Preface Resource Orchestrator Documentation Road Map The documentation road map for Resource Orchestrator is as shown below. Resource Orchestrator Documentation Road Map For information about the documents for Resource Orchestrator, refer to "Chapter 1 Documentation Road Map" in the "Des...
Chapter 9 Changing Resources Explains how to change settings for the admin server or resources registered on the admin server. Chapter 10 Configuring the Operating Environments of Managed Servers Explains how to install software to the registered managed servers and set up their operating environmen...
Abbreviation Products VMware vCenter Server VMware(R) vCenter(TM) Server VMware vClient VMware(R) vClient(TM) VIOM ServerView Virtual-IO Manager BladeLogic BMC BladeLogic Server Automation ServerView Agent ServerView SNMP Agents for MS Windows (32bit-64bit)ServerView Agents LinuxServerView Agents VM...
- Red Hat, RPM and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc. in the UnitedStates and other countries. - Spectrum is a trademark or registered trademark of Computer Associates International, Inc. and/or its subsidiaries. - SUSE is a registered tra...
Contents Chapter 1 Login and Logout .....................................................................................................................................................1 Chapter 2 Home .....................................................................................................
Chapter 1 Login and Logout This chapter describes how to open and close the ROR console. Preparations Before opening the ROR console, be sure to read through the following instructions and restrictions. - When accessing the ROR console using Internet Explorer 8 or 9, be sure to enable the Compatibil...
Refer to "Chapter 10 Installing and Defining Single Sign-On" in the "Design Guide VE" for details on Single Sign-On. URL: https:// Admin_server_IP_address:23461/ On a Windows admin server, the ROR console can also be opened by selecting [start]-[All Programs]-[Resource Orchestrator]-...
Chapter 2 Home This chapter explains the ROR Console Home window display. When the ROR Console is started, the Home window is displayed. Refer to " Chapter 1 Login and Logout " for information on how to start the ROR Console. The elements of the Home window are explained below. - Functions l...
c. Set the following items: Schedule There is no specified format. When not displaying the date, leave this field blank. Enter up to 30 alphanumeric characters or symbols. Commas (",") cannot be used. Messages Enter up to 250 alphanumeric characters or symbols. d. Click [OK]. The information...
Chapter 3 Resource Management Overview This chapter provides an overview of the two views available on the [Resource] tab in Resource Orchestrator. Resource Orchestrator provides two different GUIs on the [Resource] tab: the default window and BladeViewer.Choosing an appropriate GUI depends on the a...
Chapter 4 License Setup and Confirmation This chapter explains how to configure and confirm licenses. License Setup When using Resource Orchestrator, it is necessary to configure the license first. Use the following procedure to configure the license: 1. After logging in to Resource Orchestrator, se...
Chapter 5 Managing User Accounts This chapter explains how to register, modify, and delete user accounts. Add User Account Only privileged users can perform this operation. When using Single-Sign-On, register user information in ServerView Operations Manager beforehand. 1. From the ROR console menu,...
New password (Confirm password) Enter a string using up to 16 alphanumeric characters or symbols. Authority Level No change/Change Select the appropriate action.By default, the "No change" option is selected. Authority level Select either "Manage" or "Monitor".By default, the...
Chapter 6 BladeViewer This chapter provides an overview of BladeViewer and explains its features. Please note that BladeViewer is only available for PRIMERGY BX servers. For details on the ROR console, refer to " Appendix A User Interface ". 6.1 Overview This section provides a functional ov...
- Display of contact information BladeViewer allows users to define technical (support) contact information for their entire IT system. This contact information canbe shown by clicking on the Contact icon.Registering contact details of technical support staff beforehand can help streamline recovery ...
6.3.1 Status Panel The status panel displays a summary of resources statuses (including resources other than PRIMERGY BX servers). When a problem occurs in the system, a red or yellow light icon starts blinking on the left side of the status panel.Clicking the light icon changes its color back to gr...
Table 6.4 Chassis Icon Icon Meaning Chassis See For details on the different chassis statuses, refer to " Table 6.3 Status Icons " of " 6.3.1 Status Panel ". If a chassis icon shows a warning or error status, it means that a problem occurred in a resource contained in the chassis.For...
