Page 2 - MOBILE HOME INSTALLATION; DIAGRAM “A”; DIAGRAM “B”; DIAGRAM “C”; CONTENTS OF THIS MANUAL; RECOMMENDED LOCATIONS FOR ALARMS

• For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION below. • When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the side wal (see Diagram A). • When mounting th...

Page 3 - BATTERY INSTALLATION; LOCATIONS TO AVOID; WIRING REQUIREMENTS

listed household wire (18 gauge or larger as required by local codes) available at all electrical sup-ply stores and most hardware stores. FIGURE 1 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of A.C. Line White Neutral Side of A.C. Line Red Interconnect Lines (Red ...

Page 4 - OPERATION AND TESTING; Standby Condition; Alarm Memory

4. OPERATION AND TESTING OPERATION: The smoke alarm is operating once A.C. power is applied, fresh batteries are installed andtesting is complete. When the smoke alarm ionization chamber senses products of combustion, thehorn will sound a loud (85db) temporal alarm until the sensing chamber is clear...