Page 3 - Preface; About this Manual
Preface Preface About this Manual Thank you for purchasing and using the Intel ® Carrier Grade Server TIGI2U (Telecom Industrial Grade Intel ® Xeon™ processor 2U Server). This manual is for system technicians who are responsible for troubleshooting, upgrading, and repairing this Carrier Grade Server...
Page 4 - What Your Platform Includes
Preface What Your Platform Includes Your Intel ® Carrier Grade Server TIGI2U includes the following components: One Intel ® Server Board SE7502JR2 One 2U rack-mount chassis Two hard disk drive carriers One bracket for installing a CD ROM or DVD-ROM drive One 600 W SSI (Server System Infrastructure) ...
Page 5 - Safety Information; WARNING
Preface Additional Information and Software If you need more information about this product or information about the accessories that can be used with this Carrier Grade Server, go to http://support.intel.com/support/motherboards/server/TIGI2U/index.htm In-depth technical information about the serve...
Page 8 - CAUTION
Preface WARNING Do not attempt to modify or use an AC power cordset that is not the exact type required. You must use a power cordset that meets the following criteria: • Rating: In the U.S. and Canada, cords must be UL (Underwriters Laboratories, Inc.) Listed/CSA (Canadian Standards Organization) C...
Page 9 - Safety Cautions; Wichtige Sicherheitshinweise; 重要安全指导; Consignes de sécurité; Instrucciones de seguridad importantes
Preface Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/CS-010770.htm. Wichtige S...
Page 10 - Contents
Contents Contents Preface .................................................................................................................iii Intel ® Carrier Grade Server TIGI2U Features .................................................. 16 Server Platform Components ..................................
Page 13 - Figures
Contents Figures Figure 1. Intel ® Carrier Grade Server TIGI2U ...................................................................... 16 Figure 2. System Components............................................................................................. 19 Figure 3. Platform Back...................
Page 15 - Tables
Contents Tables Table 1. Server Platform Features ................................................................................. 17 Table 2. NIC LEDs.......................................................................................................... 20 Table 3. Configuration Jumper [J1H2] ....
Page 19 - Server Platform Components
Server Platform Features Server Platform Components TP01643 C A I H D G E F B A. Power Distribution Board F. System Fans B. Processor Air Duct G. Front Panel I/O Board C. Power Supplies H. SCSI Hard Disk Drive Carriers D. PCI Riser Card Assembly I. Peripheral Bay (CD-ROM or DVD-ROM drive) E. Intel ®...
Page 20 - Server Platform Back Panel
Server Platform Features Server Platform Back Panel TP01644 A H G F J K L M N I B C D E A DB15 Alarms Connector H RJ45 NIC 1 Connector B PCI Card Bracket (low-profile) I RJ45 NIC 2 Connector C PCI Card Bracket (full-height) J Video Connector D Optional second power supply or filler panel (filler pan...
Page 21 - Server Platform Front Panel
Server Platform Features Server Platform Front Panel 1 0 Alarms Status ID ON NIC CRT MNR PWR MJR TP01645 N O Q R S T U P 1 0 Alarms Status ID ON NIC CRT MNR PWR MJR A B C E D F H I K M G J L Front Panel Buttons A Power button Toggles the system power B Reset button Resets the system G NMI button Ass...
Page 22 - Server Platform Peripherals
Server Platform Features J NIC activity LED (green) Indicates activity on either NIC. K Main power LED (green) When continuously lit, indicates the presence of DC power in the server. The LED goes out when the power is turned off or if the power source is disrupted. L Disk 1 Activity/Fault LED (gree...
Page 23 - Server Board Connector and Component Locations
Server Platform Features Server Board Connector and Component Locations TP01646 B A C D E F G H I J L R Q N M O P K A. SCSI Channel B J. Fan board connector B. Battery K. Secondary IDE channel C. Full-height riser slot L. 24-pin SSI power connector D. Low-profile riser slot M. 50-pin control panel c...
