Page 3 - ii; OCATIONS
ii L OCATIONS Corporate Headquarters North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673Email: [email protected]: www.metrologic.com European Headquarters Germany, Metrologic Instruments GmbH...
Page 4 - iii; ABLE OF
iii T ABLE OF C ONTENTS Introduction........................................................................................................... 1Scanner and Accessories ..................................................................................... 2Scanner Connections to the Host ...............
Page 5 - NTRODUCTION
1 I NTRODUCTION Metrologic's MS860 and MS863 laser bar code Scanners are high-speed,aggressive in-counter scanners. Both models have compact, durable housingsfor use with applications where counter top space is limited. The MS860 and MS863 autodiscriminate all standard bar codes. Each modelincludes ...
Page 8 - section of this guide and in the
4 C ONFIGURATION OF THE S CANNER TO THE H OST S YSTEM The MS860/MS863 is shipped from the factory programmed to a set of defaultconditions noted in the Default Settings section of this guide and in the ScanSelect ® Scanner Programming Guide provided. The default settings in the ScanSelect guide have...
Page 9 - OFF; ON
5 C LONING F EATURE The cloning feature is used to program several scanners with the same settings. To clone a scanner: 1. Turn OFF the power to both scanners by unplugging the transformers. 2. Connect the cloning cable ( MLPN 51-51544) between the two scanners. 3. Turn ON the power to both scanners...
Page 10 - : Power to the scanner and 46XX terminal should be turned off before; Note
6 V ERSION 11 IBM 46XX S CANNER Output Format: IBM RS-485 serial input/output for the 4680 and 4690 (46XX) point-of-sale terminals The Version 11 46XX interface can be used in several different ways. Both the46XX terminal and the scanner must be configured to match each other. Warning : Power to the...
Page 11 - Switch 1
7 C ONFIGURING THE MS860-11/MS863-11 S CANNER Located in the Version 11 scanner are two computer boards. One computerboard is for decoding and the other for 46XX IO processing. The decode boardis configured using ScanSet or ScanSelect while the IO board is configured withan internal DIP Switch bank....
Page 12 - ONFIGURING THE
8 C ONFIGURING THE IBM 46XX The 4683 and 4693 terminals are configured on the store controller. The 4684and 4694 terminals are typically configured on the individual terminals. Followthe appropriate guide for your type of equipment. IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Runni...
Page 14 - PC; If the PC is on, exit your application and turn the PC off.; Figure 1
10 C ONNECTION OF A MS860-17 S CANNER TO A PC 1. If the PC is on, exit your application and turn the PC off. 2. Disconnect the keyboard from the PC. Plug the Keyboard Wedge cable to the PC and the keyboard. Use the adapter cable if necessary. 3. Connect the 25-pin D-type connector on the scanner’s h...
Page 16 - Stand; Installation; Figure 3
12 V ERTICAL S TAND K IT Vertical Stand Kit, MLPN 45-45472 includes: a. Vertical Stand [ MLPN 45-45472 ] Qty. 1 b. #6-32 x 3/8” Phillips Head Screw [ MLPN 18-18317 ] Qty. 2 c. #8 x 1.00” Round Head Wood Screw [ MLPN 18-18057 ] Qty. 3 Installation Orientation Note: The arrow on the top of the scanner...
Page 18 - The; OUCH
14 The MS860 T OUCH P LATE The MS860 will enter “standby” when it remains dormant for a time. When thescanner’s computer is on “standby," touching the touch plate will “wake up” thescanner and activate the laser. When the green LED comes on, the scanner ispowering up for full operation. After ap...
Page 20 - Signaux optiques; Indique que le scanner se trouve en mode de programmation.
16 V ISUAL I NDICATORS Signaux optiques Sur la partie supérieure du scanner se trouvent une diode LED rouge et unediode LED verte. Quand le scanner est sous tension, les diodes rouge et verteclignotantes ou allumées vous informent sur l'état du scanner. Ni la diode rouge, ni la diode verte n'est all...
Page 21 - Optische Anzeigen; Zeigt an, daß sich der Scanner im Programmiermodus befindet.
17 V ISUAL I NDICATORS Optische Anzeigen Auf dem Scanner befinden sich eine rote und eine grüne Leuchtdiodenanzeige.Bei eingeschaltetem Scanner geben Ihnen die blinkenden oder feststehendenLeuchtdiodenanzeigen Aufschluß über den Abtast- und Scannerstatus. Weder rote noch grüne Leuchtdiodenanzeige Es...
Page 22 - Segnali ottici; Ciò indica che lo scanner si trova nella modalità ScanSet.
