Keating 2000 - Manual

Keating 2000

Keating 2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 2 – FOR YOUR SAFETY; Purchaser should post in a prominent location instructions to; WARNING
  • Page 3 – IF EQUIPMENT ARRIVES DAMAGED; FIRST STEPS; MINIMUM CLEARANCE; SUITABLE FOR COMBUSTIBLE FLOORS VENTI-
  • Page 4 – GAS CONNECTIONS AND PIPE SIZE; Line pressure must be kept; FLEXIBLE GAS CONNECTORS AND QUICK DIS-; For an appliance equipped with casters:; RESTRAINING DEVICES; ) Adequate means must be provided to limit the; INSTALLATION; ELECTRICAL CONNECTION
  • Page 5 – LEVELING; PLACING KEATING GAS; a. Maximum incoming gas pressure; NEVER move a fryer when full of oil.; FILLING; Before filling the fryer make certain the fryer; LIGHTING INSTRUCTIONS
  • Page 6 – AA MODELS OPERATING INSTRUCTIONS
  • Page 7 – TS MODELS OPERATING INSTRUCTIONS; SHUTDOWN PROCEDURE; COOKING
  • Page 8 – Set thermostat to the desired frying temperature.; SHUTDOWN INSTRUCTIONS; DRAINING; CLEANING AND BOIL-OUT FOR A
  • Page 9 – DO NOT MIX WATER AND HOT OIL; CLEANING AND BOIL-OUT FOR A FRYER WITH; COVERED RECEPTACLE
  • Page 10 – OPERATOR SELF HELP; NOTE; OCCURRENCE
  • Page 11 – PREVENTIVE MAINTENANCE; PREVENTIVE MAINTENANCE CHART; THERMOSTAT CALIBRATION; BEFORE REPLACING, TEST THERMOSTATS; Overshoot; Thermostat Bulb Positioning 10x11, 18 & up Fryer Gas; QUALIFIED SERVICE; PERSONNEL ONLY
  • Page 12 – “KEATING” ELECTRONIC TIMER; Note
  • Page 13 – OPTIONAL TIMER; DIGITAL TIMERS; WARRANTY REPAIRS; ORDERING PARTS; PARTS LIST; CONTROL PANEL AA GAS; Corresponds with parts list on page 12
  • Page 14 – CONTROL PANEL BB GAS; CONTROL PANEL TS GAS
  • Page 18 – BB ELECTRICAL ASSEMBLY WITH SE FILTER
  • Page 22 – KEATING LIMITED WARRANTY CARD; SERVICE INFORMATION; Have your serial and model number available when ordering parts.
Loading the manual

SERIES 2000 FRYER MANUAL

INSTANT RECOVERY

®

GAS FRYER

READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Record the Model No. and Serial of this Instant Recovery® Gas Fryer in the space provided below.

Serial No. __________________________

Model No. __________________________

Keep these numbers for future reference

IMPORTANT

: Keep a copy of your bill of sale. The date on the bill establishes the warranty period should ser-

vice be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating com-
mercial fryers are intended for other than household use.

CONTENTS:

Gas Fryer 2000

08/11

Important Safety Instructions . . . . . . . . . . . . . . .i

INTRODUCTION

. . . . . . . . . . . . . . . . . . . . . . . .1

INSTALLATION

Damage During Shipment . . . . . . . . . . . . . . . . .1

FIRST STEPS

Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirement . . . . . . . . . . . . . . .1
Gas Connectors & Pipe Size . . . . . . . . . . . . . .2
Flexible Gas Connection & Quick Disconnect
Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Restraining Devices . . . . . . . . . . . . . . . . . . . . .2
Electrical Connection . . . . . . . . . . . . . . . . . . . .2
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

PLACING YOUR KEATING FRYER IN OPERA-
TION

Filling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Oil Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . .6
Draining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning and Boil-Out . . . . . . . . . . . . . . . . . .6-8

OPERATOR SELF HELP CHECK LIST

8

PREVENTATIVE MAINTENANCE

Preventive Maintenance Chart . . . . . . . . . . . . .9
Hi-Limit Check Bi-Monthly . . . . . . . . . . . . . . . . .9
Thermostat Calibration . . . . . . . . . . . . . . . . . . .9
Thermostat Bulb Positioning . . . . . . . . . . . . . . .9
Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

WARRANTY REPAIRS

Ordering Parts . . . . . . . . . . . . . . . . . . . . . . . . .11
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . .11-15
Wiring Diagrams . . . . . . . . . . . . . . . . . . . .15-18

1-800-KEATING

w w w. k e a t i n g o f c h i c a g o . c o m

This Owner’s Guide provides specific operating instructions for your model. Use the Instant Recovery®
Fryer only as instructed in this Service Guide.

Versión en español

Si desea obtener usa copia en español de estes Manual del Usario, sirvase escribir la dirección que
se incluye a continuadión.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FOR YOUR SAFETY; Purchaser should post in a prominent location instructions to; WARNING

i Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. FOR YOUR SAFETY Do not store oruse gasoline orother flammablevap...

Page 3 - IF EQUIPMENT ARRIVES DAMAGED; FIRST STEPS; MINIMUM CLEARANCE; SUITABLE FOR COMBUSTIBLE FLOORS VENTI-

INTRODUCTION Instructions in this manual should be read thoroughlybefore attempting to operate this Keating Gas Fryer. Allinstallation and service on Keating equipment must beperformed by qualified, certified, licensed and/or autho-rized installation or service personnel. Operating information for K...

Page 4 - GAS CONNECTIONS AND PIPE SIZE; Line pressure must be kept; FLEXIBLE GAS CONNECTORS AND QUICK DIS-; For an appliance equipped with casters:; RESTRAINING DEVICES; ) Adequate means must be provided to limit the; INSTALLATION; ELECTRICAL CONNECTION

2 only on the type of gas specified by the user and indi-cated on the serial plate located inside the door. Thegas may be natural, propane or manufactured. Thetype of gas cannot be converted to another gas fuel byturning or engaging a switch. GAS CONNECTIONS AND PIPE SIZE A single Keating Gas Fryer ...

Other Keating Models

All Keating Other