Page 2 - Copyright
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of thiswork may be reproduced, transmitted, or stored in any form or by any meanswithout prior written consent, except by reviewer, who may quote brief pas-sages in a review, or provided for in the Copyright Act of 1976. P...
Page 3 - Table of Contents
ii Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Scanner Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - Introduction; laser bar code projection scanner is encased in; Unpacking List; The shipping carton, should contain the following:
1 Introduction Metrologic's TECH 7 ® laser bar code projection scanner is encased in an NEMA-12 steel case. The case construction enables the scannerto operate in harsh surroundings, especially industrial environments.Water-resistant, shock-resistant, and rugged, the TECH 7 is also fast,aggressive a...
Page 6 - Scanner Installation; To avoid potential prob-
Scanner Installation To maintain compliance with applicable standards, all circuits con-nected to the scanner must meet the requirements for SELV (SafetyExtra Low Voltage) according to EN 60950. To avoid potential prob- lems, do not power up the scanner until the communication cableis secured to the...
Page 7 - Configuration to the Host System
Configuration to the Host System The scanner is shipped from the factory programmed to a set ofdefault conditions noted in the ScanSelect™ Scanner ProgrammingGuide by an asterisk that appears before the brief definition locatednext to the bar code. In order for the scanner to communicate with a host...
Page 8 - Stand Installation; Drill two holes into the work
Stand Installation With the Metrologic stand (Part #45475), the scanner can be posi-tioned in one of two directions. The two orientation choices are verticalor horizontal. (Refer to Figure 1) To install this stand, use the four 6-32 x ½ inch machine screws andtwo #10 pan head wood screws. 1. Drill t...
Page 9 - Back Plate Installation; horizontal mount
Back Plate Installation With the Metrologic back plate (Part #45473), position the scannerin one of two directions. The twoorientation choices are vertical or horizontal. (Refer to Figure 4). To use this stand, use the four 6-32 x ½ inch machine screws and four wood screws to attach the unit to the ...
Page 10 - Parts of Scanner; Green and; This aperture emits the laser light.; spec Connector
Parts of Scanner 1 Green and Red LEDs When the green LED is on, this indicates that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communication to the host is complete. 2 Speaker The speaker e...
Page 11 - Visual Indicators; This indicates the scanner is in program mode.
7 Visual Indicators There is a red and green LED at the top of the scanner. When thescanner is on, the flashing or stationary activity of the LEDs indicatesthe status of the scan and scanner. Steady Green When the laser is on, the green LED is also on. Thisoccurs when an object is in the scan field....
Page 12 - Signaux Optiques; Indique que le scanner se trouve en mode de programmation.
Signaux Optiques Sur la partie supérieure du scanner se trouvent une diode LED rougeet une diode LED verte. Quand le scanner est sous tension, lesdiodes rouge et verte clignotantes ou allumées vous informent surl'état du scanner. Ni la diode rouge, ni la diode verte n'est allumée Il existe deux rais...
Page 13 - Optische Anzeigen; Zeigt an, daß sich der Scanner im Programmiermodus befindet.
Optische Anzeigen Auf dem Scanner befinden sich eine rote und eine grüne Leuchtdiode. Beieingeschaltetem Scanner geben Ihnen die blinkenden bzw. feststehendenLeuchtdiodenanzeigen Aufschluß über den Abtast-und Scannerstatus. Weder rote noch grüne Leuchtdiodenanzeige Es gibt zwei mögliche Gründe, wesh...
Page 14 - Segnali Ottici; Ciò indica che lo scanner si trova nella modalità ScanSet.
Segnali Ottici Sullo scanner si trovano due diodi luminosi: uno rosso e uno verde.Quando lo scanner è inserito, i diodi luminosi, che possono o essereaccesi in continuazione o lampeggiare, Vi informano sullo stato dellascansione e dell'apparecchio. Né il diodo luminoso rosso né quello verde sono acc...
Page 15 - Labels
11 Labels There is one label located inside the window of the scanner notingthat this device is a CDRH Class IIa laser product and IEC 825LASERKLASSE 1. Also, on the scanner is a label located on the backof the unit. This label contains information such as the model number,date of manufacture, seria...
Page 16 - Depth of Scan Field for the MS770 Scanner
Depth of Scan Field for the MS770 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”)from the laser output window. Pass the symbol through the scan areain order for the scanner to recognize the bar code. (Refer to Figure 7) Figure 7: MS770 Scanner, Front View 12 76 mm [3.00 ...
Page 17 - Depth of Scan Field for the MS775 Scanner
Depth of Scan Field for the MS775 Scanner The depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”)from the laser output window. Pass the symbol through the scan areain order for the scanner to recognize the bar code. (Refer to Figure 8) Figure 8: MS775 Scanner, Front View 13 229 mm [9.00...
Page 18 - Maintenance; Spray glass cleaner onto lint free, nonabrasive cleaning cloth.; Applications and Protocols; Version Identifier
Maintenance Smudges and dirt can interfere with the proper scanning of a barcode. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, nonabrasive cleaning cloth. 2. Gently wipe the output window. Applications and Protocols The model number on each scann...
Page 19 - Appendix A; Specifications; Mechanical
Appendix A Specifications Application: Industrial Projection Scanner Light Source: Visible Laser Diode 650 ± 5 nm or 670 ± 5 nm CDRH: CLASS IIa laser product Certifications: CE, UL listed for the US and CUL for Canada EMC: EN 60825: Class 1 EMI: FCC, ICES-003 & EN 55022 Class A Mechanical Dimens...
Page 21 - Appendix B; Pin Assignments; Pin
17 Appendix B Pin Assignments Version "1" Pin Assignments for RS-232, OCIA, and Bi-direc-tional RS-232 Each TECH 7 scanner has a 19-pin male Mil spec connector that islocated on the side of the unit. To connect the scanner to the hostdevice, use a communication cable with a female Mil spec c...
Page 23 - Appendix C; Warranty and Disclaimer; Limited Warranty
Appendix C Warranty and Disclaimer Limited Warranty The Tech 7 scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The Tech 7 scanners have a two (2) year limited warranty from the dateof manufacture. Metrologic warrants and represents that all Tech 7 scanners are f...
Page 24 - Appendix D; Notices
Appendix D Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuantto Part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference when the equipment is operated in a commercial environment. This...
Page 26 - Appendix E; Patents; “Patent Information
Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of thefollowing U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120;4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717;4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538...
Page 27 - Index
A AC 2Applications 1, 14, 15ASIC 1Atrium option 6Autodiscriminate 1, 16 B Back Plate 1, 5, 15Bidirectional RS-232 14, 17 C Cable 2, 6, 17, 18 communication 1, 6scanner link 2 Caution 2, 21Compliance 2, 11, 15Configure 3Connector 2, 6 mil spec 2, 6, 17, 18 Current 15Customer Service iii, 1, 19 D DC 1...
Page 32 - Printed in the USA