Intel ® Server Chassis SR1450 User Guide iii Preface About this Manual Thank you for purchasing and using the Intel® Server Chassis SR1450. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server chassis. This document provides a br...
Preface iv Product Contents, Order Options, and Accessories The server chassis SR1450 is compatible with the Intel® Server Board SE7520JR2. Your Server Chassis SR1450 ships with the following items: A box of hardware components, referred to below as the “hardware box” One 520W power supply modul...
Preface vi Additional Information and Software If you need more information about this product or information about the accessories that can be used with this server board, use the following resources. These sources are available at http://support.intel.com/support/motherboards/server/chassis/SR1450...
Preface Intel ® Server Chassis SR1450 User Guide vii Safety Information WARNING Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide t...
Preface viii Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous condi...
Preface Intel ® Server Chassis SR1450 User Guide ix Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information or at http://support.intel.com/support/motherboards/server/sb/CS-0...
Intel ® Server Chassis SR1450 User Guide x Contents Warnings ....................................................................................................... viii 1 Server Chassis Features ............................................................................. 14 Component Identificatio...
Contents xii Extent of Limited Warranty .................................................................................................... 85 Warranty Limitations and Exclusions .................................................................................... 86 Limitations of Liability ..........
Contents Intel ® Server Chassis SR1450 User Guide xiii Figure 41. Removing the Power Supply Air Duct....................................................................... 56 Figure 42. Removing a Power Supply Fan Module ................................................................... 57 Figure 4...
Intel ® Server Chassis SR1450 User Guide 14 1 Server Chassis Features This chapter briefly describes the main features of Intel ® Server Chassis SR1450. This chapter provides drawings of the product, a list of the server features, and diagrams showing the location of important components and connect...
Server Chassis Features Intel® Server Chassis SR1450 User Guide 17 Component Identification Internal Components The diagram below shows the server chassis with a server board installed into it. TP01585 C A L M K J I H D B G E F A. Single system PCI fan H. System fan module B. Power supply fan module...
Server Chassis Features 18 Standard Control Panel The diagram below shows the features available on the Standard Control Panel. The Standard Control Panel is one of two required front panel options that can be selected. The other option is the Intel® Local Control Panel. For instructions on installi...
Server Chassis Features Intel® Server Chassis SR1450 User Guide 19 Intel ® Local Control Panel The diagram below shows the features available on the Intel ® Local Control Panel. The Intel Local Control Panel is one of two required front panel options that can be selected. The other option is the Sta...
Server Chassis Features 20 Callout Feature Function J System Status LED Solid green indicates normal operation. Blinking green indicates degraded performance. Solid amber indicates a critical or non-recoverable condition. Blinking amber indicates a non-critical condition. No light indicates POST is ...
Server Chassis Features Intel® Server Chassis SR1450 User Guide 21 Peripheral Devices (Front Features) The chassis provides locations and hardware for installing hard drives, a floppy drive, CD-ROM drive, or DVD-ROM drive. The drives must be purchased separately. The following figure shows the avail...
Server Chassis Features 22 Floppy / CD-ROM / DVD-ROM Slimline Carriers The slimline drive carriers can be used with one slimline floppy, CD-ROM or DVD-ROM drive. There are two carriers that ship with the chassis; one carrier is for a CD-ROM or DVD-ROM, and the other is for a slimline floppy. Unless ...
Server Chassis Features Intel® Server Chassis SR1450 User Guide 23 Rack-Mounted Systems Your Intel ® Server Chassis SR1450 is designed to be mounted into a rack. You must choose from one of two accessories. The Intel Server Chassis SR1450 comes ready for mounting using the Tool-less Rail Kit (AXXHER...
Intel ® Server Chassis SR1450 User Guide 24 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the safety instructions at the beginning of this manual. See “Safety Information.” This document provides instructions for adding and rep...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 25 Removing and Installing the Chassis Cover Removing the Chassis Cover The Server Chassis SR1450 must be operated with the top cover in place to ensure proper cooling. You will need to remove the top cover to add or replac...
Hardware Installations and Upgrades 26 Installing the Chassis Cover 1. Place the cover over the chassis so that the side edges of the cover sit just inside the chassis sidewalls. 2. Slide the cover forward until it clicks into place. See letter “A” in the figure below. 3. (Optional) Insert the shipp...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 27 Removing and Installing the Front Bezel The front bezels are available as optional accessories for the Server Chassis SR1450. Two front bezel options are available. One is used for the Standard Control Panel and the othe...