Figure 6.3 Blade Panel: Resource List Server Blade A power button is displayed in the upper-part of each server blade.This power button is used to represent the power status of each server, as shown below. Table 6.7 Server Blade Power Buttons Power button Color Status Meaning Green (lit) Power ON Po...
Table 6.8 Physical Server Icons Icon Meaning Server Spare server Unregistered server Maintenance mode server See For details on the different physical server statuses, refer to " Table 6.3 Status Icons " in " 6.3.1 Status Panel ". When a server blade is used as the admin server, the ...
- If the OS name cannot be acquired (because the OS has not been installed or for other reasons) The server name (physical server name or VM guest name) is displayed. The following table shows the resource icons used in BladeViewer and their associated meanings. Table 6.11 Resource Icons Icon Meanin...
Figure 6.4 Blade Panel: VM Guest List A VM guest icon is shown on the left side of each VM guest displayed in the VM guest list. Table 6.13 VM Guest Icon Icon Meaning VM guest See For details on the different VM guest statuses, refer to " Table 6.3 Status Icons " in " 6.3.1 Status Panel ...
Power button Color Status Meaning Orange (blinking) Power OFF inprogress Power OFF in progress. Information The power status of a VM guest can be easily controlled by clicking on its power button.Refer to " 6.4.2 VM Guest " for details. 6.3.4 Resource Details To view a resource's details, cl...
Power Off and Reboot Clicking on a power button that shows "Power ON" status will either shut down or reboot the target server blade. A [Power Operation]dialog is displayed, in which the appropriate action can be selected. Figure 6.5 Power Operation Dialog - "Shutdown" Selecting "...
Figure 6.6 Power Operation Dialog (with Additional Options) - "Force Shutdown" Selecting "Force Shutdown" will forcibly power off the target server blade. A confirmation dialog is displayed first.Clicking <OK> in the confirmation dialog will power off the managed server without...
Power button Color Status Action Green (lit) Power ON Shuts down or reboots a VM guest. Note - VM guests need to be properly configured in order to use the shut down or reboot buttons.Attempting to shut down or reboot a VM guest that is not properly configured will result in an error.For details, re...
Contact icon Displays the [Contact] dialog. This dialog shows the contact information that was set for the entire system. Tools icon Enables selection of the following menu options: Display Label List Displays the [Label List] dialog.Displays a list of labels. This list also allows modification of l...
Editing Labels and Comments This function is only available to privileged users.General users are only able to consult labels and comments. - Privileged user In the [Label List] dialog, select a server and click <Modify>. The [Modify Server Settings] dialog is displayed. The label and comment ...
Chapter 7 Registering Resources This chapter explains how to register, change, and delete resources used by Resource Orchestrator.The Resource Orchestrator manager must be completely installed beforehand. In addition to the usual method of registering each resource individually, it is also possible ...
Note HBA address rename and VIOM cannot be used together within the same chassis. When using backup and restore or cloning, prioritize the following two boot operations: 1. Boot from the first admin LAN network interface (NIC1 (Index1)) 2. Boot from the network interface used by the admin LAN (NIC2 ...
Password Enter the password for VM management software.Enter up to 128 characters, including alphanumeric characters and symbols (ASCII characters 0x20 to 0x7e). 3. Click <OK>. VM management software is registered with the entered information. Information Registration and management of multipl...
3. Click <OK>. The mounted chassis will be displayed under the server resource tree.Any server blade mounted within this chassis will be detected automatically and shown as: [ chassis_name- Slot_number[Unregistered]].The only operation available for those unregistered server blades is server r...
- LAN switch blade PY CB Eth Switch/IBP 1Gb 18/6 (3.12 or later version) 7.3.4 Configuring VLANs on LAN Switches On managed LAN switch blades, VLANs should be set on both internal ports (those connected to network interfaces on managed servers)and external ports (those connected to external, adjacen...
3. To use this feature, the following settings must first be defined: Port VLAN VLAN ID Enter the VLAN ID to assign to the LAN switch blade port that is connected to the network interface selected in step 2. Tagged VLAN VLAN ID Enter the tagged VLAN ID(s) to assign to the LAN switch blade port that ...