Page 24 - Configuration Jumpers
Server Platform Features Configuration Jumpers TP01652 J1H2 3 2 A1-A2: CMOS Clear by BMC 1-2: Default A2-A3: CMOS Clear Force EraseB1-B2: Recovery Boot Disable (Normal Boot)B2-B3: Recovery Boot EnableC1-C2: Password Clear ProtectC2-C3: Password Clear Erase C B A Figure 7. Configuration Jumper Locati...
Page 25 - Features; FPIO SCSI Subsystem Status LEDs
Server Platform Features Front Panel IO (FPIO) System Board Features The TIGI2U server system has the following FPIO features: • Four switches to control power-on, reset, NMI, and the system ID LED • One system ID LED that can be controlled remotely or by the system ID switch • Two system activity L...
Page 26 - Peripheral Bay; NOTE
Server Platform Features Peripheral Bay One peripheral drive (either a slim-line CD-ROM drive or a slim-line DVD-ROM drive) can be mounted in the system using a blind-mate peripheral drive carrier inserted into the peripheral drive bay. The peripheral drive bay is located above the hard drive tray a...
Page 27 - Power Supply
Server Platform Features Power Supply The power supply cage supports up to two hot-swap power supplies (either AC input or DC input) in a (1+1) redundant configuration. A power supply filler module for the empty power supply site is supplied for systems without redundancy. Only the DC input version ...
Page 28 - System Cooling; Processor
Server Platform Features System Cooling All system components except the power supply cage are cooled by a set of fans mounted near the middle of the chassis and behind the hard drive bays. The TIGI2U system comes in a non-redundant, four-fan configuration that consists of two 80mm x 38mm fans and t...
Page 29 - Memory; Memory Sparing and Mirroring
Server Platform Features Memory The Server Board SE7520JR2 provides six DIMM sockets across two channels, Channel A and Channel B. Channel A consists of DIMM sockets 1A, 2A, and 3A. Channel B consists of DIMM sockets 1B, 2B, and 3B. If six DIMMs are installed, the following maximum capacitites are p...
Page 31 - NOTES
Server Platform Features NOTES Although the server board architecture allows the user to mix various sizes of DIMMs between channels, DIMMs must be identical within each bank. To be fully compliant with all applicable DDR SDRAM memory specifications, the board should be populated with DIMMs that sup...
Page 33 - Platform Installations and Upgrades; Before You Begin; Tools and Supplies Needed
Platform Installations and Upgrades Platform Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the safety instructions at the beginning of this manual. See “Safety Information.” Tools and Supplies Needed Phillips* (cross head) screwdriver (#1...
Page 35 - Removing and Installing the Chassis Cover; Removing the Chassis Cover
Platform Installations and Upgrades Removing and Installing the Chassis Cover Removing the Chassis Cover The Intel ® Carrier Grade Server TIGI2U must be operated with the top cover in place to ensure proper cooling. You will need to remove the top cover to add or replace components inside of the pla...
Page 36 - Installing the Chassis Cover
Platform Installations and Upgrades Installing the Chassis Cover 1. Place the cover over the chassis so that the side edges of the cover sit just inside the chassis sidewalls, with the front of the cover with about 1/8-inch gap showing between the chassis cover and the sheet-metal at the front of th...
Page 37 - Removing and Installing the Front Bezel; Removing the Front Bezel
Platform Installations and Upgrades Removing and Installing the Front Bezel The front bezel needs to be removed only to install or remove hot-swap hard drives or the CDROM drive. Removing the Front Bezel 1. Loosen the captive screws at the left and right edges of the front bezel (one screw at the ri...
Page 38 - Installing the Front Bezel
Platform Installations and Upgrades Installing the Front Bezel 1. While holding the front bezel in place (see letter “A”), tighten the captive screws at the left and right edges of the bezel (see letter “B”). TP01651 A B B Figure 13. Installing the Front Bezel Intel ® Carrier Grade Server TIGI2U Use...