Hardware Installations and Upgrades 28 Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the front bezel for the Intel Local Control Panel. The front bezel is optional. 1. At each end of the bezel, line up the center notch on the bezel with the...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 29 Removing the Processor Air Duct 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. ...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 31 Installing and Removing a Hard Disk Drive Up to three hard drives of one of the following types can be installed, depending on the hard drive installation option used in your server chassis and the drives supported by yo...
Hardware Installations and Upgrades 32 4. Remove the four screws that attach the plastic baffle or the previously installed hard drive to the drive carrier. Two screws are at each side of the baffle or the hard drive. If required, store the plastic baffle for future use. TP01600 A B Figure 17. Remov...
Hardware Installations and Upgrades 34 Installing a Floppy Drive into Slimline Bay Use these instructions if you are installing a floppy drive into the slimline drive bay at the upper left side of your chassis. ✏ NOTE The carrier for the slimline floppy drive that is used in these instructions was s...
Hardware Installations and Upgrades 36 13. Connect the floppy drive data cable that was included with your kit between the interposer board and the server board. See letters “B” and “C” in the figure. See your server board documentation for assistance in locating the connector location on the server...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 37 14. Install the chassis cover. For instructions, see “ Installing the Chassis Cover .” 15. (Optional) Install the front bezel. For instructions, see “ Removing and Installing the Front Bezel .” 16. Plug all peripheral de...
Hardware Installations and Upgrades 40 14. Attach the other end of the flat flex cable to the interposer board. 15. Install the interposer board into the floppy drive conversion kit carrier. One screw attaches on the right side. 16. Slide the carrier assembly into center hard drive bay until it clic...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 41 Installing or Removing a CD-ROM or DVD-ROM Drive CAUTION CD-ROM and DVD-ROM drives are NOT hot swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral dev...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 43 Removing a CD-ROM or DVD-ROM Drive from the Slimline Bay 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and t...
Hardware Installations and Upgrades 44 Installing a PCI Riser Card To install the PCI riser card, use the following instructions. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC p...
Hardware Installations and Upgrades 46 Removing a PCI Riser Card The PCI riser card can be replaced if it fails or if a different option is required. To replace the PCI riser card, use the following instructions to remove it, and then follow the instructions under “Installing a PCI Riser Card” to in...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 47 Installing and Removing a PCI Add-in Card Installing a PCI Add-in Card In the slot provided by the PCI riser card, you can install one add-in card. Use the following instructions to install an add-in card. 1. Observe the...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 49 Removing a PCI Add-in Card 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remov...
Hardware Installations and Upgrades 50 Replacing the Standard Control Panel Your server must be operated with a control panel installed. The steps for replacing the Standard Control Panel are listed below. CAUTION The control panel is NOT hot swappable. Before removing or replacing the control panel...
Hardware Installations and Upgrades 54 8. Note the position of the raised arrows in the top of the replacement fan. Position the fan so one arrow points to the left, and the other arrow points to the rear of the chassis. The fan cable should be pointing to the rear of the chassis. 9. With the fan ar...
Hardware Installations and Upgrades 56 Removing the Power Supply Air Duct Use the steps below to remove the power supply air duct. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC ...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 57 Replacing a Power Supply Fan Module The power supply fan modules in the Server Chassis SR1450 can be individually replaced if one of them fails. Use the steps below to replace a dual rotor fan. CAUTION The power supply f...
Hardware Installations and Upgrades 58 Replacing the Power Distribution Board The power distribution board is located between the two power supplies. This board can be replaced if it fails. To replace the power distribution board, use the following instructions. 1. Observe the safety and ESD precaut...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 61 Replacing the Hot-Swap Power Supply The power supply can be replaced if it fails. If your server uses a redundant power supply, you do not need to power down your server to replace the failed power supply, as long as the...
Hardware Installations and Upgrades 62 TP01630 B A Figure 46. Removing the Rear Hot-Swap Power Supply from the Chassis Installing a Hot-Swap Power Supply To install a replacement power supply or to add a redundant power supply, use the following instructions. 1. (Replacing power supply only) Remove ...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 63 Removing and Installing the SATA or SCSI Backplane Your server chassis must be configured with one of the following drive installation options: A hot-swap SCSI option that came with a SCSI backplane board. A hot-swap...
Hardware Installations and Upgrades 64 Removing the SATA or SCSI Backplane 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the chassis cover. For instruc...
Hardware Installations and Upgrades Intel ® Server Chassis SR1450 User Guide 65 Installing the SATA or SCSI Backplane 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all peripheral devices and the AC power cable(s...
