Introduction Procedure Safety notes Preparation Main memory Accessible drives Controller in the PCI slots RemoteView components External SCSI interface Conversion standard PS to hot-plug PS Continued
U41604-Z156-1-76 Options Guide Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 1 1.2 Extensions and conversions . . . . . . . . . . . . . . . . . . . . 2 1.3 Notational conventions . . . . . . . ....
U41604-Z156-1-76 Options Guide 1 1 Introduction The PRIMERGY TX150 S3 Server is an Intel-based server for medium-sized networks and large companies. The server is suitable for use as a file server as well as an application, information, or Internet server. It is available as a floor-stand or rack mo...
2 Options Guide U41604-Z156-1-76 Extensions and conversions Introduction – The Technical Manual for the system board D1979 (PDF available on the ServerBooks CD supplied) – The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied) – The “PRIMERGY ServerView Suite - ServerStart” manual (p...
4 Options Guide U41604-Z156-1-76 Notational conventions Introduction Conversion standard power supply to hot-plug power supply The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules. If one power supply module fails, the o...
U41604-Z156-1-76 Options Guide 5 2 Procedure V CAUTION! The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper re...
U41604-Z156-1-76 Options Guide 7 3 Safety notes I The following safety notes are also provided in the “Safety” manual. This device complies with the relevant safety regulations for data processing equipment. If you have any questions about where you can set up the device, contact your sales outlet o...
8 Options Guide U41604-Z156-1-76 Safety notes Installation and operation V CAUTION! ● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requireme...
U41604-Z156-1-76 Options Guide 11 Safety notes Notes on handling CDs and CD-/DVD-ROM drives V CAUTION! ● Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries. ● Therefore, check each CD for damage, cracks, breakage etc. befo...
12 Options Guide U41604-Z156-1-76 Safety notes Modules with electrostatic-sensitive components: Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the fol...
U41604-Z156-1-76 Options Guide 13 4 Preparation V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . 4.1 Floorstand model 4.1.1 Opening the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off...
14 Options Guide U41604-Z156-1-76 Floorstand model Preparation 4.1.2 Removing the front cover Remove the front cover when making the following extensions and upgrades:– Installing further accessible drives – Upgrading the floorstand model to a rack model Ê Remove the hard disk cover as shown in figu...
U41604-Z156-1-76 Options Guide 15 Preparation Floorstand model 4.1.3 Removing the hard disk cover Remove the hard disk cover when making the following extensions and upgrades:– Installing fur ther SATA hard disk drives Ê Terminate all applications and shut down the server correctly. Ê If your operat...
16 Options Guide U41604-Z156-1-76 Rack model Preparation 4.2 Rack model Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off button. Ê Pull all power connectors out of the power outlets. 4.2.1 Opening the server...
U41604-Z156-1-76 Options Guide 17 Preparation Rack model Figure 7: Loosening the locking spring Ê Press in the locking spring (1) on both sides and carefully pull the server outward (2). Figure 8: Removing the server from the rack cabinet Ê Disconnect all cables on the rear of the server. Ê Remove t...
18 Options Guide U41604-Z156-1-76 Rack model Preparation V CAUTION! At least two people are needed to lift the server out of the rack cabinet. Ê Lift the server out of the rails and place it on a table, for example. Figure 9: Loosening the screws Ê Unlock the top cover by removing the two screws at ...
U41604-Z156-1-76 Options Guide 19 Preparation Rack model 4.2.2 Removing the rack front cover Remove the rack front cover when carrying out the following extension:– Installing fur ther accessible drives Figure 10: Removing the rack front cover Ê Remove two screws on either side (1). Ê Remove the rac...
U41604-Z156-1-76 Options Guide 21 5 Main memory V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . The system board supports up to 4 Gbytes of main memory. Four slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be equ...
22 Options Guide U41604-Z156-1-76 Extending/replacing the main memory Main memory The table below shows the order in which the memory banks must be equipped: 5.2 Extending/replacing the main memory Ê Open the server as described in the chapter “Preparation” on page 13 et seqq. . Figure 13: Removing ...
U41604-Z156-1-76 Options Guide 25 6 Accessible drives V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . Three 5.25-inch bays are available for accessible drives. The top side bay is already equipped with a CD/DVD-ROM drive. The two lower bays can also be u...
