Page 5 - SCHOOL
iv T ABLE OF C ONTENTS Auxiliary Port Stratos SCHOOL ™ ............................................................................... 61 Quick Start for a Secondary Metrologic Scanner ................................. 62 EAS Bar Codes EAS Device Types ..................................................
Page 6 - the Scale Operation: Calibration
1 I MPORTANT N OTES - B EFORE Y OU S TART It is important to read carefully the notes marked with a symbol on the pages contained in this manual. Not all configuration codes are designed to be used for both a single and dual cable scanner/scale system. Many of the configuration bar codes require add...
Page 7 - Important Bar Codes; Scale Save Data
2 I MPORTANT N OTES - B EFORE Y OU S TART Important Bar Codes Scale Save Data Bar Code. The Scale Save Data bar code must be scanned last to “save” the changes in the scale’s memory. The scale will then reset and begin normal operation. This is required only for scale configuration items – not for c...
Page 8 - Single or Dual Cable Scale Configuration Bar Codes; Unit Configuration (Pounds; xx
3 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds ) For Kilogram weight units see page 4. The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable config...
Page 9 - Unit Configuration (Kilograms
4 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Kilograms ) For Pound weight units see page 3. The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable config...
Page 10 - Pole Display Configuration; Scale to Display
5 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporarily disconnect the Scale to Host cab...
Page 12 - Scale Settling Filter Configuration
7 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporarily disconnect the Scale to...
Page 14 - Scale Internal Beeper
9 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Internal Beeper The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporarily disconnect the Scale to Host cable pr...
Page 15 - Zero Cursor
10 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Zero Cursor The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporarily disconnect the Scale to Host cable prior to co...
Page 16 - Quantitative Separator
11 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Quantitative Separator The following bar codes can be used to configure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporarily disconnect the Scale to Host cable ...
Page 17 - Dual Cable Scale Configuration Bar Codes; Scale Protocols; scale
12 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24. If the MS2 xx 0 is currently in a Dual Cable con...
Page 28 - Set Scale for Single Cable Communication; Dual Cable; does not; must
23 S CALE C ONFIGURATION B AR C ODES Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication If the MS2 xx 0 is currently in a Dual Cable configuration, disconnect and remove the Scale to Host cable prior to configuring the scale. The MS2 xx 0 does not need to be in scale...
Page 29 - Dual Cable Scanner Configuration Bar Codes; Dual Cable Scanner Mode; scanner; No Scale; Dual Cable Scanner OPOS Mode
24 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place, as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale service mode to use the following bar codes. Scanner =...
Page 30 - Various Dual Cable Scanner Mode
25 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Various Dual Cable Scanner Mode The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. REWE ³ 9 9 7 0 1 0 Dual Cable RS232 ...
Page 31 - Generation 46xx and IBM OEM Full Speed USB; do not
26 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes IBM 3 rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to configure a Dual Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. IBM 3 rd Gen...
Page 32 - Single Cable Protocols for POS Compatibility; MSS Global; Single Cable
27 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to configure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. MSS Global, English ³ 9 9 9 9 5 1 Scanner/Scale, ...
Page 34 - OPOS
29 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility OPOS The following bar codes can be used to configure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. OPOS, English ³ 9 9 9 9 5 8 Scanner/Scale Single Cable ...
Page 37 - IT Retail
32 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IT Retail The following bar codes can be used to configure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. IT Retail, English ³ 9 9 7 0 0 8 Scanner/Scale Sin...
Page 38 - IBM Self Checkout System
33 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM Self Checkout System The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM Self Checkout System, English ³ 9 9...
Page 39 - Various RS232 Single Cable Codes
34 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Various RS232 Single Cable Codes The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. Morrison’s Tec Metric ³ 9 9 7 0...
Page 40 - Generation 46xx
35 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM 3 rd Generation 46xx The following bar codes can be used to configure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. IBM 3 rd Generation 46xx, English †...
Page 41 - IBM OEM Full Speed USB
36 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM OEM Full Speed USB The following bar codes can be used to configure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode. IBM OEM Full Speed USB, English ³ 9 9...
Page 42 - Additional POS Data Formatting; Full Speed USB Table Top/Handheld
37 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2 xx 0 to be in scale service mode. Scanner 4B Handheld ³ 3 1 6 4 3 0 Full Speed USB interface to 4B00h handheld usage. Scanner 4A Flatbed ³ 3 1 6 4 1...
Page 44 - Special Function ACK
39 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2 xx 0 to be in scale service mode. Enable Special Function ACK Answer ³ 1 4 1 7 1 4 Answer simple special functions with ACK. * Disable Special Function ACK ³ 1 4...
Page 46 - x-30 Acknowledge Responses; inhibit; Factory Default Setting
41 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3x-30 Acknowledge Responses The following codes do not require that the MS2 xx 0 to be in scale service mode. No 3x-30 Answer ³ 1 4 1 7 1 0 This bar code will inhibit all ‘simple acknowledge’ (3x-30) answers to POS or OPOS command...
