Page 3 - Contents
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Appliance dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESEINSTRUCTIONS Keep these operating instructions ina safe place and pass them on to anyfuture user. Read these Instructions carefullybefore installing or using theVentilation System. ~ This appliance is intended for residential use only. Use the applianceonly for its intended purpos...
Page 6 - Functional description
The external blower should only beused in combination with Mieleventilation systems DA 6480 orDA 6490. It must be mounted outside the kitchenon an external wall or on the roof. The external blower is connected to theventilation system by an exhaust ductand power cord. It is operated bymeans of the v...
Page 7 - Appliance dimensions
a Exhaust air connection b Power cord feed-through (strain relief) Appliance dimensions 7
Page 8 - Installation
Example: Installation on an external wall Example: Installation on a roof The exhaust connection can be connected to either the front or back of thedowndraft. For more information see the installation diagram for the downdraft. Installation 8 dai2749
Page 11 - Air extraction
, WARNING Danger of toxic fumes. Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and toproperly exhaust air, the exhaustgases extracted by the hoodshould be vented outside of thebuilding only. Do not vent exhaust air intospaces within w...
Page 12 - WARNING; Electrical connection
, WARNING TO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING: All electrical work should beperformed by a qualified electricianin strict accordance with nationalregulations (for USA: ANSI-NFPA 70)and local safety regulations.Installation, repairs and other workby un...
Page 13 - Important
Important The ventilation system must be hardwired as follows: Black wire: . . . . . . . connect to L1 (live)White wire: . . . . . connect to N (neutral)Green-yellow wire: . . . connect to GND . . . . . . . . . . . . . . . . . . . . . . . . . (ground) ^ The remote blower must beconnected to the vent...
Page 14 - Repairs; After Sales Service
Repairs In the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department. ^ When contacting the TechnicalService Department, please have themodel and serial number of yourappliance available. These can be found on the data platelocated on the housing ...
Page 15 - Disposal of packing material; DANGER; Disposal of an old appliance; Caring for the environment
Disposal of packing material The cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable and recyclable.Please recycle. , DANGER Ensure that any plastic wrappings,bags, etc., are disposed of safelyand kept out of the reach of babiesand youn...