CV-M40 3 Table of Contents CE declaration ............................................................................................................................. 2 1. General ..........................................................................................................................
Page 4 - Standard composition; Optional accessories
4 CV-M40 1. General The CV-M40 is a 1/2” CCD progressive scan camera, incorporating double speed and partial scan techniques, housed in a compact and robust package. Using the latest CCD sensor technology with square pixels provides excellent resolution and signal to noise ratio, together with flexi...
Page 5 - Locations and functions; CAUTION
CV-M40 5 4. Locations and functions 1. CCD sensor 2. Lens mount 3. BNC connector 4. SW1 switch 5. 6 pin multi connector 6. 12 pin multi connector 7. Gain potentiometer 8. Tripod mount plate 9. Screw holes for Tripod mount plate : : : : : : : 1/2 “ IT CCD sensor C-mount type Video output (VS 1.0 Vpp ...
Page 8 - To use this mode, set up the camera as follows ; Functions and operations
8 CV-M40 To output int. HD/VD signal, make jumper JP9/JP11 open-circuited, and JP12/JP13 short-circuited. All jumpers are located on PK8273 board. Please refer to 7-2-3. Jumpers onPK8273 board. b) Output of internal HD/VD signal Int. HD/VD signal is effective only at 75 Ohm termination. 6-2. Ext. tr...
Page 9 - The pulse width of the external trigger pulse must be 2H to 525H.; The pulse width of the external trigger pulse must be 2H to 1300H.
CV-M40 9 Set SW1-5 at ON, and SW1-6 at OFF to select the Edge pre-select mode. Set SW1-1 to SW1-3 to select the appropriate shutter speed. For controlling the shutterspeed by the RS 232C serial interface, set SW1-8 at ON. Set the SW1-4 switch to ON to select the Binning mode and set the switch SW1-7...
Page 13 - Pulse width control mode
CV-M40 13 4. Pulse width control mode Note 1:Sync or HD is not mentioned Note 2:1H=31.777 S Note 3:WEN polarity can be chosen at JP22 of I/F board Waiting for Ext.Trigger Waiting for Ext.Trigger Valid period Valid period Ext.Trig VIDEO OUT WEN(positive) WEN(Negative) Ext.Trig VIDEO OUT WEN(positive)...
Page 15 - Note : The above switches are set at OFF position by factory pre-set.; Noticeable flicker in the picture.; Shutter; OFF ON
CV-M40 1 5 7-1. SW1 switch on the rear panel 7. Mode setting Note : The above switches are set at OFF position by factory pre-set. 7-1-1. Shutter speed (SW1-1, SW1-2, SW1-3) SW1-1, SW1-2 and SW1-3 switches are effective only when the SW1-8 switch is set at OFF position. Exposing the CCD to direct or...
Page 17 - Note : Gamma is set at “Setting by RS 232C interface” with 1.0.
CV-M40 17 7-2. Jumpers on board 7-2-2. Jumpers on PK8202 board Jumpers JP5, JP6 and JP7 enable or disable the ext. trigger input, the WEN output and pixel clock output, respectively. 7-2-1. Jumpers on PK8201 board Jumpers JP1 and JP2 are used to select the gamma setting. See table below for options....
Page 20 - External appearance
Page 21 - Note : Above specifications are subject to change without notice.
CV-M40 21 9. Specification Note : Above specifications are subject to change without notice. Model name CV-M40 Scanning system 525 lines, 60 frames/sec. CCD sensor Monochorme 1/2" IT CCD sensor progressive scan Sensing area for video out 6.4 mm (h) x 4.8 mm (v) Effective pixels 659 (h) x 494 (v)...
Page 23 - EIA; Users Mode Settings
CV-M40 2 3 This manual can be downloaded from: www.jai.com 11. User’s Record Camera type: CV-M40 Scanning system: EIA Revision: (Revision C) Serial No. ................. Users Mode Settings Users Modifications