Intel ® Server Chassis SR1450 User Guide 67 Technical Reference Cable Routing When you add or remove components from your server chassis, make sure your cables are routed correctly before reinstalling the chassis cover. Use caution to make sure no cables or wires are pinched and that the airflow fro...
Technical Reference Intel ® Server Chassis SR1450 User Guide 69 Power Supply Specifications 520-W Single Power Supply Input Voltages 100-127 V ∼ at 50/60 Hz; 6.7 A max. 200-240 V ∼ at 50/60 Hz; 3.4 A max. 520-W Single Power Supply Output Voltages The table below lists the total wattage available...
Technical Reference 70 System Environmental Specifications Table 5. Environmental Specifications Temperature Non-operating Operating –40 ° to 70 °C. +10 ° C to +35 ° C with the maximum rate of change not to exceed 10 ° C per hour Humidity Non-operating 90% relative humidity (non-condensing) at 35 °C...
Intel ® Server Chassis SR1450 User Guide 71 Equipment Log and Worksheets Equipment Log Use this equipment log to record information about your server. Item Manufacturer Name and Model Number Serial Number Date Installed Chassis Server Board Processor Speed and Cache Memory Video Display Keyboard Mou...
Equipment Log and Worksheets 72 Current Usage Calculating Power Usage The total combined wattage for your configuration must be less than the wattage rating for your power supply. Use the worksheets in this section to calculate the total used by your configuration. See the documentation that came wi...
Equipment Log and Worksheets Intel ® Server Chassis SR1450 User Guide 73 Worksheet, Total Combined Power Used by the Server 1. From the previous worksheet, enter the total current for each column. 2. Multiply the voltage by the total current to get the total wattage for each voltage level. 3. Add th...
Intel ® Server Chassis SR1450 User Guide 74 Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Server Chassis SR1450 complies with the following safety requirements: UL60950 – CSA 60950(USA / Canada) EN60950 (Europe) IEC60950 (International) CB ...
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 75 Certifications / Registrations / Declarations UL Certification (US/Canada) CE Declaration of Conformity (CENELEC Europe) FCC/ICES-003 Class A Attestation (USA/Canada) VCCI Certification (Japan) C-Tick Declara...
Regulatory and Compliance Information 76 Table 8. Product Certification Markings (continued) Regulatory Compliance Country Marking BSMI Certification Number & Class A Warning Taiwan GOST R Marking Russia RRL MIC Mark Korea China Compulsory Certification Mark China Electromagnetic Compatibility N...
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 77 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer...
Regulatory and Compliance Information 78 VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a dome...
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 79 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging ...
Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SR1450 Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone sup...
Intel Server Issue Report Form Intel ® Server Chassis SR1450 User Guide Intel ® Server Issue Report Form Date Submitted: Company Name: Contact Name: Email Address: Intel Server Product: Priority (Critical, Hot, High, Low): Brief Problem Description. Provide a brief description below. See the last pa...
Operating System Information Operating System Version Service Pack # Peripheral Information Check each box below that is used, and provide the requested information Peripheral Card Or Peripheral Description Driver Revision IRQ # I/O Base Address FW Rev# Add-in Cards Add-in Card Add-in Card Add...
Intel Server Issue Report Form Intel ® Server Chassis SR1450 User Guide Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troublesh...
Intel ® Server Chassis SR1450 User Guide 85 Warranty Limited Warranty for Intel ® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel ® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered...
Warranty Warranty Limitations and Exclusions These warranties replace all other warranties, expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel makes no expressed warranties beyond those stated here. Intel disclaim...
Warranty Intel ® Server Chassis SR1450 User Guide 87 How to Obtain Warranty Service To obtain warranty service for this Product, you may contact Intel or your authorized distributor. North America and Latin America To obtain warranty repair for the product, please go to the following Web site to o...
Intel Manuals
-
Intel FSB- 865G
Manual
-
Intel P3700
Manual
-
Intel 100BASE-T4
Manual
-
Intel SRCU31
Manual
-
Intel IXP400
Manual
-
Intel Netstructure MPRTM0020 Rear Transition module
Manual
-
Intel EES-5718
Manual
-
Intel TIGI2U
Manual
-
Intel X18-M
Manual
-
Intel 80287
Manual
-
Intel AR-B1890
Manual
-
Intel PPC-7508F M1
Manual
-
Intel SSDSCKHW360A401
Manual
-
Intel SYS7180VE
Manual
-
Intel 330T
Manual
-
Intel 4
Manual
-
Intel 82555
Manual
-
Intel PRO
Manual
-
Intel CAP15ECS7TB
Manual
-
Intel PCI-7200
Manual