Figure 7.2 Status Transition Diagram for Managed Servers Use the following procedure to register rack mount or tower servers. 1. In the ROR console server resource tree, right-click [Server Resources], and select [Register]-[Server] from the popup menu. The [Register Server] dialog is displayed. 2. ...
7.4.2 Registering LAN Switches Use the following procedure to register LAN switches: 1. Discover LAN switches. For instructions, refer to " Discovery ". 2. Register LAN switches displayed in the network device tree. For instructions, refer to " Registration ". Discovery 1. From the R...
SNMP Community Enter the SNMP community that was set on this LAN switch.Either select [public] or enter an arbitrary string.Enter a string of up to 32 alphanumeric characters, underscores ("_"), and hyphens ("-"). 3. Click <OK>. The registered LAN switch will be displayed in th...
2. Define the following settings: WWNN Specify the WWNN value provided by the "I/O virtualization Option".The admin server generates WWPNs automatically from the values that are input into the WWNN and the number of HBAports. HBA ports Specify the following values according to the system con...
Figure 7.4 Procedures for Multi-path Configurations Example For a server with two ports, WWNs could be configured as follows. WWNN value provided by "I/O Virtualization Option": 20:00:00:17:42:51:00:00 Values to set in the [HBA address rename settings] dialog "WWNN" value 20:00:00:17...
The server restart is not required in other cases. The WWN that has been set is enabled at the next restart. 4. Click <OK>. Information When using a server without an OS, the resource name displayed on the server resource tree is the same as that of the physicalserver. 5. Restart the HBA addre...
Password Enter the password of the above remote server management user account.This password must be between 8 and 16 alphanumeric characters long. Note The [User ID] and [Password] of [Remote server management] are different from the user name and password used to log in onthe Web-UI for management...
Password Enter the password of the above ILOM user account.Enter between 8 and 16 characters, including alphanumeric characters, blank spaces (" "), and any of the following symbols."!", "@", "#", "$", "%", "^", "&", "*", ...
2. To use this feature, the following settings must first be defined: Device name Enter a name to assign to this power monitoring device. When exporting power consumption data, use this name to select powermonitoring devices for which to export data.Enter a character string beginning with an alphabe...
3. To use this feature, the following settings must first be defined: Subnet name Set the subnet name for registration.The name must start with an alphabetic character and can be up to 16 alphanumeric characters long (including underscores, "_",hyphens, "-", and periods, ".")...
# ln -s shared_disk local_disk <RETURN> Table 7.1 Files to Link Shared Disk Local Disk Mount_destination_of_shared_disk/Fujitsu/ROR/SVROR/etc/dhcpd.conf (*1) /etc/dhcpd.conf Mount_destination_of_shared_disk/Fujitsu/ROR/SVROR/etc/dhcp/dhcpd.conf (*2) /etc/dhcp/dhcpd.conf Mount_destination_of_sh...
11. Start cluster applications. Use the cluster system's operation management view (Cluster Admin) and start the manager cluster service (cluster application). 12. Register the admin LAN subnet. 7.9 Registering ETERNUS SF Storage Cruiser This section explains how to register ETERNUS SF Storage Cruis...
Chapter 8 Changing Admin Server Settings This chapter explains how to change the settings for the admin server. 8.1 Changing Admin IP Addresses Use the following procedure to change the IP address used on the admin LAN by the admin server. 1. Log on to the admin server with OS administrative privile...
8. Stop the agents on managed servers. [Windows] [Hyper-V] [Linux] [Xen] [KVM] Stop the agent referring to "2.2 Starting and Stopping the Agent" in the "Operation Guide VE". 9. Change Agent settings. [Windows] [Hyper-V] [Linux] [Xen] [KVM] Use the rcxadm agtctl modify command to set ...
Example When the takeover logical IP address is 192.168.4.100 before being changed ## DHCP Server Configuration file.# see /usr/share/doc/dhcp*/dhcpd.conf.sample#ddns-update-style none;option vendor-class-identifier "PXEClient";option dhcp-server-identifier 192.168.4.100 ; (*) subnet 192.168...
- Related Services - Deployment Service - TFTP Service - PXE Services - DHCP Server (*) [Linux Manager] - Manager Services - rcxmanager - rcxtaskmgr - rcxmongrel1 - rcxmongrel2 - rcxhttpd - rcxdb - Related Services - scwdepsvd - scwpxesvd - scwtftpd - dhcpd (*) * Note: Necessary when managing a mana...