Page 39 - Removing and Installing the Processor Air Duct; Removing the Processor Air Duct
Platform Installations and Upgrades Removing and Installing the Processor Air Duct The air duct must be removed to access the processor assembly and the four-fan assembly. The processor air duct is required for proper airflow within the chassis. Be sure the air duct is in place before installing the...
Page 40 - Installing the Processor Air Duct
Platform Installations and Upgrades Installing the Processor Air Duct 1. Place the processor air duct over the processor socket and four-fan assembly, using caution to make sure you do not pinch any wires beneath the edges of the air duct (see letter “A”). 2. Tighten the screws at the top of the air...
Page 41 - Installing and Removing Memory DIMMs; Installing DIMMs
Platform Installations and Upgrades Installing and Removing Memory DIMMs The silkscreen on the board for the DIMMs displays DIMM1B, DIMM1A, DIMM2B, DIMM2A, DIMM3B and DIMM3A, starting from the outside of the board. DIMM1B is the socket closest to the outside edge of the server board. Installing DIMM...
Page 42 - Removing DIMMs; Replacing the Processor
Platform Installations and Upgrades 9. Replace the chassis cover if you have completed all work inside of the platform. For instructions, see “ Installing the Chassis Cover .” Removing DIMMs To remove a DIMM, follow these steps: 1. Power down the server system and unplug all peripheral devices and t...
Page 43 - Removing the Processor
Platform Installations and Upgrades Removing the Processor 1. Power down the server system and unplug all peripheral devices and the AC power cable or the DC mains. 2. Remove the chassis cover. For instructions, see “ Removing the Chassis Cover .” 3. Remove the processor air duct that covers the pro...
Page 44 - Installing the Processor
Platform Installations and Upgrades Installing the Processor To install a processor, follow these instructions: 1. Power down the server system and unplug all peripheral devices and the AC power cable or the DC mains. 2. Remove the chassis cover. For instructions, see “ Removing the Chassis Cover .”...
Page 46 - Installing or Removing a Hard Drive; Installing a Hard Drive
Platform Installations and Upgrades Installing or Removing a Hard Drive Up to two hot-swappable SCSI drives can be installed in your chassis. It is not necessary to remove the chassis cover to add or replace a hot-swap hard drive. It is necessary to remove the front bezel from the chassis. CAUTION T...
Page 48 - Removing a Hard Drive; Replacing the CD-ROM Drive
Platform Installations and Upgrades Figure 24. Inserting Hard Disk Drive Assembly into Chassis 10. Install the front bezel. Install the front bezel. For instructions, see “Installing the Front Bezel.” Removing a Hard Drive 1. Remove the front bezel. For instructions, see “Removing the Front Bezel.” ...
Page 51 - Installing or Removing a PCI Add-in Card; Installing a PCI Add-in Card
Platform Installations and Upgrades Installing or Removing a PCI Add-in Card CAUTION PCI cards in this system are NOT hot swappable. Before removing or replacing the PCI card, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system ...
Page 53 - Removing a PCI Add-in Card
Platform Installations and Upgrades TP01695 B A C Figure 29. Installing Full Length PCI Card into Riser 6. Insert the PCI riser assembly into the chassis. 7. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” Removing a PCI Add-in Card 1. Power down the server system an...
Page 55 - Replacing the Power Supply; Removing the Power Supply
Platform Installations and Upgrades Replacing the Power Supply CAUTION Your server does not have a redundant power supply unless you have purchased the optional second power supply. Before replacing the power supply, you must first take the server out of service, turn off all peripheral devices conn...
Page 56 - Installing the Power Supply; DC Power In Male Connector Configuration
Platform Installations and Upgrades Installing the Power Supply 1. When inserting the new power supply, make sure the green handle is depressed downward while sliding the module into the power supply cage. TP01654 Figure 33. Installing the Power Supply 2. Install the chassis cover. For instructions,...
Page 57 - Grounding a DC Powered System; Replacing the Four-Fan Assembly
Platform Installations and Upgrades Grounding a DC Powered System The DC chassis provides two #10-32 threaded studs for chassis enclosure grounding. A single 90º standard barrel two-hole compression terminal lug with 5/8-inch pitch suitable for #14-10 AWG conductor (such as the Thomas & Betts te...
