000 The following diagram shows an example of how the 201i server can be integrated with the Succession 1000 system in your network: G101630 OptivityTelephony Manager PC W eb-enabled CallPilot administrative PC W eb-e...
November 2006 About the 201i server 201i Server Hardware Installation 27 In the illustration on page 26, the telephony LAN (TLAN) provides IP connectivity between the Succession 1000 system and the i2004 Internet phonesets. The connection between the Call Server and Media Gateway can be point-to-poi...
About the 201i server Standard 1.07 2 8 CallPilot Network requirements Appropriate networking equipment must be available for both the CLAN and ELAN. The CLAN and ELAN must be properly configured for correct CallPilot operation. To ensure correct configuration, Nortel recommends that you consult a n...
November 2006 About the 201i server 201i Server Hardware Installation 29 The following table identifies the purpose of each connector on the NTRH0912 1 multi I/O cable. Note: Labels on the RJ-45 cables distinguish the CLAN and ELAN connectors. 1.For customers in EUED countries: see Appendix A, “RoHS...
November 2006 About the 201i server 201i Server Hardware Installation 31 Peripheral connectivity Introduction Peripheral equipment is attached to the 201i server on the server faceplate. Faceplate connections The following peripheral devices connect to the 201i server faceplate: monitor (SVGA) k...
About the 201i server Standard 1.07 32 CallPilot MPC-8 card The MPC-8 card looks like a Type II PC card, and supports the multimedia telephony services on the 201i server. Four specially-designed card slots are available for the MPC-8. All are located on the 201i server faceplate. SCSI connections T...
November 2006 About the 201i server 201i Server Hardware Installation 33 Note: The CD-ROM drive is not hot-pluggable. You must power off the server to connect or disconnect the drive. Tape drive (NTRH9038) An external SCSI tape drive is used to back up and restore data. The device connects to the se...
About the 201i server Standard 1.07 34 CallPilot Note: The mouse connector on the 201i faceplate is a PS/2 connector. If you plan to use a USB mouse with USB-to-PS/2 converter, you must also use the Nortel-supplied 101 mm (4-in) PS/2 extension cable (A0855616). Without the extension cable, the monit...
201i Server Hardware Installation 35 C h a p t e r 3 Preparing for installation In this chapter Installation overview 36 Unpacking and inspecting the 201i server 41 Switch and network requirements 44
Preparing for installation Standard 1.07 36 CallPilot Installation overview Introduction This section provides a high-level overview of the requirements and procedure for installing the 201i server. For a list of CallPilot documentation, see the document map on page 7. Before you begin Ensure that p...
November 2006 Preparing for installation 201i Server Hardware Installation 37 Installation checklist The following checklist identifies the steps required to install the 201i server and peripheral devices. For more details, see Chapter 8, “Connecting peripheral devices to the 201i server.” . WARNING...
Preparing for installation Standard 1.07 3 8 CallPilot 2 Familiarize yourself with the “Switch and network requirements” on page 44 of this guide. ❒ 3 If you are installing the 201i server into a Meridian 1 tiered system, do the following: Change the location of the secondary backplane (DS30X) con...
November 2006 Preparing for installation 201i Server Hardware Installation 39 6 Set the following: SCSI IDs on the CD-ROM and tape drives (see pages 126 and 128) DIP switches on the CD-ROM drive (see page 126) device termination on the CD-ROM and tape drives (see page 130) ❒ 7 Insert the 201i ...
Preparing for installation Standard 1.07 40 CallPilot 9 Connect the 201i server and devices as follows: Connect the monitor, keyboard, and mouse to the 201i server faceplate (see page 142). ❒ Connect the CD-ROM and tape drives to the intermediate SCSI cable (see page 144). ❒ Connect the multi ...
November 2006 Preparing for installation 201i Server Hardware Installation 41 Unpacking and inspecting the 201i server Introduction This section describes how to: unpack the 201i server and peripherals inspect the 201i server for damage It also describes what to do if you determine that the 201i...