Page 47 - Special Function Command Responses
42 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2 xx 0 to be in scale service mode. Spec Func Ans 3x30 ³ 1 4 1 9 1 4 Answer Special Function commands in the 3x-30 format as opposed to the Ack / Nak...
Page 51 - BCC in POS communications
46 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting BCC in POS communications The following codes do not require that the MS2 xx 0 to be in scale service mode. Skip BCC in messages ³ 1 4 1 4 1 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character...
Page 52 - Scale Status Bytes
47 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3 Scale Status Bytes The following codes do not require that the MS2 xx 0 to be in scale service mode. Enable 3 Scale Status Bytes ³ 1 2 4 8 1 3 Required for applications where the host system display is the primary scale display ...
Page 53 - Scale Options
48 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Scale Options The following codes do not require that the MS2 xx 0 to be in scale service mode. 5-Digit Weight ³ 1 4 1 0 1 0 Sets the English Mode weight to 5-digits, as in xx.yyy pounds. In order to work properly, this bar code m...
Page 54 - Remote Display; scanner’s
49 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Remote Display The following codes do not require that the MS2 xx 0 to be in scale service mode. No Remote Display ³ 1 4 0 9 0 2 When no remote display is installed, scan the No Remote Display bar code AFTER scanning one of the co...
Page 55 - StratosSTATS
50 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2 xx 0 to be in scale service mode. Activate StratosSTATS ³ 9 9 7 0 1 7 This bar code sets: a. StratosSTATS bar code data formatting active. b. Bar code Attempt Interval t...
Page 56 - * Factory Default Setting
51 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. Dual Stats Xmit ³ 1 3 8 5 1 1 Allows non-RS232 interfaces t...
Page 58 - Additional POS Related Functions; Scanner Beep on Weight Sent
53 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2 xx 0 to be in scale service mode. Beep on Weight ³ 1 4 1 9 1 7 Request scanner beep when a successful weight is sent. This code should only be used for ...
Page 59 - Restrict In-Store Codes
54 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes ³ 1 2 5 8 1 0 This bar code places tighter restrictions on in-store codes. These codes are: EAN13 Sy...
Page 60 - Scale Shadow Mode
55 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode ³ 1 4 2 2 1 7 This bar code sets the scale to the highest priority to allow for frequent scale - POS commands. T...
Page 62 - Additional Scanner Configuration Bar Codes; Horizontal Depth of Field
57 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. * Horizontal High DOF ³ 2 1 8 7 0 ...
Page 64 - Vertical Depth of Field
59 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. * Vertical High DOF ³ 2 1 8 7 0 0 Th...
Page 66 - Auxiliary Port; Stratos
61 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Stratos SCHOOL ™ The following codes do not require that the MS2 xx 0 to be in scale service mode. Auxiliary History Report ³ 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to Stratos SCHOOL ™. The two commands that can be u...
Page 67 - Quick Start for a Secondary Metrologic Scanner; Secondary Scanner
62 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner The following codes do not require that the MS2 xx 0 to be in scale service mode. S TEP 1 Use the Stratos to scan the following bar code. This bar code will configure the Stratos’ auxiliary port to a...
Page 68 - Configuration sequence continued from previous page.
63 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequence continued from previous page. Set Stratos Format ³ 4 3 7 5 2 0 Disable Secondary Scanner Beeper ³ 3 1 8 5 0 5 Enable Communication Time Out ³ 1 1 8 4 1 2 Disable CR Suffix ³ 1 ...
Page 69 - EAS Bar Codes; EAS Device Types
64 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. * No EAS Device ³ 3 3 7 2 0 0 No EAS device is connected. * Factory Default Setting EAS Device Type 1 ³ 3 3 7 2 1 0
Page 72 - EAS Timeout
67 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. * EAS = 0 seconds ³ 8 4 6 0 0 0 * Factory Default Setting EAS = 1 second ³ 8 4 6 0 0 1 0 0
Page 77 - EAS Connection
72 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. * EAS Digital Aux Port ³ 1 4 6 1 0 0 The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector. * Factory Default Setting EAS Digital...
Page 80 - Continuous Mode
75 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Continuous Mode The following codes do not require that the MS2xx0 to be in scale program mode. EAS Continuous Mode ³ 1 4 6 1 1 5 When in continuous mode and the scanner is enabled, the EAS will always be online to deactivate an EAS tag. * EAS Int...
Page 81 - EAS Deactivation
76 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Blink Scan LED on Deactivation ³ 1 4 6 1 1 3 The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal. * No Blink LED ...
Page 84 - Sensormatic ScanMax Pro
79 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #1 ³ 9 9 8 0 6 5 For Sensormatic ScanMax Pro, get EAS’s d...
Page 86 - Supplemental Tests; Display Software Numbers
81 S CANNER T EST B AR C ODES Supplemental Tests Display Software Numbers The following codes do not require that the MS2 xx 0 to be in scale service mode. These codes are for test purposes only. The following code will display software #’s on the 2-digit diagnostic display. The lasers will be turne...
Page 88 - OTES
Page 92 - Printed in the USA