Page 2 - TABLE OF CONTENTS
i TABLE OF CONTENTS SECTION I INTRODUCTION General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Standard Accessories . . . . . . . . . . . . . . . . . . . . . . .1 Cooking Head Specifications . . . . . . ....
Page 3 - FOR YOUR SAFETY; WARNING
NOTICE: This operating, installation, and service manual should be given to the user. The operator of the griddle should be familiar with the functions and operation of the griddle. This manual must be kept in a prominent, easilyreachable location near the griddle. Notice: Keating of Chicago, Inc. (...
Page 4 - I INTRODUCTION; GENERAL; What to do if equipment arrives damaged:; INSTALLATION
1 I INTRODUCTION GENERAL Keating Top-Side TM Cookers are designed to give maximum production efficiency, delivering high qualityfood products. The following design features areincorporated into Keating Top-Side TM Cookers. STANDARDFEATURES Stainless steel control panel Stainless steel head cover MIR...
Page 5 - THIS APPLIANCE MUST BE EARTHED.; III OPERATING; OPERATION OF THE TOP-SIDE; COOKER; COOKING; SHUTDOWN; A. Keating Cooking Sheets
2 ELECTRICALCONNECTION Each Keating Top-Side TM Cooking head is equipped with a 9' (2.74m) neoprene covered, 12 gauge 4mm(2),three wire with ground electrical cord. No plug isprovided. Each cooking head is rated 4000W, 18 amps,single phase at 220 Volts (4.37kW, 19 amps, singlephase at 230 Volts) and...
Page 6 - B. Cooking Sheet Clips; CAUTION; IV MAINTENANCE; WARRANTY REPAIRS
3 WARNING THE COOKING HEAD WILL BE HOT. USE PROPERCARE WHEN CLEANING THE COOKING SHEETS. End of day cleaning: Before the griddle is turned off for the day, the cookingsheets should be cleaned as described below. Wearheat resistant gloves for maximum safety during theentire cleaning procedure. 1. At ...
Page 8 - V SERVICE DIAGNOSIS; Disconnect power before service.
PROBLEM PROBABLE CAUSE SOLUTION POWER ON light does a. No electricity to Top-Side TM a. Connect Top-Side TM Cooker to an not come on. Cooker. approved source of power. b. ON/OFF switch is faulty. b. Replace ON/OFF switch. ELEMENT ON light does a. Connections to thermostat are a. Check connections an...
Page 9 - MOUNTING AND WIRING INSTRUCTIONS; New Thermostat Mounting and Wiring Instructions
6 THERMOSTAT REPLACEMENT KIT (PART #057138) MOUNTING AND WIRING INSTRUCTIONS New Thermostat Mounting and Wiring Instructions 1. After removing the old thermostat, drill four larger holes formounting new housing (See Figure A) . After drilling holes, remove any metal filings from inside the unit. 2. ...
Page 11 - VI EXPLODED VIEW & PARTS LIST; ORDERING PARTS; COOKING HEAD
8 VI EXPLODED VIEW & PARTS LIST ORDERING PARTS Parts may be ordered by part number by calling 1-800-KEATING or your local service company. You may also orderonline at Keating’s part store, www.keatingofchicago.com Refer to the Keating Top-Side™ Cooker Limited Warranty for complete service and or...
Page 12 - COOKING HEAD FOR MANUFACTURED YEARS 4/99 - 2004
9 TOP-SIDE TM COOKING HEAD FOR MANUFACTURED YEARS 4/99 - 2004 Figure 6-1 PART ITEM DESCRIPTION QTY. NUMBER 1 THERMOSTAT TEMPERATURE PROBE KIT 1 016659 2 COOKING HEAD (COMPLETE) 1 1-800-KEATING 3 STOP CLEVIS PIN, S/S 1 015164 4 SWIVEL BRACKET WIRE SLEEVE (INCL. IN ITEM 5) 1 --- 5 SWIVEL BRACKET 1 028...
Page 13 - COOKER CONTROL PANEL
10 To cooking head TOP-SIDE TM COOKER CONTROL PANEL PART ITEM DESCRIPTION QTY. NUMBER 1 THERMOSTAT 1 057138 2 THERMOSTAT KNOB 1 no longer available 3 THERMOSTAT DIAL PLATE 1 no longer available 4 HI-LIMIT CONTROL 1 010311 5 HI-LIMIT MOUNTING BRACKET 1 016654 6 CONTACTOR, 50A, 3-POLE 1 011184 7 ROCKE...
Page 14 - VII WIRING DIAGRAM; COOKER WIRING DIAGRAMS
11 VII WIRING DIAGRAM TOP-SIDE TM COOKER WIRING DIAGRAMS
Page 16 - SERVICE INFORMATION; Have your serial and model number available when ordering parts.; KEATING LIMITED WARRANTY CARD; “Serving Those Who Serve The Very Best”
13 SERVICE INFORMATION If you have a service related question call 1-800-KEATING. Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. 8901 West 50th Street, McCook, Illinoi...