Preparing for installation Standard 1.07 42 CallPilot To inspect the 201i server for shipping damage Before proceeding with the installation, visually inspect the 201i server for any damage that might have occurred during shipping. Ensure also that the items in the following checklists are secure: W...
November 2006 Preparing for installation 201i Server Hardware Installation 43 What’s next? Review the “Switch and network requirements” on page 44.
Preparing for installation Standard 1.07 44 CallPilot Switch and network requirements Introduction The information in this section will help you plan your 201i server installation. Meridian 1 or Succession 1000 slot requirements The 201i server occupies two physical and electrical slots. You must in...
November 2006 Preparing for installation 201i Server Hardware Installation 45 Meridian 1 I/O panel connections On large Meridian 1 systems (such as Option 51C), the 201i server requires two connections from the slots to the I/O panel on the rear of the switch, as follows: One connection is for the...
Preparing for installation Standard 1.07 46 CallPilot If the LAN is to be networked with the 201i server, you need a network specialist to ensure proper configuration. What’s next? Install the 201i server in the Meridian 1 switch or Succession 1000 system. For instructions, see one of the following:...
201i Server Hardware Installation 47 C h a p t e r 4 Installing the 201i server in a large Meridian 1 system In this chapter Overview 4 8 Repositioning the secondary backplane connector 50 Installing the 201i server in the large Meridian 1 switch 56 Removing the backplane (tip and ring) cables 5 8 I...
Installing the 201i server in a large Meridian 1 system Standard 1.07 4 8 CallPilot Overview Introduction This section describes how to install the 201i server in a Meridian 1 switch. Meridian 1 I/O panel connections On the Meridian 1, the 201i server requires two connections from the slots to the I...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 49 Backplane (tip and ring) cable The backplane (tip and ring) cable supplied with the 201i server (NTRH3501) provides 100Base-T Ethernet CLAN operation. This cable offers more network throughput ...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 51 Secondary backplane connector description The secondary backplane connector is attached to the backplane edge of the 201i server. It consists of the following items: connector screws pin ...
Installing the 201i server in a large Meridian 1 system Standard 1.07 52 CallPilot Required equipment To move the secondary backplane connector, you need a Phillips No. 1 screwdriver. A pair of needle-nosed pliers can also be helpful for removing the pin connector. To prepare the 201i server for ins...
Installing the 201i server in a large Meridian 1 system Standard 1.07 56 CallPilot Installing the 201i server in the large Meridian 1 switch Introduction The 201i server occupies two slots. You can install the 201i server in slots 0 through 14. Ensure that both slots have electrical backplane connec...
Installing the 201i server in a large Meridian 1 system Standard 1.07 5 8 CallPilot Removing the backplane (tip and ring) cables Introduction You must remove the Meridian 1 backplane (tip and ring) cables that are associated with the slots occupied by the 201i server so that you can install the foll...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 59 To remove the backplane cables 1 Remove the I/O panel cover from the rear of the Meridian 1 switch. 2 Remove the protective plate from the rear of the Meridian 1 switch. 3 Remove the existing b...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 61 The following diagram shows an example using slots 3 and 4: What’s next? Continue with “Installing the NTRH3501 backplane cable” on page 62. G101549 C B A
Installing the 201i server in a large Meridian 1 system Standard 1.07 62 CallPilot Installing the NTRH3501 backplane cable Introduction You must connect the backplane (tip and ring) cable supplied with the 201i server (NTRH3501) for 100Base-T Ethernet CLAN operation. This cable offers more network t...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 63 Before you begin Before you can install the NTRH3501 cable, you must remove the existing backplane cable from the back of the switch. See “Removing the backplane (tip and ring) cables” on page ...
Installing the 201i server in a large Meridian 1 system Standard 1.07 64 CallPilot See the following diagram: What’s next? Continue with “Installing the SCSI cables for Meridian 1” on page 65. G101550 Backplane cableNTRH3501 Multi I/O cableNTRH0912 UP 1 UP 2 UP 3 A B C
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 65 Installing the SCSI cables for Meridian 1 Introduction Before you can connect a CD-ROM or tape drive to the 201i server, you must install the SCSI cables. The SCSI cables route the SCSI connect...