# /opt/FJSVrcvmr/bin/rcxadm mgrctl modify -port name=number <RETURN> In a clustered manager configuration, bring offline all cluster resources except for the manager's shared disk and IP address, moveall cluster resources from the primary node to the secondary node, then execute the rcxadm mgr...
c. From the menu, select [Edit]-[Modify]. The [Edit DWORD Value] dialog is displayed. d. Select [Decimal] and click <OK>. This port value will define the first port of the range used by deployment services. However, because the related services can use up to 16 port numbers, ensure that all po...
8.4 Changing the Maximum Number of Cloning Image Versions Use the following procedure to change the maximum number of cloning image versions. 1. Change the maximum number of cloning image versions. 2. Check the maximum number of cloning image versions. For details of the methods for changing and che...
Chapter 9 Changing Resources This chapter explains how to change settings for the admin server or resources registered on the admin server. 9.1 Changing Chassis and Managed Server Settings This section explains how to change the settings for the chassis and managed servers.If collecting the system i...
2. In the ROR console server resource tree, right-click the target chassis and select [Modify]-[Registration Settings] from thepopup menu. The [Modify Chassis Settings] dialog is displayed. 3. Change [SNMP Community]. 4. Click <OK>. The SNMP community is changed. 9.1.5 Changing Server Manageme...
2. In the ROR console server resource tree, right-click the target chassis and select [Modify]-[Registration Settings] from thepopup menu. The [Modify Chassis Settings] dialog is displayed. 3. Select the [Modify remote server management login account] checkbox. Then, change the [User ID] and [Passwo...
1. In the ROR console server resource tree, right-click the target VM host, and select [Modify]-[VM Host Login Account] from thepopup menu. The [Change Login Information] dialog is displayed. 2. Enter the new login account information that was changed on the VM host. User ID Enter the user ID to log...
1. From the ROR console menu, select [Settings]-[Admin LAN Subnet]. The [Admin LAN Subnet] dialog is displayed. 2. Select the subnet to change. The [Change Admin LAN Subnet] dialog is displayed. 3. In the [Change Admin LAN Subnet] dialog, set the following items. Subnet name The name must start with...
When this setting is changed, the HBA address rename setup service automatically checks whether it can communicate with the new adminserver IP address.Changing this setting also requires changing the port on the admin server side beforehand. Change the IP address of the admin server according to ...
3. Click <OK>.To change registered VIOM server profiles, follow the procedure described in " 7.1.1 Registering VIOM Server Profiles " to open the Web interface of ServerView Virtual-IO Manager and change the settings. Changes made inside Virtual-IO Manager areautomatically reflected in...
Note - VLANs cannot be changed on PRIMERGY BX900/BX400 LAN switch blades operating in IBP mode. - If the port VLAN ID is unspecified or 1, a tagged VLAN ID cannot be set to 1. - When using End-Host Mode for the following LAN switch blades, cannot modify a port vlan id, and remove a tag vlan for the ...
- Deleting VLAN IDs from LAN switch ports Use the following procedure to delete VLAN IDs: 1. In the ROR console server resource tree, right-click the target LAN switch blade and select [Modify]-[Network Settings] fromthe popup menu. The [VLAN Settings] dialog is displayed. 2. To use this feature, th...
User ID Enter the user ID to use to control VM management software. Password Enter the password for VM management software. 3. Click <OK>. VM management software settings are changed. 9.6 Changing Power Monitoring Environment Settings This section explains how to change power monitoring enviro...
Use the following procedure to cancel the collection of power consumption data. 1. Select [Tools]-[Options] from the ROR console menu. The [Options] dialog is displayed. 2. Click the [Environmental Data] category title, and modify the values for the following items in the displayed area. Data to col...
2. Make changes to the values as needed. 3. Click <OK>. The settings for the monitoring information are changed to the entered settings. 9.7.2 Canceling Monitoring Information Settings This section explains how to cancel monitoring information settings. Use the following procedure to cancel th...
1. In the ROR console storage tree, right-click the target storage unit, and select [Modify]-[Registration Settings] from the displayedmenu. The [Resource Change Setting] dialog is displayed. 2. Modify the values for the following items: Label Enter up to 32 alphanumeric characters or symbols. Comme...
