Page 2 - IMPORTANT INFORMATION; California to cause birth defects or other reproductive harm.; Keep appliance area free and clear of combustibles.
Part #GCGTRAINING06 (03/03/08)) Page IMPORTANT INFORMATION WARNING: This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/cerami...
Page 3 - TABLE OF CONTENTS
Part #GCGTRAINING06 (03/03/08) Page 3 TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DIMENSIONS AND SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 WHAT IS A CHAIN GRIDDLE . . . . . . ...
Page 4 - DIMENSIONS AND SPECIFICATIONS
Part #GCGTRAINING06 (03/03/08)) Page DIMENSIONS AND SPECIFICATIONS INSTALLATION NOTES SPECIFY GAS TYPE ELECTRICAL CHARACTERISTICS Combustible Wall Clearances Operating Pressure Specifications Sides : 6" (15mm) Back : 6" (15mm) Natural : 7" W .C . (17 .mbar) Propane : 11" W .C . ( .mb...
Page 5 - WHAT IS A CHAIN GRIDDLE
Part #GCGTRAINING06 (03/03/08) Page 5 WHAT IS A CHAIN GRIDDLE Commercial chain restaurants impose strict food procedures on franchise owners and operators to guarantee the quality and consistency of the product . Beef burgers, hamburgers, french fries, onion rings, fried chicken and tortillas for ex...
Page 6 - INSTALLATION; Mechanical; WHAT IS A CHAIN GRIDDLE continued
Part #GCGTRAINING06 (03/03/08)) Page 6 During normal operation, the pilot flame is continually monitored . The flame current signal must maintain 0 .15 microamps minimum . Flame failure response time is 0 .8 seconds maximum . If at any time the ignition module does not detect a pilot flame, it will ...
Page 7 - Ventilation; INSTALLATION continued
Part #GCGTRAINING06 (03/03/08) Page 7 • Each thermostat controls one zone burner though a dual solenoid-pressure regulator valve complete with a pressure test spigot . Check the manifold gas pressure on each combination valve to make sure it is the same as that shown on the serial plate . The gas pr...
Page 8 - OPERATION & MAINTENANCE; Cleaning
Part #GCGTRAINING06 (03/03/08)) Page 8 . Re-set the thermostat to 75°F and apply a second film of oil . After (5) five minutes, wipe off the excess oil . 5 . Reset the thermostat to the cooking temperature and apply a final film of oil . After (3) minutes, wipe off the excess oil . The griddle is no...
Page 9 - SERVICING; Have The Right Tools And Instruments; Adjustments; Burner Air
Part #GCGTRAINING06 (03/03/08) Page 9 SERVICING Many factors affect the serviceability of equipment . In the chain griddle, there are more components to service than in older models . The new griddle is a compact design . Access to the temperature control circuitry and ignition units is easy . Servi...
Page 10 - Thermostat; Thermocouple; SERVICING continued
Part #GCGTRAINING06 (03/03/08)) Page 10 Thermostat Make sure the thermostat knob is correctly aligned with the dial indicator . To align the knob with the graduated dial correctly, follow this procedure . 1 . Turn the knob and shaft fully counter-clockwise . Loosen the set screw in the knob and alig...
Page 11 - Incandescent Lamps
Part #GCGTRAINING06 (03/03/08) Page 11 7 . The bayonet connector is spring loaded . Turn the connector so that it makes good contact with its seat on the plate, and adjust the spring so that at least 1” (5mm) of spring is available to push home . This is, it is loaded 1” (5mm) from the bayonet adapt...
Page 12 - Gas Valve Regulator; Power Switches
Part #GCGTRAINING06 (03/03/08)) Page 1 Gas Valve Regulator The gas valve regulator (See fig ) used on the griddle is AGA and CGA approved . The direction of gas flow is at right angles, right and left viewing the inlet . For setting the regulator: • For natural gas, Part #0510 regulator, set at 3 .5...
Page 13 - CONTROL PANEL SCHEMATIC DIAGRAM
Part #GCGTRAINING06 (03/03/08) Page 13 CONTROL PANEL SCHEMATIC DIAGRAM Figure 4 – Control schematic for a Model CG-48 Chain Griddle
Page 14 - FROM; – National Service Department; TO; – National Service Binder Holders; Subject: Thermocouples used in the Chain Griddle; hardware compensating methods .
Part #GCGTRAINING06 (03/03/08)) Page 1 SERVICE BULLETIN #95-5 FROM – National Service Department BULLETIN NO . #95-5 TO – National Service Binder Holders DATE – February , 1995 Subject: Subject: Thermocouples used in the Chain Griddle Models CG-36, CG-48, CG-60 & CG-72 This bulletin supplements ...
Page 16 - EMF In Millivolts - Reference Junction 0°F
Part #GCGTRAINING06 (03/03/08)) Page 16 Type J - Thermocouples (0° to 440°F) EMF In Millivolts - Reference Junction 0°F °F 0 1 2 3 4 5 6 7 8 9 10 0 -0 .885 -0 .868 -0 .831 -0 .803 -0 .776 -0 .78 -0 .71 -0 .69 -0 .666 -0 .639 -0 .611 10 -0 .611 -0 .583 -0 .556 -0 .58 -0 .501 -0 .73 -0 .5 -0 .18 -0 .3...
Page 17 - EMF In Millivolts - Reference Junction 0°C
Part #GCGTRAINING06 (03/03/08) Page 17 Type J - Thermocouples (0° to 240°C) EMF In Millivolts - Reference Junction 0°C °C 0 1 3 5 6 7 8 9 10 0 0 .000 0 .050 0 .101 0 .151 0 .0 0 .53 0 .303 0 .35 0 .05 0 .56 0 .507 10 0 .507 0 .550 0 .609 0 .660 0 .711 0 .76 0 .813 0 .865 0 .916 0 .967 1 .019 0 1 .01...