Installing the 201i server in a large Meridian 1 system Standard 1.07 66 CallPilot The connector on the intermediate SCSI cable that attaches to the 201i server faceplate is a low-profile right-angle connector. This allows the cable to be attached with the Meridian 1 cabinet cover on. NTRH1410 (fo...
November 2006 Installing the 201i server in a large Meridian 1 system 201i Server Hardware Installation 67 In this diagram, the CD-ROM drive is the first device. The tape drive is the last device. Note: Alternate SCSI device connection scenarios are supported, but are not depicted in this guide. If ...
Installing the 201i server in a large Meridian 1 system Standard 1.07 6 8 CallPilot To install the SCSI cables for Meridian 1 1 Thread the SCSI connector end of the NTRH140 8 cable from the front of the Meridian 1 along the bottom of the shelf to either the left or the right access channel. 2 Leave ...
201i Server Hardware Installation 71 C h a p t e r 5 Installing the 201i server in an Option 11C or Option 11C Mini In this chapter Installing the 201i server in the Option 11C or Option 11C Mini switch 72 Section A: Installing Option 11C cables 77 Installing the intermediate SCSI cable for Option 1...
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 72 CallPilot Installing the 201i server in the Option 11C or Option 11C Mini switch Introduction The 201i server occupies physical and electrical slots. The 201i server must be installed in two peripheral equipment slots as...
November 2006 Installing the 201i server in an Option 11C or Option 11C Mini 201i Server Hardware Installation 75 What’s next? Continue with installing the cables. Refer to one of the following: Section A: “Installing Option 11C cables,” on page 77 Section B: “Installing Option 11C Mini cables,”...
November 2006 Installing the 201i server in an Option 11C or Option 11C Mini 201i Server Hardware Installation 77 Section A: Installing Option 11C cables In this section Installing the intermediate SCSI cable for Option 11C 7 8
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 8 0 CallPilot Note: Alternate SCSI device connection scenarios are supported, but are not depicted in this guide. If you want to use a connection scenario that is not described in this guide, ensure that you use appropriate...
November 2006 Installing the 201i server in an Option 11C or Option 11C Mini 201i Server Hardware Installation 8 1 To install the cable 1 Attach the bracket assembly and cable as follows: a. Below the card cage, temporarily remove the hardware that secures cable connections to the Option 11C. b. Tem...
November 2006 Installing the 201i server in an Option 11C or Option 11C Mini 201i Server Hardware Installation 8 5 Section B: Installing Option 11C Mini cables In this section Installing the NTRH3502 SCSI cable for Option 11C Mini 8 6 Installing cables on the back of the Option 11C Mini cabinet 92
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 8 6 CallPilot Installing the NTRH3502 SCSI cable for Option 11C Mini Introduction Before you can connect a CD-ROM or tape drive to the 201i server, you must install the NTRH3502 SCSI cable. The NTRH3502 SCSI cable routes th...
November 2006 Installing the 201i server in an Option 11C or Option 11C Mini 201i Server Hardware Installation 8 7 Note: Alternate SCSI device connection scenarios are supported, but are not depicted in this guide. If you want to use a connection scenario that is not described in this guide, ensure ...
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 88 CallPilot To install the NTRH3502 SCSI cable 1 If your Option 11C Mini is equipped with a Fiber Routing Guide, temporarily remove it. Note: For detailed instructions, refer to the Option 11C and Option 11C Mini Expansion...
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 90 CallPilot SCSI cable installation to accommodate the Fiber Routing Guide 6 If required, reinstall the Fiber Routing Guide. Note: For detailed instructions, refer to the Option 11C and Option 11C Mini Expansion Guide (NTP...
Installing the 201i server in an Option 11C or Option 11C Mini Standard 1.07 92 CallPilot Installing cables on the back of the Option 11C Mini cabinet Introduction The following items connect to the back of the Option 11C Mini cabinet: multi I/O cable (NTRH0912) Option 11C Mini power cord with t...
