Page 6 - All of the bar codes in this manual require:; see page 2
1 I MPORTANT N OTES - B EFORE Y OU S TART It is important to carefully read the notes marked with a symbol on the pages contained in this manual. Not all configuration codes are designed to be used for both a single and dual cable scanner/scale system. Many of the configuration bar codes require add...
Page 8 - Disconnect; dual cable; Reinstall
3 S CALE P ROGRAM M ODE Figure 3. StratosS Calibration Seal and Switch Location 5. Disconnect the scale-to-host RS232 cable from the unit ( dual cable interface only.) Figure 4. Disconnect scale-to-host RS232 Cable 6. Reinstall the platter and connect AC power to the scanner. Check the AC input requ...
Page 9 - the Scale Operation: Calibration
4 S CALE P ROGRAM M ODE 7. If the system is equipped with a remote scale display, it will read H - - -. 8. Use the vertical window to scan the desired scale configuration bar codes , located on pages 5 - 19. Figure 5. 9. Reconnect the scale-to-host RS232 cable to the scanner (dual cable interface on...
Page 10 - Single or Dual Cable Scale Configuration Bar Codes; Unit Configuration (Pounds or Kilograms; Single or
5 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms ) The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Pound...
Page 11 - Pole Display Configuration; Scale RS485 to Display
6 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale Has Display ³ 9 9 6 0 ...
Page 12 - Scale Settling Filter Configuration; Factory Default Setting
7 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. The scale’s filter ...
Page 14 - Scroll Weight Configuration
9 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scroll Weight Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. These bar codes only affect...
Page 15 - Dual Cable Scale Configuration Bar Codes; Price Computing Configuration; Dual Cable; * Factory Default Setting
10 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are only used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes. * Scale = No Price Computing ³ 9 9 6 0...
Page 16 - Scale Protocols; scale; scanner
11 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program...
Page 19 - after; Scale Protocol; must
14 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be sc...
Page 24 - Set Scale for Single Cable Communication
19 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication The MS2xx0 must be in scale program mode to use this bar code. If your application requires single cable communication, scan the following bar code to set the scale c...
Page 25 - Dual Cable Scanner Configuration Bar Codes; Dual Cable Scanner Mode; No Scale; Dual Cable Scanner OPOS Mode
20 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place, as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale program mode to use the following bar codes. Scanner =...
Page 26 - Various Dual Cable Scanner Mode
21 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Various Dual Cable Scanner Mode The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. REWE ³ 9 9 7 0 1 0 Dual Cable RS232 ...
Page 27 - Generation 46xx and IBM OEM Full Speed USB
22 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes IBM 3 rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM 3 rd Generat...
Page 28 - Single Cable Protocols for POS Compatibility; MSS Global; Single Cable
23 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. MSS Global, English ³ 9 9 9 9 5 1 Scanner/Scale, Sing...
Page 30 - OPOS
25 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility OPOS The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. OPOS, English ³ 9 9 9 9 5 8 Scanner/Scale Single Cable RS23...
Page 33 - IT Retail
28 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IT Retail The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IT Retail, English ³ 9 9 7 0 0 8 Scanner/Scale Single ...
Page 34 - IBM Self Checkout System
29 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM Self Checkout System The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM Self Checkout System, English ³ 9 9...
Page 35 - Various RS232 Single Cable Codes
30 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Various RS232 Single Cable Codes The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. Morrison’s Tec Metric ³ 9 9 7 0...
Page 36 - Generation 46xx
31 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM 3 rd Generation 46xx The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM 3 rd Generation 46xx, English † ³ 9...
Page 37 - IBM OEM Full Speed USB
32 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM OEM Full Speed USB The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM OEM Full Speed USB, English ³ 9 9 9 9...
Page 38 - Additional POS Data Formatting; Full Speed USB Table Top/Handheld; do not
33 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner 4B Handheld ³ 3 1 6 4 3 0 Full Speed USB interface to 4B00h handheld usage. Scanner 4A Flatbed ³ 3 1 6 4 1 0...
Page 40 - Special Function ACK
35 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode. Enable Special Function ACK Answer ³ 1 4 1 7 1 4 Answer simple special functions with ACK. * Disable Special Function ACK ³ 1 4 1...
Page 42 - x-30 Acknowledge Responses
37 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3x-30 Acknowledge Responses The following codes do not require that the MS2xx0 to be in scale program mode. No 3x-30 Answer ³ 1 4 1 7 1 0 This bar code will inhibit all ‘simple acknowledge’ (3x-30) answers to POS or OPOS commands....
Page 43 - Special Function Command Responses
38 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func Ans 3x30 ³ 1 4 1 9 1 4 Answer Special Function commands in the 3x-30 format as opposed to the Ack / Nak w...
