Page 3 - NTRODUCTION; ii
T ABLE OF C ONTENTS I NTRODUCTION Manual Scope .......................................................................................................................................................................... 1 Product Overview ..................................................................
Page 6 - xxx; P T I O N AL; De s c ri p t i o n
I NTRODUCTION B ASE K IT C OMPONENTS B AS E K I T C O M P O N E N T S P a rt # De s c ri p t i o n MS2 2 2 x - 1 0 5 N z Stratos S ™ Series Scanner x 1 Scanner Only, Scale Ready – Compact 2 Scanner Only – Sub-Compact z D Diamonex Horizontal Window S Sapphire Horizontal Window 00-02407 MetroSelect ® ...
Page 7 - E P L AC E M E N T
I NTRODUCTION O PTIONAL A CCESSORIES O P T I O N AL A C C E S S O R I E S P a rt # De s c ri p t i o n AC to DC Power Transformer - Regulated Output: +5.2V @ 2A +12V @ 1A 46-00226 120V United States and Canada 46-00227 220V – 240V Continental European 46-00228 220V – 240V United Kingdom 46-00229 220...
Page 8 - See caution statement on page 3.; Figure 4
I NTRODUCTION G ENERAL P RECAUTIONS The following are some general precautions to remember when handling the Stratos S . Figure 1 D O N OT T URN the unit upside down with the platter in place. D O N OT P RESS on the window in the platter or the vertical window frame. Figure 2 Figure 3 P LATTER R EMO...
Page 9 - For Regulatory Compliance Information refer to pages 54 - 56.; Environmental; Specifications are subject to change without notice.
I NTRODUCTION MS2221 / MS2222 S CANNER D ESIGN S PECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Maximum IR LED Output: 50 μ W per IEC 60825-1 measurement procedure Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code V...
Page 10 - scale ready
B ASE M ODEL C HARACTERISTICS MS2221 Scanner Components Figure 5. MS2221 Components Components I TEM N O . D ESCRIPTION OF I TEM 1 Volume/Tone Multi-Function Button (see page 36) 2 Blue and White LED Indicators (see page 30) 3 Speaker 4 Finger Recesses for Lifting 5 High Impact Window Frame / Vertic...
Page 11 - Dimensions; Please refer to the custom
B ASE M ODEL C HARACTERISTICS MS2221 Scanner Dimensions Figure 6. MS2221 Dimensions Connector Panel Figure 7. MS2221 Connector Panel Scale ready MS2221 models supply additional connectors for scale and display communication cabling. The use of these connections is dependent on the specific manufactu...
Page 12 - Caution and Serial Number Labels
B ASE M ODEL C HARACTERISTICS MS2221 Scanner Caution and Serial Number Labels Figure 8. MS2221 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) a...
Page 16 - Vertical Clearance; SWAP; Power Installation
I NSTALLATION Q UICK I NSTALLATION O UTLINE The following is a quick preview of the steps required for 1 st time installations. Each item is discussed in detail later in this section. • Determine clearance, ventilation and service access requirements. • Determine checkout counter layout taking into ...
Page 21 - Accessories section of this guide for a complete listing.
I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS232 xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual. Figure 19. RS232 Interface ...
Page 22 - USB; Scanner Host USB; xx; Applies only with Stratos
I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) F ULL S PEED USB The following steps describe how to properly install the cables for a Full Speed USB Stratos S application. The scanner must then be configured to match the host’s USB parameters. Cable installation alone does not guarantee ...
Page 23 - MetroSelect Configuration Guide (; See power source caution statement on pages 8 or 11 of this manual.
I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) F ULL S PEED USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation Mode only. 8. Configure the Stratos S for USB Serial Emulation Mode or USB Keyboard Emulation Mode by scanning the appropriate configuration bar codes in the USB ...
Page 24 - XX; must
I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) IBM 46 XX The following steps describe how to properly install the cables for an IBM 46xx Stratos S application. The scanner must then be configured to match the host’s IBM 46xx parameters. Cable installation alone does not guarantee that th...
Page 27 - OCIA
I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) OCIA xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual. Figure 22. OCIA Cable Instal...
Page 28 - Scanner Configuration Bar Codes:; see figure on page 25; Scanner Configuration
I NSTALLATION C ABLE I NSTALLATION (S ECONDARY M ETROLOGIC S CANNER ) The following steps describe how to properly install the cables between a secondary Metrologic scanner and the Stratos S . The Stratos S and the secondary scanner must then be configured to communicate properly. Cable installation...
Page 30 - EAS D; Base Model; EAS In; Figure 25. EAS Deactivation Area
I NSTALLATION EAS D EACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Base Model Checkpoint Recommended Switch Bank Settings MS2221 SW1 & SW2 switches 1 and 6 set to O...