Page 58 - Removing the Four-Fan Assembly
Platform Installations and Upgrades Removing the Four-Fan Assembly 1. Power down the server system and unplug all peripheral devices and the AC power cable or the DC mains. 2. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.” 3. Remove the processor air duct. For instruct...
Page 59 - Installing the Four-Fan Assembly
Platform Installations and Upgrades Installing the Four-Fan Assembly 1. Lower the fan module into place (see letter “A”). 2. Tighten the captive screw (see letter “B”). 3. Connect the fan cables to the correct fan connectors on the front panel I/O board (see letter “C”). The fan connectors are label...
Page 60 - Replacing the Mini-Bezel
Platform Installations and Upgrades Replacing the Mini-Bezel The mini bezel is installed over the front panel controls and LEDs. To replace the mini bezel, use the following instructions. It is not necessary to power down the server to replace the mini-bezel. 1. Remove the front bezel. For instructi...
Page 61 - Replacing the Front Panel I/O Board; Removing the Front Panel I/O Board
Platform Installations and Upgrades Replacing the Front Panel I/O Board The Front Panel I/O Board provides an interface to the controls at the front of the server system, the power interconnect for the server board, the USB2 and Serial B interface, and the front panel LED interface connect. To repla...
Page 63 - Replacing the Light Pipe
Platform Installations and Upgrades Replacing the Light Pipe Light pipe replacement instructions are included as part of the instructions to replace the front panel I/O board. To replace the light pipe using an existing front panel I/O board, use the instructions under the following headings, replac...
Page 64 - Installing the Front Panel I/O Board
Platform Installations and Upgrades Installing the Front Panel I/O Board 1. Lower the replacement Front Panel I/O Board into the chassis (see letter “A”). 2. While holding the rear edge of the board, ease the board forward, sliding the NIC connector and USB port through the matching cutout at the fr...
Page 66 - Replacing the PCI Riser Board
Platform Installations and Upgrades Replacing the PCI Riser Board CAUTION Before replacing any of the server boards, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord ...
Page 68 - Replacing the Power Interface Board
Platform Installations and Upgrades TP01697 C D A B Figure 46. Installing the Full Height PCI Riser Board 11. Install the PCI card(s). For instructions, see “Installing a PCI Add-in Card.” 12. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” Replacing the Power Interf...
Page 69 - Removing the Power Interface Board
Platform Installations and Upgrades Removing the Power Interface Board 1. Power down the server system and unplug all peripheral devices and the AC power cable or the DC mains. 2. Remove the chassis cover. For instructions, see “ Removing the Chassis Cover.” 3. Remove the PCI riser assembly. For ins...
Page 70 - Installing the Power Interface Board; Replacing the Serial/Alarms Cable
Platform Installations and Upgrades Installing the Power Interface Board 1. Press down on the power interface retention lever (see letter “A”) and lower the replacement power interface board into place (see letter “B”). 2. Make sure that the power interface board is placed over the placement pegs an...
Page 71 - Removing the Serial/Alarms Cable
Platform Installations and Upgrades Removing the Serial/Alarms Cable 1. Power down the server system and unplug all peripheral devices and the AC power cable or the DC mains. 2. Remove the chassis cover. For instructions, see “ Removing the Chassis Cover.” 3. Remove the threaded standoffs as shown i...
Page 72 - Installing the Serial/Alarms Cable
Platform Installations and Upgrades Installing the Serial/Alarms Cable 1. Install the serial/alarms connector into the chassis. See Figure 51. TP01681 Figure 51. Installing the Serial/Alarms Connector into Chassis 2. Install the threaded standoffs as shown in Figure 52. TP01682 Figure 52. Installing...
Page 73 - Replacing the Server Board; Removing the Server Board
Platform Installations and Upgrades Replacing the Server Board The Intel ® Carrier Grade Server TIGI2U uses the Intel ® Server Board SE7520JR2. To replace the server board, the following components must be removed: All cable connections on the server board Heat sink(s) Processor(s) All DIMMs PCI ris...