201i Server Hardware Installation 95 C h a p t e r 6 Installing the 201i server in the Succession 1000 system In this chapter Succession 1000 description 96 Removing the Media Gateway or Media Gateway Expansion cover 104 Installing the 201i server 107 Installing the NTRH3502 SCSI cable for Successio...
Installing the 201i server in the Succession 1000 system Standard 1.07 96 CallPilot Succession 1000 description Introduction The Succession 1000 system is an IP PBX that provides telephony and data capabilities over an IP network. The Succession 1000 system consists of the following major components...
November 2006 Installing the 201i server in the Succession 1000 system 201i Server Hardware Installation 97 one AC power cord connector and On/Off switch The following diagram shows the Call Server: Media Gateway and Media Gateway Expansion The Media Gateway and Media Gateway Expansion provide the...
Installing the 201i server in the Succession 1000 system Standard 1.07 100 CallPilot Back panel connectors The following table describes the connectors that are located on the back of each Media Gateway and Media Gateway Expansion, and how they relate to CallPilot: Media Gateway Expansion Media Gate...
Installing the 201i server in the Succession 1000 system Standard 1.07 102 CallPilot Note: Except for the back panel connectors, the Media Gateway Expansion is similar in external appearance to the Media Gateway. Succession 1000 software For the 201i server, the Succession 1000 system must be runnin...
November 2006 Installing the 201i server in the Succession 1000 system 201i Server Hardware Installation 103 Succession 1000 documentation If you need to refer to the following Succession 1000 technical documents, they are stored on the Customer Documentation Library CD-ROM (NTLH80BA), provided with...
Installing the 201i server in the Succession 1000 system Standard 1.07 106 CallPilot 2 Remove the inside front cover plate as follows: a. Use a screwdriver to loosen each screw on the top of the inside front cover plate by three turns. b. Apply pressure and slide the inside front cover plate upward ...
November 2006 Installing the 201i server in the Succession 1000 system 201i Server Hardware Installation 107 Installing the 201i server Introduction This section describes how to install the 201i server inside the Media Gateway or Media Gateway Expansion. Before you begin Determine which pair of con...
November 2006 Installing the 201i server in the Succession 1000 system 201i Server Hardware Installation 111 Note: Alternate connection scenarios are supported, but are not depicted in this guide. If you want to use a connection scenario that is not described in this guide, ensure that you use appro...
Installing the 201i server in the Succession 1000 system Standard 1.07 114 CallPilot Replacing the Media Gateway or Media Gateway Expansion cover Introduction This section describes how to replace the front bezel and inside front cover plate on the Media Gateway or Media Gateway Expansion. To replac...
Installing the 201i server in the Succession 1000 system Standard 1.07 116 CallPilot To replace the front bezel 1 Align the two posts and the locking tab on the rear of the front bezel with the slots on the inside front cover plate. 2 Push the bezel toward the Media Gateway or Media Gateway Expansio...
November 2006 Installing the 201i server in the Succession 1000 system 201i Server Hardware Installation 117 Connecting cables to the Succession 1000 system Introduction The following items are connected to the back of the Media Gateway or Media Gateway Expansion: multi I/O cable (NTRH0912) This c...
201i Server Hardware Installation 121 C h a p t e r 7 Preparing peripheral devices In this chapter Overview 122 Setting the modem DIP switches 124 Setting the CD-ROM drive SCSI ID and DIP switches 126 Setting the tape drive SCSI ID 12 8 Setting SCSI device termination 130
Preparing peripheral devices Standard 1.07 122 CallPilot Overview Introduction You can connect a modem and one or more SCSI devices to the 201i server. The modem is connected to the 201i server by the multi I/O cable. The SCSI devices are connected to the 201i server by the intermediate SCSI cable. ...
