Page 2 - Models; Pistol Grip, Base Seal; Contents
Models 2 309739 Models Pistol Grip, Base Seal Pistol Grip, Tip Seal Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Grounding and Electrical Requirements . . . . . . . . 4 Installatio...
Page 3 - Warnings; Warning
Warnings 309739 3 Warnings Warning E LECTRIC S HOCK H AZARD Improper grounding, setup, or usage of the system can cause electric shock.• Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. • All electrical wiring must be done by a qualified el...
Page 4 - Grounding and Electrical Requirements
Grounding and Electrical Requirements 4 309739 Grounding and Electrical Requirements The following are minimum requirements for a basic dis-pensing system. Your system may include other equip-ment or objects that must be grounded. Check your local electrical code for detailed grounding instructions ...
Page 5 - Installation; Pressure Relief Procedure; Trigger Lock
Installation 309739 5 Installation Inspect flow gun for shipping damage. If damage is found notify the carrier immediately. 1. Connect flow gun to any standard Graco hose assembly. 2. Connect the opposite end of the heated hose assembly to any fluid supply system. See Model table, page 2 for maximum...
Page 6 - Troubleshooting
Troubleshooting 6 309739 Troubleshooting Problem Cause Solution Gun fails to dispense when trigger is actuated Material lodged in nozzle Follow Pressure Relief Procedure, page 5. Clear nozzle of blockage. Material supply, hose, passages, clogged Check material supply settings, hoses, etc. for proper...
Page 8 - Service
Service 8 309739 Service Models 12004, 12004X Disassembly 1. Actuate gun to purge material and relieve pressure in gun. Pressure Relief Procedure, page 5. 2. Disconnect material supply line from gun handle. 3. Hold adapter (9) stationary and unscrew nozzle and collar (16). 4. With trigger depressed,...
Page 10 - Reassembly
Service 10 309739 Reassembly Clean all parts thoroughly before reassembling. Check them carefully for damage or wear, replacing parts as needed. For best results replace the original parts with new parts in repair kits. Prior to assembly, lubricate all seals and o-rings with PARKER-O-LUBE or an equi...
Page 12 - Parts
Parts 12 309739 Parts Models 12004 & 12004X 13 1 2 3 5 6 7 4 11 23 12 16 9 10 8 15 14 17 18 21 19 20 Item Part No. Description Qty 1 C27052 YOKE 1 2 100284 NUT, hex (model 12004) 1 C19284 NUT, hex (model 12004-X) 1 3 C27061 SCREW, adjustment 1 4 106555 PACKING, o-ring 1 5 C27058 PACKING, nut 1 6...
Page 15 - Technical Data
Technical Data 309739 15 Technical Data Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . Models 12004X, 12004, and 12005: 2500 psi (17.2 MPa, 172 bar)Model 12006: 2000 psi (13.79 MPa, 137.9 bar) Inlet port size on gun housing . . . . . . . . . . . . . . . . . . . . . 1/2-14 NPTWe...
Page 16 - Graco Standard Warranty
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. This manual contains English. MM 309739 Graco Headquarters: Minneapolis International Offices: Bel...