Page 2 - Henny Penny Blast Chiller/Freezer
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Henny Penny Blast Chiller/Freezer BFR/BCR-350 BCC/BCR-175 BCC/BCR-140
Page 3 - LIMITED WARRANTY FOR HENNY PENNY APPLIANCES
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 LIMITED WARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts: NEW EQUIPMENT: Any ...
Page 4 - TABLE OF CONTENTS; Section
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ................................................................................................................... 1-1 1-1. Henny Penny Blast Chiller .........................................
Page 5 - SECTION 1. INTRODUCTION
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 1-1 SECTION 1. INTRODUCTION 1-1. BLAST CHILLER/ The Henny Penny Blast Chiller are designed to carry out fastrefrigeration of food products. The units are electronically con-trolled for easy use and for consistent operation. TheBCC/BCR-140, ...
Page 6 - NOTE
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 1-5. SAFETY The Henny Penny Blast Chiller has may safety features incorpo-rated. However, the only way to ensure a safe operation is to fullyunderstand the proper installation, operation, and maintenanceprocedures. The instructions in this manu...
Page 7 - SECTION 2. INSTALLATION; Carefully cut banding straps.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 2. INSTALLATION 2-1. INTRODUCTION This section provides the installation for the Henny PennyBlast Chiller. NOTE Installation of this unit should be performed only by aqualified service technician. Do not puncture the skin of the Blast C...
Page 8 - Open door and remove packing from the inside of the unit.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 (Continued) 2-2 201 2-2. UNPACKING 4. Open door and remove packing from the inside of the unit. 5. Peel off any protective covering from the exterior of thecabinet. 6. Your Blast Chiller is now ready for operation. If the blast chiller has been...
Page 9 - Refer to the table below for electrical ratings for both models.; Volts; Clearances should be as follows:; Pass Thru
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 2-3 2-3. ELECTRICAL Refer to the table below for electrical ratings for both models. (Continued) Model No. Volts Watts Amps Freq. Phase BCC-140 200 4700 18 50/60 3 208-240 4700 18 60 3 230 4700 20 50 1 BCC-175 200 5800 20 50/60 3 208-240 58...
Page 10 - Design Pressure; CAPACITIES
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 2-5. REFRIGERANT INFORMATION Design Pressure Refrigerant Type Amount of Refrig. High Low BCC-140 R404A 6 lbs. (2.7 kg) 406 psig 102psig (28 bar) (7 bar) BCC-175 R404A 5.5 lbs. (2.4 kg) 406 psig 102 psig (28 bar) (7 bar) 2-6. REFRIGERATION BCC/B...
Page 11 - SECTION 3. OPERATION; Item
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 3. OPERATION 3-1. INTRODUCTION This section provides operating procedures for the Blast Chiller.Sections 1, 2, and 3 should be read, and all instructions should befollowed before operating the cabinet. This section contains an explanati...
Page 15 - Press the Select button to choose the food probe mode or; Set the time in the timing cycle, if necessary, using the Up; The product can remain in the unit for up to 12 hours, or
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3. BASIC OPERATION 5. Press the Select button to choose the food probe mode or the timing mode. With the Frigiprobe mode selected, thedigital display will alternately show the core temperature ofthe product, and the elapsed time of the cycle....
Page 16 - A temperature conversion chart is provided for your
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3. BASIC OPERATION A temperature conversion chart is provided for your (Continued) convenience: 200 3-6
Page 17 - Press the De-ice button. The digital display will now show
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-4. DE-ICING Henny Penny recommends to perform the de-icing process afterevery 3 cycles, and at the end of each day. This will eliminate anyice that may have formed around the evaporator during the chillingcycle. Failure the follow this proced...
Page 18 - DO NOT
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-5. CLEANING Daily: 1. Remove all electrical power supplied to the unit by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the racks and pans from the unit and clean with soap and water at a sink. 4. Clean ...
Page 20 - Press the Alarm button three; Type of program setting indicated by the jumper; Press the Alarm
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING Information about the operation settings can be accessed bypressing the Alarm button. These settings can also be changedwhile in the different steps. The following information can beaccessed: NOTE After pressing the Alarm butto...
Page 21 - The holding temperature; Evaporator temperature for the end of de-icing cycle.; Press the Alarm button 9 times and the digital display
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING The holding temperature can be changed at this time by (Continued) using the Up and Down buttons. Factory setting for airtemperature is 37ºF (3ºC). The minimum temperaturesetting is 32ºF (0ºC), and the maximum temperature is50º...
Page 22 - The duration of time the temperatures, (in 9 and 10; Press the Alarm button 11 times and the digital display will; Press the
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 11. The duration of time the temperatures, (in 9 and 10 (Continued) above), must remain at before the alarms will sound. Press the Alarm button 11 times and the digital display will 1 0 show the time at which the high and low t...
Page 23 - Frigiprobe, end of cycle temperature setting.; England is
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 14. Blast chilling, low side air temperature limit, when usingthe Frigiprobe, in step 12 of this section. Press the Alarm button 14 times and the low side air temperature, at which 2 0 the compressor cycles on and off, will sho...
Page 24 - Frigiprobe temperature for when the buzzer sounds at; Press the Alarm button 17 times, and; Press the Alarm button
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 17. Frigiprobe temperature for when the buzzer sounds at (Continued) the start of a cycle. Press the Alarm button 17 times, and the temperature that the buzzer will sound when the product 2 3 has reached the “danger zone” tempe...
Page 25 - SECTION 4. TROUBLESHOOTING
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 4. TROUBLESHOOTING 4 - 1. INTRODUCTION This section provides troubleshooting information in the form of an easy to read table. If a problem occurs during the first operation of a new cabinet,recheck the installation per section 2 of thi...
Page 27 - Problem
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Problem Cause Correction Slow to decrease Condenser obstructed by dirt. Clean the Condenser. in temperature (decline inperformance) Evaporator iced up. Perform a de-icing cycle. Refrigerating problem Check refri...
Page 33 - Quantity BFR/
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Quantity BFR/ Item BCC BCR BCC BCR BCR No. Part No. Description 140 140 175 175 350 1 9504.0205 Control PC Board 1 1 1 1 1 2 9503.3692 Display PC Board 1 1 1 1 1 3 9503.3700 Auxiliary Display Board 1 1 1 1 1 4 9503.3759 Connecting Cable 1 1 1 1...
Page 34 - Quantity BFR/; High Limit Safety Thermostat
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Quantity BFR/ Item Part BCC BCR BCC BCR BCR No. No. Description 140 140 175 175 350 31 9500.8967 Nozzle-Expansion Valve BFR-350 - - - - 2 32 9500.7993 Water Pressure Valve - BCC-175 - - 1 - - 33 9503.6182 High Pressure Switch - BCC-140 1 - - - ...