Chapter 10 Configuring the Operating Environments of Managed Servers This chapter explains how to install software to the registered managed servers and set up their operating environment. Figure 10.1 Procedure for Setting up Operating Environments *1: HBA address rename and VIOM cannot be used toge...
- If the target CA is not displayed, confirm the status of the following settings: - ESC is correctly registered on Resource Orchestrator. - Fibre Channel switches and storage units are correctly registered. - Only one access path is configured on ESC for each CA of an HBA. 10.2 Deploying Cloning Im...
Chapter 11 Deleting Resources This chapter explains how to delete resources.It is possible to register and delete a managed server and LAN switch as a single resource when they are in the same chassis.Note that operation of a server cannot be performed while the LAN switch is being registered and re...
Information - If HBA address rename has already been set up on the managed server, the HBA WWN is reset to the factory default.When this occurs, the managed server is turned on temporarily, after the power is forcibly turned off once.When the operating system is running on a managed server, it is re...
- Server blades that are managed using VIOM, and are currently the target of operations by Resource Orchestrator (power control,image-related processes, etc.) 11.4 Deleting LAN Switches This section explains how to delete LAN switches.There are two methods for LAN switch deletion, based on the LAN s...
Use the following procedure to delete power monitoring devices: 1. In the ROR console power monitoring devices tree, right-click the target power monitoring device and select [Delete] from thepopup menu. The [Delete Resource] dialog is displayed. 2. Click <OK>. The target power monitoring devi...
Chapter 12 Pre-configuration for Resource Registration and Modification This chapter provides an overview of the pre-configuration function and explains how to use system configuration files. 12.1 Overview Using the Pre-configuration function, it is possible to create system definition files that ca...
Note - The following operations cannot be performed by the pre-configuration function, and should be performed from the ROR console. - Deleting registered resources from Resource Orchestrator - Changing the name of a registered chassis, physical server (only for servers other than PRIMERGY BX server...
12.3 Exporting the System Configuration File This section explains the method for exporting a system configuration file containing the current system settings. Use the following procedure to export the system configuration file in CSV format from the ROR console. 1. Open and log in to the ROR consol...
Chapter 13 Network Map This chapter provides an overview of the Network Map and describes its features. 13.1 Overview The Network Map displays the following information for resources managed in Resource Orchestrator. - Network configuration of physical and virtual servers (including virtual switches...
Display filter area Provides checkboxes to select which information to display in the network view. Map navigation area Shows a zoomed-out version of the selected map (including items which are too far away to be displayed in the network view). VLAN display area Displays the selected VLAN ID in the ...
- NICs In addition, the following items will be displayed when the selected server is a VM host: - VM guests - Virtual switches - Ports - Network links - When selecting a LAN switch blade The following items are displayed: - Ports Selecting a LAN switch blade will show all its ports. For PRIMERGY BX...
Icon Meaning (*) LAN switch blade VM host VM guest Virtual switch LAN switch Port * Note: When operating in IBP mode Information If a problem occurs on a resource, a status icon indicating the problem is shown on top of the resource's own icon. For details on status icons, refer to " 13.4.1 Reso...
Icon Meaning Server VM host VM guest Switch VM switch 13.5 Network Links This section details the network links displayed in the Network Map. 13.5.1 Link Display The following table details the physical and virtual links displayed between resources. Table 13.12 Links Link Meaning Represents a physic...
Chapter 14 Power Control This chapter explains how to remotely control the power state of managed resources. 14.1 Server Power Control This section explains how to remotely control the power states of physical servers, VM hosts, and VM guests. Use the following procedure to perform power control ope...
[Windows] - Take caution regarding the following points when shutting down or rebooting a managed server running a Windows operating system. - If Windows is not configured to shut down when the computer's power button is pressed, the power operations in ResourceOrchestrator may not function properly...
Chapter 15 Control of VM Environments This chapter explains the Resource Orchestrator functions that are specific to VM guests and VM hosts.Some functions may or may not be available depending on the server virtualization software used. Refer to "D.1 Common Functions ofServer Virtualization Soft...