Page 75 - Installing the Server Board
Platform Installations and Upgrades Installing the Server Board 1. If you have a SCSI cable to connect, do this first before installing the server board (see letter “A” in the figure below). 2. Set the replacement board into place (see letter “B” in the figure below), using caution to make sure no c...
Page 77 - Replacing the Backup Battery
Platform Installations and Upgrades Replacing the Backup Battery The lithium battery on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings (for example, the date and time) stored in CMOS RAM (Random...
Page 79 - Installing or Replacing the Power Cord; Installing the Platform into a Rack
Platform Installations and Upgrades Installing or Replacing the Power Cord NOTE If you will be placing your server in a rack, wait to install the power cord until after the server is in the rack. Plug the power cord into the power supply. Installing the Platform into a Rack Installation instructions...
Page 82 - Server Utilities; Using the BIOS Setup Utility; Starting Setup; If You Cannot Access Setup
Server Utilities Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See “ Additional Information and Software ” for a lin...
Page 84 - Upgrading the BIOS; Preparing for the Upgrade; Recording the Current BIOS Settings; Obtaining the Upgrade
Server Utilities Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include the following: On-board system BIOS, including the recovery code, BIOS Setup Utility, and strings. On-board video BIOS, SCSI BIOS, and other option RO...
Page 85 - Clearing the Password
Server Utilities Upgrading the BIOS Follow the instructions in the readme file that came with the BIOS upgrade. When the update completes, remove the bootable media from which you performed the upgrade. NOTES Do not power down the system during the BIOS update process! The system will reset automati...
Page 86 - Clearing the CMOS
Server Utilities 4. Reconnect the AC power or DC mains, power up the system. 5. Power down the system and disconnect the AC power or DC mains. 6. Return the Password Clear jumper to the Password Clear Protect position, covering pins 1 and 2. 7. Close the server chassis. 8. Reconnect the AC power or ...
Page 87 - Troubleshooting; Resetting the System
Troubleshooting Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system. For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS and the baseboard management controller (BMC). See “...
Page 88 - Problems following Initial System Installation; First Steps Checklist
Troubleshooting Problems following Initial System Installation Problems that occur at initial system startup are usually caused by an incorrect installation or configuration. Hardware failure is a less frequent cause. If the problem you are experiencing is with a specific software application, see “...
Page 89 - Hardware Diagnostic Testing; Verifying Proper Operation of Key System Lights
Troubleshooting Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. CAUTION Turn off devices before disconnecting cables: Before disconnecting any peripheral cables from the system, turn off the system and any external...
Page 90 - Confirming Loading of the Operating System; Specific Problems and Corrective Actions; Power Light Does Not Light
Troubleshooting Confirming Loading of the Operating System Once the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the operating system prompt does not appear, see “ No Characters Appear on Screen .” Specific Problems and C...
Page 92 - System Cooling Fans Do Not Rotate Properly; CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light
Troubleshooting System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. Check the following: Is the power-on light lit? If not, see “ Power Light Does Not Light ” Are any other front panel LEDs lit? H...
Page 93 - Problems with Network; System Boots when Installing PCI Card
Troubleshooting Problems with Network The server hangs when the drivers are loaded. Certain drivers may require interrupts that are not shared with other PCI drivers. For these drivers, it may be necessary to alter settings so that interrupts are not shared. See the documentation that came with your...
Page 94 - Problems with Newly Installed Application Software
Troubleshooting Problems with Newly Installed Application Software Problems that occur when you run new application software are usually related to the software, not the server hardware. Faulty equipment is unlikely, especially if other software runs correctly. Check the following: Make sure the sys...
Page 95 - Bootable CD-ROM Is Not Detected
Troubleshooting Devices are not Recognized under Device Manager (Windows* Operating System) The Windows* operating systems do not include all of the drivers for the Intel ® chipsets, onboard NICs, and other components. See “ Additional Information and Software ” for a link to the current drivers and...
