Keating LB-65 - Manual
Keating LB-65 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PORTABLE FILTER; OPE RATI NG I NSTR UCTIONS; A. PREPARING THE PORTABLE FILTER
- Page 3 – D. MELTING SOLID SHORTENING; HOT FLU I D. DO NOT FI LL
- Page 4 – SE LF-H E LP G U I DE; PROBLEM
- Page 5 – DISASSEMBLY; SE RVICE
- Page 8 – PARTS LIST
- Page 16 – SERVICE INFORMATION; Have your serial and model number available when ordering parts.
1-800-KEATING
www.keatingofchicago.com
Keep this manual for training new personnel.
p o r t a b l e F i l t e r
0 4 / 1 0
P a r t # 0 1 8 1 6 4
*AS CONTINUOUS PRODUCT IMPROVEMENT OCCURS, SPECIFICATIONS MAY BE CHANGED WITHOUT NOTICE.
Users Manual
PORTABLE FILTER
MODELS PC14, LB-100, LB-65, LB-200
READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE.
IMPORTANT:
Keep a copy of your bill of sale. The date on the bill establishes the warranty period should
service be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating
commercial filters are not intended for household use.
The Owner’s Guide provides specific operating instructions for your model. Use the Portable Filter
only as instructed in this Owner’s Guide.
RECORD THE MODEL AND SERIAL
NUMBERS OF THIS PORTABLE FILTER
IN THE SPACES PROVIDED.
SERIAL NO. ______________________________
MODEL NO. _____________________________
KEEP THESE NUMBERS FOR FUTURE REFERENCE.
OPERATING INSTRUCTIONS
. . . . . . . . . . . . . . . . . . . . . . . .1-2
A: PREPARING THE PORTABLE FILTER . . . . . . . . . . . . . . . . . . . . .1
B: FILTRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
C: CLEAN-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
D: MELTING SOLID SHORTENING . . . . . . . . . . . . . . . . . . . . . . . . .2
E: FILTER FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
WARRANTY REPAIRS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SELF-HELP GUIDE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PREVENTIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
A: MELT/PUMP INDICATOR LIGHTS . . . . . . . . . . . . . . . . . . . . . . . .4
B: MELT/PUMP ON/OFF SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . .4
C: MELT CYCLE SENSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
D: HEATER ELEMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
E: PUMP AND MOTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
F: HEAT TAPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
PARTS LIST
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
ORDERING PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
WARNING AND OPERATING PLATES . . . . . . . . . . . . . . . . . . . . . . .7
WIRING DIAGRAMS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-13
WARRANTY INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . .14
CONTENTS:
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
PORTABLE FILTER OPE RATI NG I NSTR UCTIONS 1 Figure 1.3: Assemble filter Figure 1.1: Remove screen over elements/ tubes Figure 1.2: Stir with spoon to remove water A. PREPARING THE PORTABLE FILTER 1. Remove screen from over tubes/element with tongs or a Drain Clean Out Rod (See Figure 1.1). SCREEN O...
C. CLEAN-UP FILTER UNIT AND PIPES WILL REMAIN HOT FOLLOWINGFILTRATION. ALLOW THE UNIT TO COOL DOWN BEFORE CLEANUP. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY TO THEOPERATOR. 1. Turn off filter and disconnect from electrical source. 2. Remove strainer basket and hold down ring for cleaning 3. Remo...
SE LF-H E LP G U I DE 3 PROBLEM PROBABLE CAUSE SOLUTION (Follow Sequentially) Motor runs but will not pump oil. A. Solidified shortening may have plugged pipes. Turn on fat melter for 20 minutes. This will heatfilter tub and pipes to free system of solidifiedshortening. Reset motor before attempting...