November 2006 Preparing peripheral devices 201i Server Hardware Installation 123 tape drive (NTRH9038): Tandberg SLR5 tape drive Note: This is currently the only supported tape drive. DIP switches, SCSI ID, and SCSI device termination settings For correct operation with the 201i server, you must s...
Preparing peripheral devices Standard 1.07 124 CallPilot Setting the modem DIP switches Introduction Set the modem DIP switches to their default settings. This section describes how to set the modem DIP switches if they have been changed from the default settings. To set the modem DIP switches Ensur...
Preparing peripheral devices Standard 1.07 126 CallPilot Setting the CD-ROM drive SCSI ID and DIP switches Introduction This section describes how to set the CD-ROM drive SCSI ID and DIP switches. Note: The CD-ROM drive discussed in this section is the external SCSI CD-ROM drive (NTRH9105). To set t...
November 2006 Preparing peripheral devices 201i Server Hardware Installation 127 To set the CD-ROM drive DIP switches Set the CD-ROM drive DIP switches as described in the following table: What’s next? If you are also installing a tape drive, set the tape drive SCSI ID (see page 128); otherwise, set...
Preparing peripheral devices Standard 1.07 12 8 CallPilot Setting the tape drive SCSI ID Introduction This section describes how to set the tape drive SCSI ID. Note: The tape drive discussed in this section is the Tandberg SLR5 tape drive (NTRH9038). This is currently the only supported tape drive. ...
Preparing peripheral devices Standard 1.07 130 CallPilot Setting SCSI device termination Introduction If you want to connect SCSI devices in a daisy chain, the last device in the daisy chain must be terminated. This section describes how to terminate the SCSI devices. Supported daisy chain connectio...
Preparing peripheral devices Standard 1.07 132 CallPilot Option 11C, Option 11C Mini For more information about the cabling requirements, see one of the following: “Installing the intermediate SCSI cable for Option 11C” on page 78 “Installing the NTRH3502 SCSI cable for Option 11C Mini” on page ...
November 2006 Preparing peripheral devices 201i Server Hardware Installation 133 Succession 1000 For more information about the cabling requirements, see “Installing the NTRH3502 SCSI cable for Succession 1000” on page 110. To set device termination Terminate the SCSI devices as described in the fol...
Preparing peripheral devices Standard 1.07 134 CallPilot What’s next? Complete the 201i server installation in the switch. See Chapter 8, “Connecting peripheral devices to the 201i server.” a tape drive only do nothing. External termination is not required because the drive is already internally ter...
201i Server Hardware Installation 135 C h a p t e r 8 Connecting peripheral devices to the 201i server In this chapter Overview 136 Installing the MPCs 140 Installing the monitor, keyboard, and mouse 142 Connecting the CD-ROM and tape drives 144 Connecting the 201i server to the switch, ELAN, and CL...
Connecting peripheral devices to the 201i server Standard 1.07 136 CallPilot Overview Introduction This section describes installing the 201i server in the switch, connecting peripheral devices, and starting the 201i server. Connecting the 201i server to the network The switch, ELAN, CLAN, and modem...
Connecting peripheral devices to the 201i server Standard 1.07 13 8 CallPilot 201i server faceplate and peripheral device connectors The following diagram identifies the peripheral device connectors and slots on the 201i server faceplate: G101444 Keyboard connector Mouse connector Monitor connector ...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 139 Starting the 201i server When you lock the 201i into position against the switch backplane, the server starts automatically. You can observe the startup process on both the monitor and the 201i serve...
Connecting peripheral devices to the 201i server Standard 1.07 140 CallPilot Installing the MPCs Introduction Two MPCs are preinstalled at the factory. This section describes how to install additional cards, if required. Correct card insertion The MPC-8 card is keyed so that it fits only one way int...
Connecting peripheral devices to the 201i server Standard 1.07 142 CallPilot Installing the monitor, keyboard, and mouse Introduction You must connect the monitor, keyboard, and mouse to the 201i server so that you can: observe the 201i server startup process. run the Configuration Wizard. per...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 143 PS/2 extension cable The following diagram shows the PS/2 extension cable connected between the 201i server and the USB mouse with USB-to-PS/2 converter. To connect the monitor, keyboard, and mouse 1...