U41604-Z156-1-76 Options Guide 29 Accessible drives Installing the hard disks extension box 6.2 Installing the hard disks extension box In the SCSI version the two lower 5.25 inch bays for accessible drives can be used to install a HDD extension box. But it is required that the server is equipped wi...
U41604-Z156-1-76 Options Guide 31 7 Controller in the PCI slots V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32 Bit / 33 MHz) and 1 x PCI-Express x1 slot. The PCI slot 2 is p...
32 Options Guide U41604-Z156-1-76 Installing a controller Controller in the PCI slots 7.1 Installing a controller Ê Open the server as described in the chapter “Preparation” on page 13 et seqq. . Figure 23: Removing the rear cover Ê Swing the locking swivel in the direction of the arrow (1). Ê Press...
34 Options Guide U41604-Z156-1-76 PCI slot assembling Controller in the PCI slots 7.2 PCI slot assembling Install first those controllers which request a defined slot. Then install the PCI-X controllers, then the PCI66 and at least the PCI33 controllers. PCI bus type Quantity Preferred slot Forbidde...
U41604-Z156-1-76 Options Guide 35 8 RemoteView components V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . 8.1 RemoteView Service Board S2 LP I How to configure the RSB S2 LP is described in detail in the User Guide “RemoteView”. The preferred mounting lo...
U41604-Z156-1-76 Options Guide 37 RemoteView components RemoteView Service Board S2 LP Figure 27: Connecting external cables 1 connect to USB port of the server 2 connect to LAN port of the network 3 connect to VGA port of the server 4 connect to VGA port of the monitor RSB S2 LP Adapter Externe Str...
U41604-Z156-1-76 Options Guide 39 9 External SCSI interface V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . If the internal hard disks are connected via a PCI RAID controller, one channel of the on-board controller can also be made available for connecti...
42 Options Guide U41604-Z156-1-76 Conversion standard PS to hot-plug PS Figure 29: Loosening the screws Ê Remove the five screws (1) which attach the adapter plate of the standard power supply to the housing. Figure 30: Taking out the standard power supply Ê Slide the standard power supply somewhat ...
U41604-Z156-1-76 Options Guide 43 Conversion standard PS to hot-plug PS Figure 31: Installing the Power backplane in the PS cage Ê Inser t the Power backplane in the PS cage. Ê Push the Power backplane in direction of the arrows until the three bolts of the PS cage engage. Ê Fasten the Power backpla...
48 Options Guide U41604-Z156-1-76 Conversion standard PS to hot-plug PS Figure 36: Locking the power supply module Ê Push the green handle downward until the locking slide (see the arrow) engages. Ê Plug the power cord to the connector of the power supply module. Ê If you want to install a second po...
U41604-Z156-1-76 Options Guide 53 11 Converting from the floorstand model to the rack model V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . Ê Open the server and remove the front cover as described in the chapter “Preparation” on page 13ff. I The front c...
54 Options Guide U41604-Z156-1-76 Converting from the floorstand model to the rack model The right-hand side cover and the top cover build one part. Figure 41: Removing the screws Ê Remove the two screws at the rear side. Figure 42: Removing the right-hand side cover Ê Lift the hook up slightly usin...
U41604-Z156-1-76 Options Guide 55 Converting from the floorstand model to the rack model Ê Lay the server on its right-hand side. V CAUTION! Get a second person to help you do this. The server can weigh up to 40 kg. Figure 43: Removing the rubber feet Ê Remove the two upper rubber feet (see the arro...
U41604-Z156-1-76 Options Guide 57 Converting from the floorstand model to the rack model Ê Attach the rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 59ff. To enable the rack model to be presented correctly in Serv...
U41604-Z156-1-76 Options Guide 59 12 Completion V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. . 12.1 Floorstand model 12.1.1 Attaching the hard disk cover After you have installed further SATA hard disk drives, reattach the hard disk cover. Figure 45: At...
60 Options Guide U41604-Z156-1-76 Floorstand model Completion 12.1.2 Attaching the front cover After you have installed further accessible drives, reattach the front cover. Figure 46: Attaching the front cover Ê Press the two hooks (1) on the right side in the recesses of the housing. Ê Press the fr...