Page 47 - BCC in POS communications
42 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting BCC in POS communications The following codes do not require that the MS2xx0 to be in scale program mode. Skip BCC in messages ³ 1 4 1 4 1 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character i...
Page 48 - Scale Status Bytes
43 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3 Scale Status Bytes The following codes do not require that the MS2xx0 to be in scale program mode. Enable 3 Scale Status Bytes ³ 1 2 4 8 1 3 Required for applications where the host system display is the primary scale display an...
Page 49 - Scale Options; No Scale bar
44 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Scale Options The following codes do not require that the MS2xx0 to be in scale program mode. 5-Digit Weight ³ 1 4 1 0 1 0 Sets the English Mode weight to 5-digits, as in xx.yyy pounds. In order to work properly, this bar code mus...
Page 50 - Remote Display; No Remote Display; scanner’s
45 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Remote Display The following codes do not require that the MS2xx0 to be in scale program mode. No Remote Display ³ 1 4 0 9 0 2 When no remote display is installed, scan the No Remote Display bar code AFTER scanning one of the conf...
Page 51 - StratosSTATS
46 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Activate StratosSTATS ³ 9 9 7 0 1 7 This bar code sets: • StratosSTATS bar code data formatting active. • Bar code Attempt Interval to 0....
Page 54 - Additional POS Related Functions; Scanner Beep on Weight Sent
49 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2xx0 to be in scale program mode. Beep on Weight ³ 1 4 1 9 1 7 Request scanner beep when a successful weight is sent. This code should only be used for ‘w...
Page 55 - Restrict In-Store Codes
50 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes ³ 1 2 5 8 1 0 This bar code places tighter restrictions on in-store codes. These codes are: EAN13 Sy...
Page 56 - Scale Shadow Mode
51 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode ³ 1 4 2 2 1 7 This bar code sets the scale to the highest priority to allow for frequent scale - POS commands. T...
Page 58 - Additional Scanner Configuration Bar Codes; Horizontal Depth of Field
53 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. * Horizontal High DOF ³ 2 1 8 7 0 ...
Page 60 - Vertical Depth of Field
55 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. * Vertical High DOF ³ 2 1 8 7 0 0 Th...
Page 62 - Auxiliary Port; Stratos; SCHOOL
57 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Stratos SCHOOL ™ The following codes do not require that the MS2xx0 to be in scale program mode. Auxiliary History Report ³ 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to Stratos SCHOOL ™. The two commands that can be use...
Page 63 - Quick Start for a Secondary Metrologic Scanner; Secondary Scanner
58 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner The following codes do not require that the MS2xx0 to be in scale program mode. S TEP 1 Use the Stratos to scan the following bar code. This bar code will configure the Stratos’ auxiliary port to acc...
Page 64 - Configuration sequence continued from previous page.
59 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequence continued from previous page. Set Stratos Format ³ 4 3 7 5 2 0 Disable Secondary Scanner Beeper ³ 3 1 8 5 0 5 Enable Communication Time Out ³ 1 1 8 4 1 2 Disable CR Suffix ³ 1 ...
Page 65 - EAS Bar Codes; EAS Device Types
60 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. * No EAS Device ³ 3 3 7 2 0 0 No EAS device is connected. * Factory Default Setting EAS Device Type 1 ³ 3 3 7 2 1 0
Page 68 - EAS Timeout
63 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. * EAS = 0 seconds ³ 8 4 6 0 0 0 * Factory Default Setting EAS = 1 second ³ 8 4 6 0 0 1 0 0
Page 73 - EAS Connection
68 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. * EAS Digital Aux Port ³ 1 4 6 1 0 0 The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector. * Factory Default Setting EAS Digital...
Page 76 - Continuous Mode
71 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Continuous Mode The following codes do not require that the MS2xx0 to be in scale program mode. EAS Continuous Mode ³ 1 4 6 1 1 5 When in continuous mode and the scanner is enabled, the EAS will always be online to deactivate an EAS tag. * EAS Int...
Page 77 - EAS Deactivation
72 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Blink Scan LED on Deactivation ³ 1 4 6 1 1 3 The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal. * No Blink LED ...
Page 80 - Sensormatic ScanMax Pro
75 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #3 ³ 9 9 8 0 6 7 For Sensormatic ScanMax Pro, get EAS’s h...
Page 82 - Supplemental Tests; Display Software Numbers; Display; The second and third digits.
77 S CANNER T EST B AR C ODES Supplemental Tests Display Software Numbers The following codes do not require that the MS2xx0 to be in scale program mode. These codes are for test purposes only. The following code will display software #’s on the 2-digit diagnostic display. The lasers will be turned ...
Page 84 - OTES
Page 88 - Printed in the USA