Page 3 - ii; ABLE; Introduction
ii T ABLE O F C ONTENTS Introduction How does the MX009 USB Cable Operate?...................................................... 1 What is the difference between USB Keyboard Emulation and USB Serial Emulation? ...................................................................................... 1 ...
Page 5 - NTRODUCTION; USB; For Windows 2000/XP Operating Systems; Refer to pages 8 - 18
1 I NTRODUCTION Metrologic’s MX009 USB Cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Serial communication protocol. The MX009 can be used with all Metrologic products equipped with an RS232 interface, as well as all versions of Metrologic PowerLink compati...
Page 6 - OW IS THE; KEYBOARD; For Non-PowerLink Scanners; prefixes are used to set the; Data
2 I NTRODUCTION • H OW IS THE MX009 CONFIGURED FOR USB KEYBOARD E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol. The default (RS232) settings of the scanner are as fo...
Page 7 - ERIAL; When using USB Serial, special prefixes are not required.
3 I NTRODUCTION (C ONT .) • H OW IS THE MX009 CONFIGURED FOR USB S ERIAL E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol. The default (RS232) settings of the scanner ...
Page 9 - ARTS AND; xx
5 MX009 P ART N UMBER D ESIGNATION AND A CCESSORIES P ARTS AND A CCESSORIES Part No. Description MX009 USB Converter Cable MX009-2 xx 7 x USB Keyboard Emulation Cable MX009-2 xx 8 x USB Serial Emulation Cable P ART N UMBER D ESIGNATION Application Dependent AC to DC Power Transformer (Optional) 00-0...
Page 11 - ABELS; Illustrations shown are not actual size.
7 L ABELS Each MX009 has CE, UL and caution information embedded in the back of the case. The following is an example of embedded information. Figure 1. Each MX009 will also have a flag tag attached to the cable with the date of manufacture, model number, and serial number. Figure 2. ** Illustration...
Page 12 - ONFIGURING FOR; EYBOARD; XX; PowerLink Compatible Scanners; These Metrologic Scanners, used with the MX009 Cable; must; be reconfigured
8 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) PowerLink Compatible Scanners These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS9500 Voyager ® Series • MS6220 Pulsar ...
Page 13 - USA; Continued on next page.
9 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 4. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required ( defaults to USA ). USA ³ 4 1 6 2 6 0 S WITZERLAND ³ 4 1 6 2 8 0 S PAIN ³ 4 1 6 2 5 0 I TALY ³ 4 1 6 2 4 0 G ERMANY ³ 4 1 6 2 3 0 F RAN...
Page 14 - IBM
10 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) U NITED K INGDOM ³ 4 1 6 2 1 0 B ELGIUM ³ 4 1 6 2 0 0 J APANESE ³ 4 1 6 2 1 0 0 IBM 4700 F INANCIAL K EYBOARD ³ 4 1 6 2 7 0 S WEDEN /F INLAND ³ 4 1 6 2 9 0 5. E NTER /E XIT C ONFIGURATION M ODE ³ 9 9 9 9 9 9
Page 15 - Recall Defaults
11 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) MS6720, MS860, AND T ECH S ERIES These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS6720 • MS860 • Tech Series Note: C...
Page 17 - one; of the following bar codes to set Keyboard Emulation.
13 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 9. Scan one of the following bar codes to set Keyboard Emulation. B ELGIUM 0 1 2 3 4 5 0 0 0 6 5 2 U NITED K INGDOM 0 1 2 3 4 5 0 0 0 6 6 9 F RENCH 0 1 2 3 4 5 0 0 0 6 7 6 G ERMAN 0 1 2 3 4 5 0 0 0 6 8 3 I TALIAN 0 1 2 3 4 5 0 0 0 6 9 0 ...
Page 23 - USB Keyboard Emulation
19 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 22. Test Bar Code Scanning the following bar code will transmit the encoded characters followed by the...
Page 24 - 0-pin modular RJ45 Male to USB
20 S PECIFICATIONS MX009 USB C ONVERTER C ABLE S PECIFICATIONS M ECHANICAL Dimensions: 80.4 mm (3.2”) L x 32.4 mm (1.3”) W x 18.7 mm (0.7”) H Weight: 160 g (0.35 lb) Termination: 10-pin modular RJ45 Male to USB 10-pin modular RJ45 Female to USB. 25-pin Female D-Sub to USB Cable: Straight or Coiled E...
Page 27 - OTICES; TESTED TO COMPLY; Notice; Reorient or relocate the receiving antenna; Avertissement
23 N OTICES TESTED TO COMPLY WITH FCC STANDARDS FOR HOME OR OFFICE USE Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, inclu...
Page 28 - METROLOGIC; ATENT; For patent information, please refer to
24 N OTICES D ECLARATION OF C ONFORMITY According to 47 CFR, Part 2 and 15 for Class B Personal Computers and Peripherals; and/or CPU Boards and Power Supplies used with Class B Personal Computers: We: Metrologic Instruments, Inc. Located at: 90 Coles Road Blackwood, NJ 08012 Telephone: 856-228-8100...
Page 29 - Contact a; Alternate Configuration for USB Keyboard Emulation (MX009-2xx7x)
25 A DDITIONAL B AR C ODES Some Metrologic scanners require alternate configuration steps than the steps found on pages 8 - 18. If your scanner was manufactured before May 2002 or does not accept the standard configuration sequences, you may need to use one of the alternate configuration methods lis...
Page 30 - country keyboard required.
26 A DDITIONAL B AR C ODES 7. *Enable LF Suffix ³ 1 1 6 6 1 2 8. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required. B ELGIUM ³ 8 0 3 6 0 6 5 0 U NITED K INGDOM ³ 8 0 3 6 0 6 6 0 F RANCE ³ 8 0 3 6 0 6 7 0 G ERMAN ³ 8 0 3 6 0 6 8 0 I TALIAN ³ 8 0 3 6 0 ...
Page 33 - LF
29 A DDITIONAL B AR C ODES 6. *E NABLE LF S UFFIX ³ 1 1 6 6 1 2 7. E NTER /E XIT C ONFIGURATION M ODE ³ 9 9 9 9 9 9
Page 36 - Printed in the USA