Page 2 - Purchaser should post in a prominent location instructions to; WARNING
Improper installation,adjustment, alteration, service or maintenance can cause property damage, injury or death.Read the installation, operating and maintenanceinstructions thoroughly before installing or servicing this equipment. WARNING Improper installationcan cause damage,injury or death. NOT IN...
Page 5 - PLACING MIRACLEAN; Connect incoming gas.
ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND ON CASTERS (THERE IS NO TOP ON THIS STAND) PLACING MIRACLEAN ® GRIDDLE IN OPERATION (When all previous instructions have been completed).Check the serial plate to determine if the burner is setup for the proper type gas before connecting the quick-disconnect o...
Page 6 - COOKING WITH YOUR
4 LIGHTING INSTRUCTIONS MIRACLEAN ® GRIDDLE (See lighting instructions plate attached to front ofMIRACLEAN ® Griddle). Make sure that the main gas valve on the gas supplyline to the Miraclean ® Griddle is in the “ON” position. 1. Turn gas valve knob to "pilot" position. 2. Push gas valve kno...
Page 7 - COOKING PROCEDURES; MIRACLEAN
The Miraclean ® Griddle can be kept in perfect condition by using a razorblade griddle scraper to remove thefilm that is deposited from the productsthat have been previously cooked.Eggs, being cooked at a lowertemperature, require substantially noscraping; but meat and meat productscooked at a highe...
Page 9 - THERMOSTAT CALIBRATION; FRAME
PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily, weekly,monthly and yearly intervals as necessary. Followingpreventive maintenance procedures will help keep yourMIRACLEAN ® Griddle working efficiently. Proper care and servicing will lead to years of quality performance. PREVENT...
Page 10 - PARTS LIST
8 Figure 6-3 Natural and Propane Gas Heating Systems ITEM DESCRIPTION PART NUMBER 1 SPARK IGNITION ASSEMBLYSEE Item 4, Figure 6-2 2 THERMOPILE 022770 3 PILOT TUBE (1/4”) 007998 4 PILOT ASSEMBLY 029769 (ALL NATURAL GAS, 24”-30” 029599 LP, 24”-39” BEF)NATURAL GAS ORIFICE 007696 PROPANE ORIFICE 007766 ...
Page 11 - SERVICE DIAGNOSIS
9 SERVICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use aqualified & licensed service company. (Equipment still under warranty requires it.) NOTE: To correctly and quickly diagnose the system, the chart below shoul...
Page 12 - SERVICE
SERVICE Servicing should only be performed by qualified &licensed service companies. GAS VALVE REGULATOR ADJUSTMENT Recommended gas pressure at manifold (4.0" W.C. Natural gas 10.0" W.C. Propane gas) Adjustment of the gas valve pressure regulator is notnormally necessary since it has bee...
Page 13 - MILLIVOLT CHECK; (FOR QUALIFIED SERVICE TECHNICIANS; ONLY; THERMOSTAT BULB PLACEMENT DETAIL
MILLIVOLT CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONLY ) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the followingoperations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for mi...
Page 14 - D. AUTOMATIC PILOT DROPOUT CHECK; MILLIVOLT CONTROL VALVE; Griddle should be in place at all times. If; TP
B. THERMOPILE OUTPUT CHECK (“B” Reading. Thermostat contacts OPEN - Main burnerOFF.) 1. Thermopile system - 500 millivolts minimum. If the minimum millivolt reading is not obtainable, readjustthermopile for maximum millivolt output. If millivolt readingis still below minimum specified, replace therm...
Page 15 - GAS GRIDDLE WIRING DIAGRAM
13 GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON/OFF SWITCH
Page 16 - ARRANTY
L IMITED W ARRANTY K eating Of Chicago, Inc. ("K eating”) w arrants to the original purchaser . ("Customer"), all ne w K eating Fryers, Filter Systems, Griddles, K eep Krisp®, Custom P asta Systems, T op-Side™ Cook ers, Computer T imers, Fryer & P asta V essels, and K eating replacem...
Page 17 - SERVICE INFORMATION; Have your serial and model number available when ordering parts.; KEATING LIMITED WARRANTY CARD
15 SERVICE INFORMATION If you have a service related question call 1-800-KEATING. Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. 8901 W. 50th Street, McCook, Illinois ...