Page 3 - TABLE OF CONTENTS; PRODUCT APPLICATION INFORMATION 12
Part # 4500195 (02/20/08) Page 3 TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . 2 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . 4 Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electrical Supply . . . . . . . . . . . . . . . . . . ....
Page 4 - SPECIFICATIONS; Gas Pressure
Part # 4500195 (02/20/08) Page 4 SPECIFICATIONS Gas Pressure Gas Supply (Min.) Operating Natural 7” w.c. 4.5 w.c Propane 11” w.c. 10” w.c. Individual Burner Input Ratings Burner Natural Gas Propane Input Btu/h Orifice Size DMS Input Btu/h Orifice Size DMS Open Burner 32,000 #37 28,000 1.5 mm Hot Top...
Page 5 - Model Designations Continued; SPECIFICATIONS Continued
Part # 4500195 (02/20/08) Page 5 Model Designations Continued Model Number Description PS-8-2020 Eight Open Burners w/(2) 20” Ovens PS-8-26 Eight Open Burners w/(1) 26” Oven PS-8 Eight Open Burners w/o Oven PS-12G-6-2020 12” Griddle, Six Open Burners w/(2) 20” Ovens PS-12G-6-26 12” Griddle, Six Open...
Page 7 - INSTALLATION; Siting; Installing The Backguard Or Shelf; Upright
Part # 4500195 (02/20/08) Page 7 INSTALLATION Siting The floor on which the appliance is to be sited must be capable of adequately supporting the weight of the appliance and any ancillary equipment. Units with ovens must be fitted with legs if installed on a combustible floor. Appliances Equipped Wi...
Page 8 - INSTALLATION Continued; Gas Connection
Part # 4500195 (02/20/08) Page 8 3. Securely fasten the support brackets to the burner box sides with (4) #14 x 5/8” Hex washer head, type B tapping screws. (Hardware package is supplied). Statutory Regulations The installation of this appliance must be carried out by a competent person and in accor...
Page 9 - Griddle Seasoning
Part # 4500195 (02/20/08) Page 9 A strong exhaust will create a vacuum in the room. For an exhaust vent to work properly, replacement air must enter the room. The amount of air that enters must be equal to the amount exhausted. All gas burners and pilots need sufficient air to operate. Large objects...
Page 10 - TESTING & ADJUSTMENT Continued; Open Top Burners; OPERATION; Thermostat Controlled Griddles
Part # 4500195 (02/20/08) Page 10 NOTE: The steel griddle surface will tone (blue discoloration) from the heat. This toning will not diminish function or operation and is not a defect. TESTING & ADJUSTMENT Continued Open Top Burners Lighting: 1. Light pilots. 2. Turn valve completely on. Burner ...
Page 11 - Standard Ovens; OPERATION Continued
Part # 4500195 (02/20/08) Page 11 CAUTION: Gas will flow to the top section burners even if top section pilots are not lit. Gas will not be interrupted. It is the responsibility of the operator to confirm the proper ignition of each burner as it is turned on. Should ignition fail to occur 5 seconds ...
Page 12 - PRODUCT APPLICATION INFORMATION; General
Part # 4500195 (02/20/08) Page 12 PRODUCT APPLICATION INFORMATION General The range is the workhorse of the kitchen because of its versatility. Most frequently used in small applications, such as cafes, schools, church kitchens, firehouses, and small nursing homes where demands are less taxing. The ...
Page 13 - PRODUCT APPLICATION INFORMATION Continued; Painted Finish; Stainless Steel
Part # 4500195 (02/20/08) Page 13 Center the load on the oven racks to allow for proper heat circulation around the sides. The oven will hold three, 18” x 26” (457mm x 660mm) sheet pans, six 12” x 20” x 2.5” (305mm x 508mm x 64mm) steam table pans, or one 17.75”x 25.75” (451mm x 654mm), roast pan. N...
Page 14 - CARE & CLEANING Continued; Griddle; Hot Tops
Part # 4500195 (02/20/08) Page 14 Open Top Burners Cleaning of the range top burner is a simple procedure, if done at regular intervals will prolong the life of the range and ensure good flame characteristics. 1 The most common problem with open burner range is spillage. Once the burner ports are pa...
Page 15 - WIRING DIAGRAMS
Part # 4500195 (02/20/08) Page 15 WIRING DIAGRAMS DESCRIPTION ITEM P A R T NUMBER REV W/D PS/SUN LEFT RC O V EN 1 4514771 0 GND 14 NC NO C 13 GRN LEFT RC O VEN SECTION O V EN DOOR SWITCH 11 16 15 BLK FR OM FR ONT SWITCH VIEWED 14 13 MO T O R INPUT 120 V O LT WHITE OR BLUE BLA C K OR BR O W N PER O V...
Page 16 - WIRING DIAGRAMS Continued
Part # 4500195 (02/20/08) Page 16 WIRING DIAGRAMS Continued DESCRIPTION ITEM P A R T NUMBER REV W/D PS/SUN RIGHT RC O VEN 1 4514772 0 RIGHT (SINGLE) RC O V EN SECTION 29 NC NO C 28 SWITCH O V EN DOOR 27 26 GND INPUT 120 V O LT GRN WHITE OR BLUE BLA CK OR BR O W N BLK SWITCH VIEWED FR OM FR ONT 11 29...
Page 21 - Plaques De Cuisson; ENTRETIEN ET NETT
Pa rt # 4500195 (02/20/08) Page 16 Une fois par semaine , netto yer soig neusement la surfac e du gril . Si nécessair e, utiliser une pierr e à gril ou un tampon à gril pour nett oy er la surfac e. F rott er dans le sens du grain du métal enc ore tiède . Il est possible d ’utiliser un déter gent pou...
Page 25 - Génér; FONCTIONNEMENT Suit
Pa rt # 4500195 (02/20/08) Page 12 INFORMA TIONS SUR LES APPLIC A TIONS DES PR ODUIT Génér alités La cuisinière est l ’appar eil le plus utilisé de la cuisine à cause de sa polyvalenc e. Elle est plus fr équemment utilisée dans les applications moins exigeantes t elles que les cafés , les écoles , l...
Page 31 - Désignations Des Modèles Suit; INTRODUC
Pa rt # 4500195 (02/20/08) Page 6 Désignations Des Modèles Suit Numéro de modèle Description PS-12-2626 Douze brûleurs ouv erts av. 2 f ours PS-12-26 Douze brûleurs ouv erts av. 1 f our PS-12G-10-2626 Gril 12 po, Dix brûleurs ouv erts av. 2 f ours PS-12G-10-26 Gril 12 po, Dix brûleurs ouv erts av. 1...
Page 32 - Désignations Des Modèles Suite; SPÉCIFICA
Pa rt # 4500195 (02/20/08) Page 5 Désignations Des Modèles Suite Numéro de modèle Description PS-8-2020 Huit brûleurs ouver ts av. 2 f ours 20 po PS-8-26 Huit brûleurs ouver ts av. 1 f our 26 po PS-8 Huit brûleurs ouver ts sans four PS-12G-6-2020 Gril 12 po, Six brûleurs ouv erts av. 2 f ours 20 po ...
Page 36 - POUR VO; CUISINIÈRES DE
Pa rt # 4500195 (02/20/08) Page 1 L ’att ention des utilisateurs est attir ée sur le fait que l’entr etien et les réparations doiv ent être eff ec tués par un agent d’entr etien autorisé par G arland utilisant des pièces de r echange d’orig ine Ga rland. G arland n ’aura aucune obligation en ce qui ...