Connecting peripheral devices to the 201i server Standard 1.07 144 CallPilot Connecting the CD-ROM and tape drives Introduction You can connect the CD-ROM, tape drive, or both to the intermediate SCSI cable that you installed earlier. Before you begin Before you can connect the CD-ROM or tape drive,...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 145 Selecting the procedure for your switch To connect the CD-ROM and tape drives to the 201i server (Meridian 1) Note: If you are connecting the SCSI devices to the Option 11C, go to page 147. If you ar...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 147 that is not described in this guide, ensure that you use appropriate cabling for each SCSI device. 5 Connect the power cord for each device. 6 Power up the devices. 7 Continue with “ W hat’s next?” o...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 153 Connecting the 201i server to the switch, ELAN, and CLAN Introduction The CLAN and ELAN connections are established by using the 201i server multi I/O cable. To establish the switch and network conne...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 155 Option 11C Mini or Succession 1000 to a screw on the back of the cabinet 3 Connect the connector on the multi I/O cable that is labeled as ELAN to the switch network hub. 4 If CLAN is required, con...
Connecting peripheral devices to the 201i server Standard 1.07 156 CallPilot Connecting the modem Introduction You must connect the modem to the 201i server if: you want to administer the 201i server from a remote location. you need assistance from Nortel technical support. Required equipment To...
Connecting peripheral devices to the 201i server Standard 1.07 15 8 CallPilot 6 Power on the modem. Note: Ensure that the modem is receiving power by checking that at least one LED on its front panel is lit. 7 Place the modem in an area where it cannot be accidentally damaged or where people cannot ...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 159 Completing the installation Introduction To complete the installation of the 201i server, lock the 201i into position. The server starts up automatically. To complete the installation and start the 2...
November 2006 Connecting peripheral devices to the 201i server 201i Server Hardware Installation 161 6 Ensure that the operating system logon window appears on the monitor. If the logon window does not appear, refer to the CallPilot <server model> Server Maintenance and Diagnostics guide for y...
201i Server Hardware Installation 163 A p p e n d i x A RoHS part conversion table In this appendix RoHS part conversion table 164
RoHS part conversion table Standard 1.07 164 CallPilot RoHS part conversion table This appendix provides a mapping of RoHS-compliant parts to the equivalent non-RoHS-compliant parts for the 201i server. Nortel is phasing in RoHS-compliant 201i servers in countries affected by the EUED (European Unio...
November 2006 RoHS part conversion table 201i Server Hardware Installation 165 T a ble 1: RoHS part con v ersion table Ty p e RoHS par t de scription (Th e non-Ro HS pa rt de scri ption i s in clu ded bel ow in p a rentheses if it is different from the Ro HS pa rt d e scription ) RoHS P E C Code Non...
201i Server Hardware Installation 169 Index Numerics 201i server components, diagram 18 damaged, what to do 42 faceplate connections 31 description 20 diagram 19 , 138 inspecting 42 installation checklist 37 – 40 prerequisites 44 installing large Meridian 1 systems 56 Option 11C 72 Option 11C Mini 7...
Nortel Manuals
-
Nortel ELO ES24
Manual
- Nortel S5100 Manual
-
Nortel BSG12aw
Manual
-
Nortel 2332
Manual
-
Nortel M 901
Manual
- Nortel M3310 Manual
-
Nortel NN43001-307
Manual
-
Nortel 60-12T
Manual
-
Nortel 5580
Manual
-
Nortel NN43113-106
Manual
-
Nortel 3456
Manual
-
Nortel 1100 Series
Manual
-
Nortel 10396EA
Manual
-
Nortel 3395A
Manual
-
Nortel IP 560
Manual
-
Nortel BSR252
Manual
-
Nortel 5399
Manual
- Nortel S1100PJ Manual
-
Nortel P0941753 02
Manual
-
Nortel 8000
Manual