15.2 VM Maintenance Mode of VM Hosts This section explains how to set and release VM maintenance mode on VM hosts. For details on VM maintenance mode, refer to "D.3 Functional Differences between Products" in the "Design Guide VE".VM maintenance mode can also be set or released from ...
15.3.2 Migrating to VM Home Position Migrate VM guests back to their original VM hosts using the relationship information that was registered in advance. The method used for VM guest migration is automatically selected from cold migration and live migration after each VM guest's powerstatus is check...
15.4 External Software This section explains how to configure the settings required by Resource Orchestrator to interact with third party software. VM management console To launch an external VM management console (provided by the virtualization software used) from the ROR console, users must begran...
Chapter 16 Backup and Restore This chapter explains how to use the backup and restore functions provided in Resource Orchestrator. 16.1 Overview The backup and restore functions allow the backup and restoration of system images from physical OSs or VM hosts. The system image backup and restore funct...
> Installation_folder\SVROR\Manager\bin\rcxadm server set -name physical server -attr bootagt=dos <RETURN> [Linux Manager] #/opt/FJSVrcvmr/bin/rcxadm server set -name physical server -attr bootagt=dos <RETURN> - When using the Red Hat Enterprise Linux 6 ext4 file system, and one of th...
16.3 Restore This section explains how to restore a system image backup. System images can also be restored using commands.Refer to "Chapter 4 Image Operations" in the "Reference Guide (Command) VE" for details. Restoring a System Image Use the following procedure to restore a system...
16.4 Viewing This section explains how to browse and view existing system image backups. System images can also be listed using commands.Refer to "Chapter 4 Image Operations" in the "Reference Guide (Command) VE" for details. In the ROR console, select the [Image List] tab.The System...
Chapter 17 Cloning [Physical Servers] This chapter explains how to use the server cloning function. 17.1 Overview Cloning is a function used to deploy a cloning image collected from a single managed server (source server) to other managed servers(destination servers). This function shortens the time...
If the same server names are detected on the same network, a network duplication error will occur.Some programs may experience problems when started with a different hostname. If such programs have been installed, configuretheir services not to start automatically. This has to be configured before c...
"encrypted=yes" is added to indicate that the password is encrypted.For details, refer to "5.6 rcxadm deployctl" in the "Reference Guide (Command) VE". >" Installation_folder\Agent\bin\rcxadm" deployctl passwd -encrypt <RETURN> - With MAK (Already Encrypted P...
Deploying a Cloning Image Use the following procedure to deploy a cloning image to one or more destination servers: 1. Place the destination server(s) into maintenance mode (only for agent-registered servers). a. In the ROR console server resource tree, right-click the desired server (or its physica...
Figure 17.1 Cloning Image List For details on the "Cloning Image List", refer to " A.8 [Image List] Tab ". 17.5 Deleting This section explains how to delete a cloning image. Use the following procedure to delete cloning images: 1. In the ROR console, select the [Image List] tab. A li...
- When Using LAN Redundancy [Linux] - The "NIC switching mode (Physical IP address takeover function)" of PRIMECLUSTER Global Link Services Figure 17.2 Setup Procedure When Using the Network Parameter Auto-configuration Function Note [Physical Servers]The network parameter auto-configuration...
Table 17.3 Node Entry Settings Setting Keyword Expected Values: Description Managed servername NODE_NAME Physical servername Physical server name that was set whenregistering the managed server. Note Specify additional entries for any node (server) that may be added in the future (one entry per serv...
2. Enable the Network Parameter Auto-Configuration Function Enable the network parameter auto-configuration function by executing the following command.Execute this command from a managed server. [Windows] >" Installation_folder\Agent\bin\rcxadm" lanctl enable <RETURN> [Linux] # /op...
[Linux]/var/opt/FJSVnrmp/logs/error_lan.log For details on meanings of message and the appropriate corrective actions, refer to "Messages". The file size limit is 32 KB and only one version is maintained. Old logs will have the extension ".old" appended to the file name andremain in ...
Deploying New Managed Servers with Automated Public LAN Configuration Use the following procedure to add new managed servers and automate their public LAN settings using the network parameter auto-configuration function: 1. Register the newly added servers. 2. Perform the following procedure on a re...
