Page 2 - Installers Guide; DO NOT; Owners Guide; ALERTED; SAFETY AND WARNING INFORMATION
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly to ...
Page 3 - TABLE OF CONTENTS
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 3 TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .............
Page 4 - Log set assembly; Service Parts
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 16 4 5 14 1 5 1 3 2 3 1 1 7 10 7 9 8 11 12 6 Log set assembly 1 8 (NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces Serv...
Page 5 - IN T E R MIT T E N T P IL OT IGN IT ION (IP I)* / IP I AL LU MAGE S E U L E ME N T; Service Parts List / Liste des pièces de rechange; L'information fournie dans cette brochure
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 5 IT EM / P IÈ C E C OMMON PAR TS / P IÈ C ES C OMMU N ES S ER IAL # / N° DE SÉRIE PAR T N U MB ER / N ° D E P IÈ C E 1 S urround / E ntourent P RE 002 32400 2P OS T 0 0232 4002 3 85-13 0 2 026 -108 2 Hoo d / Hotte SRV60-143-BK 3 Glass...
Page 6 - Intermittent Pilot Ignition
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 6 (NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces Service Parts Beginning Manufacturing Date: 7-03 Ending Manufacturing Date: ______ IT E M / P IÈ C E D E S C R IP T ION S E R IAL # / N° DE SÉRIE PAR T N U MB E R / N ° D...
Page 7 - PIÈ C E; Standing Pilot Ignition
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 7 (NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces Service Parts Beginning Manufacturing Date: 7-03 Ending Manufacturing Date: ______ ITEM / PIÈ C E DESCRIPTION SERIAL # / N° DE SÉRIE PART NUMBER / N° DE PIÈCE 1 Control P...
Page 8 - Appliance Certification; The Heat & Glo fireplace models discussed in this; Certification; Underwriters Laboratories; Installation Codes
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: 6000TRI-IPI, 6000TRI-SP LABOR...
Page 9 - Getting Started; Introducing the Heat & Glo Gas Fireplaces; Pre-install Preparation; Do not install any
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 9 2 Getting Started Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper-ate with all combustion air siphoned from outside of thebuilding and all exhaust gases expelled to the out...
Page 11 - Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections; Constructing the Fireplace Chase
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 11 3 Installing the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require-ments for locating a fireplace within a room. Minimum Clearances from the Fireplace to Combustible Materials Inches mm...
Page 12 - Framing Dimensions; Step 2. Framing the Fireplace
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 12 Framing should beconstructed of 2 X 4lumber or heavier. A . ............. 42”* B . ......... 38 1/2” C . ............... 22” D . ......... 42 3/4” E . ......... 27 7/8” Figure 3. Framing Dimensions Step 2. Framing the Fireplace Fire...
Page 14 - Step 3. Installing the Vent System; SERIES
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 14 Figure 5. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use DVP-series direct ventpipe components and terminations (see Figures 4 and 5).Approved...
Page 15 - STRAIGHT UP; VERTICAL VENTING; Flue Restrictor Instructions; Figure 8. Flue Restrictor; On vertical venting
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 15 Figure 6.Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V (FT.) 40' MAX. (12.4 M) Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver byremoving the four screws securing it in place (seeFigure 7)...
Page 16 - HORIZONTAL VENTING; Figure 11. Corner Installation; Match the amount of vertical you have in the sys-; . Center the Flue Restrictor on vent and secure in; Figure 9
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 16 HORIZONTAL VENTING Kit No. H Max. Run DVP-TRAP 24" (610 mm) Figure 11. Corner Installation NOTE: This model is tested and approved to use45° elbows in corner installations. However, 90°elbows will result in better performance. T...
Page 17 - On vertical venting configurations where; Figure 12. Venting with One 90° Elbow; elbow is first attached to the unit,
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 17 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) NOTE: On vertical venting configurations where the vertical c...
Page 18 - ELBOWS
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 18 Figure 14. Venting with Two 90° Elbows VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m...
Page 19 - Figure 16. Venting with three 90° elbows; V H H + H
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 19 Figure 16. Venting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX....
Page 20 - Figure 17. Venting with three 90° elbows
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 20 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H 1 = 20' MAX. (6.2m) V + V 1 + H + H 1 = 4...
Page 21 - B. Installing Vent Components; Venting Out Rear
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 21 ! B. Installing Vent Components After determining which set of starting collars will be used(top or rear), follow venting instructions accordingly. Venting Out the Rear Vent Remove the installed rear seal cap from the rear startingc...
Page 23 - REQUIRED
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 23 5. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exteriorfirestop on an exterior combustible wall. To install ...
Page 24 - Figure 28. Trapezoid Termination Cap; If the area above the ceiling is; NOT; an attic, position and; IS; an attic, position and secure; Figure 27. Attic Firestop
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 24 Figure 28. Trapezoid Termination Cap 7 1/4” (184mm) Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previouslycut and fram...
Page 25 - = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 29. Vent Termination Minimum Clearances; public
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 25 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Vent Termination Minimum Clearances A = 12" ....................... clearances above grade, veran- da, porch, deck or balcony B = 12" ....
Page 27 - Step 6. The Gas Control Systems; The types of gas control systems used with this model are; Step 5. Installing the Optional Heat-Zone Kit; There must be NO INSULATION or other com-; Do this; FORE; final positioning of the fireplace.; Standing Pilot Ignition System
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 27 ! ! Step 6. The Gas Control Systems WARNING: THIS UNIT IS NOT FOR USE WITHSOLID FUEL. The types of gas control systems used with this model are Intermittent Pilot Ignition (IPI) and Standing Pilot Ignition (SP). WARNING: CONTINUOUS ...
Page 28 - Figure 35. Gas Supply Line; Step 7. The Gas Supply Line; Pressure
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 28 Figure 35. Gas Supply Line • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between thepipe...
Page 30 - Step 9. Wiring the Fireplace; This appliance
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 30 Figure 38. Fan Wiring Diagram NOTE: IF ANY OF THE ORIGINAL WIREAS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE. O JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN ...
Page 31 - require; Figure 40. Sealant Material; FINISH WALL MATERIAL MAY BE; There are 3 metal tabs holding the non-combustible
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 31 Step 10. Finishing Figure 39 shows the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels or othercombustible projections above the top front edge of thefireplace. See Figures 2 and 3 for other fire...
Page 33 - Step 12. Before Lighting the Fireplace
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 33 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information sec...
Page 34 - Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing; Step 13. Lighting the Fireplace
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 34 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician perf...