18 V ISUAL I NDICATORS Segnali ottici Sullo scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando loscanner è inserito, i diodi luminosi, che possono o essere accesi in continuazioneo lampeggiare, Vi informano sullo stato della scansione e dell’apparecchio. Né il diodo luminoso rosso ...
Page 23 - temporarily
19 V OLUME S ETTINGS There are four volume settings available: low, medium, high and no volume. Theoperator can temporarily change the volume of the scanner by scanning the bar codes on the volume control card. To change the volume of the scanner permanently , enter program mode and scan the appropr...
Page 25 - ABELS
21 L ABELS There is one label located inside the window of the scanner noting that the deviceis a CDRH Class IIa laser product and IEC 825 LASERKLASSE 1.. Anotherlabel, located on the back of the unit, shows the model number, date ofmanufacture, and serial number. The following are samples of these ...
Page 26 - Figure 6: Depth of Field
22 D EPTH OF F IELD Through the glass at the front of the scanner, safe, low powered laser beams areprojected in a complex pattern that resembles a spider web. Each of the fivescan fields that generate the scan pattern extend to a range of 127mm (5.0"). This range begins from the face of the sca...
Page 28 - mm; Figure 7: Depth of Field and Symbol Specification
24 D EPTH OF F IELD AND S YMBOL S PECIFICATION M INIMUM B AR C ODE E LEMENT W IDTH A B C D E mm .19 .25 .31 .33 .53 mils 7.5 10 12 13 21 Figure 7: Depth of Field and Symbol Specification
Page 29 - AINTENANCE
25 M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.
Page 30 - PECIFICATIONS; AND
26 S PECIFICATIONS MS860 AND MS863 S PECIFICATIONS Application: In-Counter Laser Bar Code Scanner Light Source: VLD 650 ± 10 nm Laser Power 0.525 mW (peak) Laser Class CDRH: CLASS IIa; EN60825-1:1994/A11:1996 Class 1 UL/CSA/TUV: UL Listed, UL 1950; CSA certified, C22.2 No. 950;TUV certified, GS Mark...
Page 32 - OCIA
28 D EFAULT S ETTINGS Many function of the scanner can be “ programmed” - that is, enabled ordisabled. The scanner is shipped from the factory programmed to a set of defaultconditions. The default parameter of the scanner has an asterisk (*) in the chartson the following pages. If an asterisk is not...
Page 39 - IN
35 S CANNER P INOUT C ONNECTIONS Version “1” Pin Assignments for RS-232, OCIA andLight Pen Emulation The version “1” scanner head cable is terminated with a male 25-pin D-typeconnector. Connecting the scanner to the host device may require acommunication cable. The communication cable may include a ...
Page 40 - Version “2” Pin Assignments for Parallel Communication
36 S CANNER P INOUT C ONNECTIONS Version “2” Pin Assignments for Parallel Communication The version “2” scanner head cable is terminated with a male 25-pin D-typeconnector. Connecting the scanner to the host device may require acommunication cable. The communication cable may include a connection fo...
Page 41 - Version “11” Pin Assignments for RS-485
37 S CANNER P INOUT C ONNECTIONS Version “11” Pin Assignments for RS-485 The version “11” scanner head cable is terminated with a male 25-pin D-typeconnector. Connecting the scanner to the host device may require acommunication cable. The communication cable may include a connection for atransformer...
Page 42 - ScanSelect Scanner Programming Guide
38 S CANNER P INOUT C ONNECTIONS Version “17” Pin Assignments for Keyboard Wedge, RS-232 and LightPen Emulation The version “17” scanner head cable is terminated with a male 25-pin D-typeconnector. Connecting the scanner to a PC, requires a communication cable anda transformer. Connecting the commun...
Page 43 - Limited Warranty
39 Limited Warranty The MS860 and MS863 scanners are manufactured by Metrologic at its Blackwood, NewJersey, U.S.A. facility. The MS860 and MS863 scanners have a two (2) year limitedwarranty from the date of manufacture. Metrologic warrants and represents that all MS860and MS863 scanners are free of...
Page 44 - OTICES
40 N OTICES Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfulinterference when the equipment is operated in a commercial environment. This...
Page 47 - NDEX
43 I NDEX A Adapter Cable ............... 1, 6, 10, 38Application ................................... 10 B Bar codes .......................... 1, 19, 27Base .............................................. 8Beeper ........... 3, 4, 7, 10, 15, 18, 27 C Cable ........ 3, 5, 9, 10, 13, 26, 35-38 adapter...
Page 49 - OTES
Page 52 - Printed in the USA