Chapter 18 Server Switchover Settings This chapter explains how to use server switchover settings and automatically recover from server failures. 18.1 Status Display Current recovery settings can be confirmed by selecting a physical OS or VM host in the server resource tree of the ROR console andfro...
Note For servers other than those using I/O virtualization and those with WWN settings registered, the following checks will not be enabled. - [Power off forced when the server is switched over] checkbox - [Switchover to server where VM guest exists] checkbox [VM Host]The automatic startup of VM gue...
Chapter 19 Collecting Power Consumption Data and Displaying Graphs This chapter explains how to export the power consumption data collected from registered power monitoring targets and how to displayit as graphs, and also describes the exported data's format. 19.1 Exporting Power Consumption Data Th...
Target Resources Specify the power monitoring target to export the power consumption data of.Select the checkboxes of each desired target. More than one target can be selected. Data Type Specify the type of data to export.Check the checkbox of each desired data type. More than one data type can be s...
Rate Output time span Output device count Daily Last year 30 Monthly Select "Custom" and specify 5 years 60 Annual Select "Custom" and specify 5 years 60 19.2 Displaying Power Consumption Data Graphs This section explains how to display power consumption data as graphs. The power con...
3. Click <Graph Output>. After switching to the graph display window, the selected power consumption data can be displayed in line graphs. Figure 19.3 Graph Display Window The following operations can be performed from the graph display window. - Switching resource display By selecting and cle...
Appendix A User Interface Resource Orchestrator includes two graphical user interfaces: the ROR console and BladeViewer.This appendix provides an overview of the ROR console. For details on how to open and close the ROR console, refer to "Chapter 3 Login to the ROR Console" in the "Setup...
Popup Menu Function Menu Submenu Update - Updates a server. Modify Registration Settings Modifies a server's registration settings. HBA address rename settings (*2) Modifies the HBA address rename settings of a server. Network Settings (*3, *4) Modifies the network settings of a server. Spare Server...
Figure A.4 Tree Panel In the tree panel, clicking the area on the upper-left enables selection and display of the following 5 types of tree: server resources, networkdevices, power monitoring devices, management software, and VLAN. Server Resources Chassis, servers, physical OSs, VM hosts, VM guests...
Information For a VM host coordinated with VMware vCenter Server, the name (IP address or host name) entered when registering with VMwarevCenter Server will be displayed. network device External LAN switches (those other than LAN switch blades) managed in Resource Orchestrator are shown in a tree vi...
Figure A.5 Chassis The resource images shown in the above chassis image are explained in the table below. Table A.19 Meaning of the Resources Shown in the Chassis Image Image Meaning A. Registered server blade. B. Detected storage blade. C. Currently displayed server blade. D. Server blade selected ...
Collection Date The name used to identify a cloning image is displayed. OS The name of the operating system stored in the cloning image is displayed. Comments Comments describing the cloning image are displayed. Right-clicking a resource in the list displays a list of available operations in a popup...
Event Information Status Displays the level of the event.There are three levels: "Error", "Warning", or "Info". Date Date and time at which the event occurred. Resource Name Name of the resource associated with the event. Event ID Identifier related to the event.No event ID i...
Appendix B Format of CSV System Configuration Files This appendix explains the format of the CSV system configuration files used by Resource Orchestrator's pre-configuration function. B.1 Obtaining the System Configuration File (CSV Format) The system configuration files can be obtained as follows. ...
- change Modification - Hyphens, ("-") Do nothing - Parameter This describes the parameter value to be set. Note The order of operation and parameter columns should follow the order defined in section header under " B.3 Resource Definitions ". Allowed Characters For details on the ch...
Character Code The system configuration files (CSV format) used for pre-configuration are saved using ASCII (often referred to as "ANSI" in Windowssystems). When files that use a character code other than ASCII are imported, the system may not operate correctly.When directly editing configur...
login_passwd Enter the password of the above VIOM user account. passwd_enc Enter one of the following. - If login_passwd is plain text "plain" - If the password is encrypted "encrypted" Chassis Data - Section Name Enter [Chassis] as the section name. - Section Header operation Enter ...
Note Chassis names should be unique between all chassis.Names are not case-sensitive. ip_address Enter the same IP address as that configured on the XSCF.Enter a string of numeric values (between 0 and 255) and periods. Note IP addresses should be unique between all resources. snmp_community_name En...