Page 96 - LED Information
Troubleshooting LED Information The Intel ® Server Board TIGI2U includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. LED Name Function Location Color Notes ID Aid in server identification from the back panel Control panel a...
Page 98 - BIOS POST Beep Codes
Troubleshooting BIOS Error Messages (continued) Error Message Explanation Memory Size Decreased Memory size has decreased since the last boot. If no memory was removed, then memory may be bad. Memory Size Increased Memory size has increased since the last boot. If no memory was added, there may be a...
Page 100 - Regulatory and Certification Information; Product Regulatory Compliance; Product Safety Compliance
Regulatory and Compliance Information Regulatory and Certification Information Product Regulatory Compliance Product Safety Compliance The Server Board TIGI2U complies with the following safety requirements: UL60950 – CSA 60950(USA / Canada) EN60950 (Europe) IEC60950 (International) CB Certificate &...
Page 101 - Certifications / Registrations / Declarations; Product Regulatory Compliance Markings
Regulatory and Compliance Information Certifications / Registrations / Declarations UL Certification (US/Canada) CE Declaration of Conformity (CENELEC Europe) FCC/ICES-003 Class A Attestation (USA/Canada) VCCI Certification (Japan) C-Tick Declaration of Conformity (Australia) BSMI Certification (Tai...
Page 102 - Electromagnetic Compatibility Notices
Regulatory and Compliance Information Table 10. Product Certification Markings Regulatory Compliance Country Marking BSMI Certification Number & Class A Warning Taiwan GOST R Marking Russia RRL MIC Mark Korea China Compulsory Certification Mark China Electromagnetic Compatibility Notices FCC (US...
Page 104 - Korean RRL Compliance
Regulatory and Compliance Information VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domesti...
Page 105 - Regulated Specified Components
Regulatory and Compliance Information Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following conditions must be adhered to and the following regulated components must be used. Interchanging or using other compone...
Page 106 - Getting Help; World Wide Web
Getting Help Getting Help World Wide Web http://support.intel.com/support/motherboards/server/TIGI2U Telephone All calls are billed at US $25.00 per incident, and levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the prici...
Page 107 - Brief Problem Description.
Intel® Server Issue Report Form Intel ® Server Issue Report Form NOTE An on-line / automatic submission version of this form is available at http://support.intel.com/support/motherboards/server/TIGI2U . For the fastest service, please submit your form via the Internet. Date Submitted: Company Name: ...
Page 108 - Board / Chassis Information
Intel® Server Issue Report Form Board / Chassis Information Baseboard Revision – PBA#: DIMM Configuration Baseboard Serial Number: DIMM1A MB: CPU1 Speed/Stepping/Spec: DIMM1A Vendor/part number: System BIOS Version: DIMM1B MB: Platform Model DIMM1B Vendor/part number: Intel ® TIGI2U DIMM2A MB: DIMM2...
Page 109 - Operating System Information; Peripheral Information; Hard Drive Information:
Intel® Server Issue Report Form Operating System Information Operating System Version Service Pack Peripheral Information Check each box below that is used, and provide the requested information Peripheral Card Or Peripheral Description Driver Revision IRQ # I/O Base Address FW Rev# Low-profile Rise...
Page 110 - Complete Problem Description
Intel® Server Issue Report Form Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. Intel ® Carrier Gra...
Page 111 - Warranty; Extent of Limited Warranty
Warranty Warranty Limited Warranty for Intel ® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel ® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and in...
Page 112 - Warranty Limitations and Exclusions; Limitations of Liability
Warranty Warranty Limitations and Exclusions These warranties replace all other warranties, expressed or implied, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel makes no expressed warranties beyond those stated here. Intel disclaim...
Page 113 - How to Obtain Warranty Service; Telephone Support
Warranty How to Obtain Warranty Service To obtain warranty service for this Product, you may contact Intel or your authorized distributor. North America and Latin America ⎯ To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support.intel.com...
Page 114 - Returning a Defective Product
Warranty Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel ® Carrier Grade Server TIGI2U User Guide 114