Page 33 - IR A; Specifications are subject to change without notice
S CANNER O PERATION IR A CTIVATION A REA (IR LED O UTPUT ) The Stratos S ’s default power save mode † is Dual Action Power Save Mode #2 (see page 35) . This power save mode † turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minute intervals. Any movement...
Page 34 - ON
S CANNER O PERATION I NDICATOR D ESCRIPTIONS Audible When in operation the Stratos S provides audible feedback that indicates the status of the unit and the current scan. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone) plus three volume settings. To chan...
Page 36 - Diagnostic Indicator Display; Figure 32. Error Code Display (Optional Product Roll Bar Shown); configuration for the proper interface
S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output window near the Metrologic logo on the platter (see figure below). Figure 32. Error Code Display (Optional Product Roll Bar Shown) The following is a list...
Page 39 - MetroSelect Configuration Guide; Blink Power Save Mode:; Laser Off
S CANNER O PERATION P OWER S AVE M ODES The Stratos S has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional information on Power Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF & ON after a configured period of non-use. When the scanner re...
Page 40 - Changing the Beeper Tone; The Multi-Function Button; Figure 34. Changing the Beeper Volume; Changing the Beeper Volume; Laser & Motor Off Power Save Mode; Waking the Unit from All Power Save Modes; Figure 36. Normal Operation
S CANNER O PERATION B EEPER O PTIONS AND B UTTON F UNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new tone will be heard followed by a short pause. Two more new tones will be heard signifying the new setting has been stored in memory....
Page 41 - Default Settings
S CANNER O PERATION S TARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once ( the white LED will remain on for the duration of the beep ). The scanner is now ready to scan. P OWER -U P T EST M ODE When a Stratos S scanner is f...
Page 42 - Figure 37. Platter/Horizontal Scan Window Replacement
M AINTENANCE H ORIZONTAL S CAN W INDOW R EPLACEMENT After the replacement platter has been installed, remove all protective film from the new platter’s window. The unit will not function properly if the protective film is not removed. Figure 37. Platter/Horizontal Scan Window Replacement * See repla...
Page 43 - Figure 38. Vertical Scan Window Replacement
M AINTENANCE V ERTICAL S CAN W INDOW R EPLACEMENT ( MLPN 46-00232) After the replacement vertical window has been installed, remove all protective film from the window. The unit will not function properly if the protective film is not removed. Figure 38. Vertical Scan Window Replacement D AILY M AIN...
Page 51 - Transmit High Priority Code at Timeout
D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB STX Prefix 9 9 TAB Prefix 9 9 Metrologic Prefix 9 9 UPC Prefix 9 9 ETX Suffix 9 9 TAB Suffix 9 9 Carriage Return Suffix * 9 9 Line Feed Suffix * 9 9 UPC Suffix 9 9 Transmit LRC 9 9 Start LRC on 1 st Byte 9 9 S...
Page 53 - Default settings for “; Aux; ” interface; SCHOOL
D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS Default settings for “ Aux ” interface The secondary scanner and the Stratos S series always communicates via RS232. Data is relayed to the host via various primary interfaces P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB Aux Baud Rate 38400 9 9 9 9 Aux P...
Page 55 - reference only; Scale Addendum; Figure 40. Scale Ready Connector Layout; No Connect; Scale to; All signals are referenced from the StratosS scanner.
S CANNER AND C ABLE T ERMINATIONS S CALE R EADY MS2221 M ODELS – A DDITIONAL P INOUT C ONNECTIONS There are four additional 10-pin modular jacks located on the bottom of the of the MS2221 Stratos S models that may be used for an integrated scale application and the use of a remote display. Please ke...
Page 56 - Type A
S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS The following cables are examples of some of the standard cables that may be shipped with the Stratos S scanner. Please keep in mind that every application is unique and the cables received with the Stratos S may be custom cables th...
Page 57 - Pin; 0-Position Angled Modular Plug
S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Aux Port Configuration Cable * , MLPN 57-57008 x -N-3 Pin Function ** 9-Pin D-Type Connector 1 No Connect 2 Output from Scanner 3 Input to Scanner 4 No Connect 5 Ground 6-9 No Connect RS232 LSO/AUX Cable, MLPN 57-57099 x -3 Pin Func...
Page 59 - EMC; Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist:; This Class A digital apparatus complies with Canadian ICES-003.; Remarque; Attention
R EGULATORY C OMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de s...
Page 60 - Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist:
R EGULATORY C OMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes...
Page 61 - ETROLOGIC THE; MTLG A; No.5 Xinghan Street, Xinsu Industrial Square
L IMITED W ARRANTY The MS2200 Stratos S ™ Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS2200 Stratos S Series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS2200 Stratos S...
Page 68 - Printed in the USA