- PY CB Eth Switch/IBP 10Gb 18/8 - BX600 GbE Switch Blade 30/12 - PRIMERGY BX600 GbE Switch 16/2x10Gb - PRIMERGY BX600 GbE Switch 16x1Gb - Cisco Catalyst Blade Switch 3040 connection_type Enter the connection method to use for the LAN switch blade.If you configure "ssh" for a LAN switch blad...
Server Management Information - Section Name Enter [Server] as the section name. - Section Header operation Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line. chassis_name Enter the chassis name (the value of "chassis_name" in the [Chassis] sect...
ipmi_ passwd_enc Enter one of the following. - If ipmi_passwd is plain text "plain" - If the password is encrypted "encrypted" admin_lan1_nic_number The index of the NIC to use for the admin LAN.Enter a number (1 or larger). Note This field is only required for PRIMERGY BX servers. a...
PRIMEQUEST Server Management Data - Section Name Enter [PRIMERGYPartitionModelServer] as the section name. - Section Header operation Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line. chassis_name Enter the chassis name (the value of "chassis_name&...
Note Server names should be unique between all servers.Names are not case-sensitive. ip_address Enter the same IP address as that set within the server's operating system.Enter a string of numeric values (between 0 and 255) and periods. Note IP addresses should be unique between all resources. HBA a...
spare_server Enter the physical server name of a server to be assigned as a spare server.To specify multiple spare servers, separate each server name using semicolons (";"). To remove current spare server settings, enter"-DELETE". vlan_switch (optional) Specify whether VLAN settings ...
product Enter the name of this VM management software. Enter one of the following. - When using VMware vCenter Server as VM management software. "vmware-vc" - When using System Center Virtual Machine Manager as VM management software. "ms-scvmm" login_name Enter the name of the user ...
vm_login_name Enter the name of the user account used to remotely log into the VM Host. vm_login_passwd Enter the password of the above user account (for remote login). vm_passwd_enc Enter one of the following. - If the password is plain text "plain" - If the password is encrypted "encry...
Power Monitoring Device Data - Section Name Enter [PowerDevice] as the section name. - Section Header operation Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line. device_name Enter the name that will be used to identify the power monitoring device.Enter...
Memo - Section Name Enter [Memo] as the section name.This is required when registering the labels, comments, and contact information (displayed in BladeViewer) using the pre-configurationfunction. - Section Header operation Enter the desired operation for the current line. Enter a hyphen ("-"...
Appendix C Maintenance Mode This appendix explains the maintenance mode available in Resource Orchestrator and how to use it. Maintenance mode is used during hardware maintenance of managed servers. It is also used during the installation and maintenance ofphysical OSs and VM hosts. Maintenance mode...
Glossary access path A logical path configured to enable access to storage volumes from servers. active mode The state where a managed server is performing operations.Managed servers must be in active mode in order to use Auto-Recovery.Move managed servers to maintenance mode in order to perform bac...
XSCF (eXtended System Control Facility) The name of the Remote Management Controller for SPARC Enterprise M series servers. zoning A function that provides security for Fibre Channels by grouping the Fibre Channel ports of a Fibre Channel switch into zones, andonly allowing access to ports inside th...
Fujitsu Manuals
-
Fujitsu P42VCA12
Manual
- Fujitsu S500M Manual
-
Fujitsu C1410
Manual
- Fujitsu FI-6140Z Manual
-
Fujitsu P50XHA40U
Manual
-
Fujitsu D1931
Manual
-
Fujitsu PDS5003W
Manual
-
Fujitsu M4099D
Manual
-
Fujitsu P63XHA40U
Manual
-
Fujitsu B6220
Manual
-
Fujitsu M3093DE
Manual
-
Fujitsu ETERNUS DX8000 series
Manual
-
Fujitsu FTP-641MCL352
Manual
-
Fujitsu YV2.4X2.5A-2
Manual
-
Fujitsu FS-1008MU
Manual
- Fujitsu T731 Manual
-
Fujitsu FTP-627MCL113
Manual
-
Fujitsu ETERNUS4000
Manual
-
Fujitsu FMWCC42
Manual
-
Fujitsu FTP-607 Series
Manual