U41604-Z156-1-76 Options Guide 61 Completion Floorstand model 12.1.3 Closing the server Figure 47: Attaching the left-hand side cover Ê Position the left-hand side cover in such a way that it protrudes approxiate2 cm at the rear (1). Shut the left-hand side cover. Ê Push the left-hand side cover all...
62 Options Guide U41604-Z156-1-76 Rack model Completion 12.2 Rack model 12.2.1 Attaching the rack front cover Reattach the rack front cover after implementing the following extensions:– Installation of further accessible drives – Conversion of the floorstand model to a rack model Figure 49: Attachin...
U41604-Z156-1-76 Options Guide 63 Completion Rack model Figure 50: Attaching the rack front cover Ê Attach the rack front cover from the front (1). Ê Attach the rack front cover using two screws on each side (2). 2 2 1
U41604-Z156-1-76 Options Guide 65 Completion Rack model If you have not removed the server from the rack cabinet, please skip this page. V CAUTION! At least two people are required to install the server in the rack cabinet.Do not use the handles on the rack front cover to lift the server into the ra...
66 Options Guide U41604-Z156-1-76 Rack model Completion Figure 53: Fastening the server in the rack cabinet Ê Fasten the server in the rack using the four knurled screws (1). Ê Connect all power plugs to the power outlets. Ê Press the on/off key to star t up the server. 1
U41604-Z156-1-76 Options Guide 67 13 Appendix 13.1 Cabling I The Pn numbers of the power cables are identical for the standard and the redundant power supply. You will not find a special drawing for the power supply cabling. 13.1.1 SCSI version 1-channel SCSI version with onboard SCSI controller In ...
U41604-Z156-1-76 Options Guide 73 Abbreviations AC Alternating Current ANSI American National Standard Institut ASR&R Automatic Server Reconfiguration and Restar t BIOS Basic Input-Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD-ROM Compact Disk-Read Only ...
U41604-Z156-1-76 Options Guide 79 Related publications PRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the ServerView Suite delivered with each server system. The actual version of the necessary manuals can be downloaded free of charge from the Interne...
80 Options Guide U41604-Z156-1-76 Related Publications [14] Integrated Mirroring User’s Guide [15] Global Array Manager Client Software User’s Guide [16] Configurator For par tners and distributors only:http://extranet.fujitsu-siemens.com/cafe/products/primergy
U41604-Z156-1-76 Options Guide 81 Index Aaccessible drives 3, 25 Ccontroller 3, 32conversion of floorstand module to rack model 4 conversion standard power supply to hot-plug power supply 4 Conversion standard PS to hot-plug PS 41 EESD (devices sensitive to electrostatic discharge) 12 external SCSI ...
Comments on PRIMERGY TX150 S3 Server System U41604-Z156-1-76 Comments Suggestions Corrections ✁ Submitted by Fujitsu Siemens Computers GmbHUser Documentation81730 MünchenGermany Fax: (++49) 700 / 372 00000 email: [email protected]://manuals.fujitsu-siemens.com
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions. This document from the document archive refers to a product version which was released a considerable time ago or...
Fujitsu Manuals
-
Fujitsu P42VCA12
Manual
- Fujitsu S500M Manual
-
Fujitsu C1410
Manual
- Fujitsu FI-6140Z Manual
-
Fujitsu P50XHA40U
Manual
-
Fujitsu D1931
Manual
-
Fujitsu PDS5003W
Manual
-
Fujitsu M4099D
Manual
-
Fujitsu P63XHA40U
Manual
-
Fujitsu B6220
Manual
-
Fujitsu M3093DE
Manual
-
Fujitsu ETERNUS DX8000 series
Manual
-
Fujitsu FTP-641MCL352
Manual
-
Fujitsu YV2.4X2.5A-2
Manual
-
Fujitsu FS-1008MU
Manual
- Fujitsu T731 Manual
-
Fujitsu FTP-627MCL113
Manual
-
Fujitsu ETERNUS4000
Manual
-
Fujitsu FMWCC42
Manual
-
Fujitsu FTP-607 Series
Manual