Page 2 - TABLE of CONTENTS; WARNING
W415-0372 / 02.12.03 2 Impr Impr Impr Impr Improper installa oper installa oper installa oper installa oper installation, adjustment, alter tion, adjustment, alter tion, adjustment, alter tion, adjustment, alter tion, adjustment, altera aa a ation, ser tion, ser tion, ser tion, ser tion, service vic...
Page 4 - GENERAL INFORMATION
W415-0372 / 02.12.03 4 This appliance shall be used ONLY outdoors in a well- ventilated space and shall NOT be used inside a building, garage, or any other enclosed area. This appliance MUST NOT be used for cooking. THIS UNIT IS NOT FOR USE WITH SOLID FUEL. Cylinders must be stored outdoors in a wel...
Page 5 - INPUT; GAS INLET PRESSURES; DIMENSIONS; SPECIFICATIONS
W415-0372 / 02.12.03 5 Inches m m Floor 0 0 Side Walls 2 4 610 Top of unit to ceiling 7 2 1830 Natural LP (Propane) Minimum Inlet Pressure 4.5" w.c. 11.0" w.c. Maximum Inlet Pressure 14.0"w.c 14.0"w.c. Model Fuel Max. Input Btu/Hr GPFN Natural Gas 60,000 GPFP Propane Gas 60,000 INPUT...
Page 6 - INSTALLATION; NATURAL GAS
W415-0372 / 02.12.03 6 INSTALLATION The log set and the burner assembly are shipped together.Remove the gas log set and burner assembly and checkfor damage. DO NOT install damaged components. Thelogs are fragile use care when handling.Place the Patioflame on a level/secure surface in desiredlocation...
Page 8 - OPERATION
W415-0372 / 02.12.03 8 • Do not try to light any appliance.• Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire de- part...
Page 9 - MAINTENANCE
W415-0372 / 02.12.03 9 1. The appliance should be inspected before initial use and inspected and cleaned at least annually by a qualifiedfield service person. 2. Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty, must be replacedwith an approved component. 3. ...
Page 10 - REPLACEMENT PARTS; REPLACEMENTS
W415-0372 / 02.12.03 10 1 W035-0104 OUTER BASE 2 W655-0176 LOG SUPPORT 3 W010-1030 BURNER ASSEMBLY 8 W080-0618 ORIFICE BRACKET 9 W455-0076 PROPANE ORIFICE - #43 9 W455-0077 NATURAL GAS ORIFICE - #25 1 0 GL-640 LOG SET 11 W135-0189 BASE LOG 1 2 W135-0190 LOG #1 1 3 W135-0191 LOG #2 1 4 W135-0192 LOG ...
Page 12 - Wolf Steel Appliance Service History
W415-0372 / 02.12.03 12 Wolf Steel Appliance Service History This appliance must be serviced annually depending on usage. Date Service Technician Name Service Performed Special Concerns Dealer Name