Page 2 - Copyright and Trademarks
Comments … Suggestions … Corrections … The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to [email protected] . Certified documentation acc...
Page 3 - Operating Manual; Contents
RX200 S5 Operating Manual Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 5 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 5 1.3 Expansions and conversions . . . . . . . . . . . ....
Page 5 - Options Guide; Preface; The server occupies one height unit in the rack.; Concept and target groups; This Options Guide shows you how to extend and upgrade your server.; Documentation overview; “Safety notes and other impor tant information” manual
RX200 S5 Options Guide 5 1 Preface The PRIMERGY RX200 S5 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server. Thanks to its highly developed hardware and software compone...
Page 6 - Industry standard servers; Further sources of information:
6 Options Guide RX200 S5 Documentation overview Preface © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 09 8-0 0 1 .f m – “Warranty” manual – “PRIMERGY ServerV...
Page 7 - Expansions and conversions
RX200 S5 Options Guide 7 Preface Expansions and conversions 1.3 Expansions and conversions Second processor The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first...
Page 8 - TPM
8 Options Guide RX200 S5 Expansions and conversions Preface © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 09 8-0 0 1 .f m TPM A Trusted Platform Module (TPM)...
Page 9 - Notational conventions; Text in italics
RX200 S5 Options Guide 9 Preface Notational conventions 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items. “Quotation marks” indicate names of chapters and terms that are being emphasized. Ê describes activities ...
Page 11 - Procedure; First of all, carefully read the safety instructions in the
RX200 S5 Options Guide 11 2 Procedure V CAUTION! ● The actions described in this manual should only be performed by technical specialists. ● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the sy...
Page 13 - Safety instructions
RX200 S5 Options Guide 13 3 Safety instructions I The following safety instructions are also provided in the manual “Safety notes and other impor tant information”. This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server ...
Page 14 - Before starting up
14 Options Guide RX200 S5 Safety instructions © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 0-0 0 1 .f m Before starting up V CAUTION! ● During installati...
Page 16 - Batteries
16 Options Guide RX200 S5 Safety instructions © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 0-0 0 1 .f m V CAUTION! ● Proper operation of the system (in a...
Page 17 - Laser information
RX200 S5 Options Guide 17 Safety instructions Working with CDs/DVDs and CD/DVD drives When working with devices with CD/DVD drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipmen...
Page 18 - Modules with electrostatic-sensitive components; The equipment and tools you use must be free of static charges.
18 Options Guide RX200 S5 Safety instructions © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 0-0 0 1 .f m Modules with electrostatic-sensitive components S...
Page 19 - Preparation; Follow the safety instructions in the chapter; Pulling out/removing the server; Terminate all applications and shut down the server correctly.; At least two people are needed to remove the server from the rack.
RX200 S5 Options Guide 19 4 Preparation V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . 4.1 Pulling out/removing the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press t...
Page 20 - Opening the server; You must remove the fan cover before removing the housing cover.; Removing the fan cover; Removing the housing cover
20 Options Guide RX200 S5 Opening the server Preparation © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 1-0 0 1 .f m 4.2 Opening the server You must remove...
Page 21 - Lift off the housing cover upwards.
RX200 S5 Options Guide 21 Preparation Opening the server Figure 4: Using the locking levers Ê Push the green locking levers together as shown (1) and then move them up (2) so that the housing cover is pushed backward slightly. Ê Lift off the housing cover upwards.
Page 22 - Removing the air cowl; Lift the air cowl upwards to remove it.
22 Options Guide RX200 S5 Removing the air cowl Preparation © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 1-0 0 1 .f m 4.3 Removing the air cowl Figure 5:...
Page 23 - Processors; “Safety instructions” on; Installing a second processor; chapter “Preparation” on page 19
RX200 S5 Options Guide 23 5 Processors V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . V CAUTION! Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a proces...
Page 24 - Inserting the processor
24 Options Guide RX200 S5 Installing a second processor Processors © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 2-0 0 1 .f m Inserting the processor Figu...
Page 25 - Place the heat sink on the processor as shown.
RX200 S5 Options Guide 25 Processors Installing a second processor Installing the heat sink Figure 8: Installing the heat sink Ê Place the heat sink on the processor as shown. Ê Fasten the heat sink by tightening the four screws in a crossover pattern (see circles). V CAUTION! Never install a proces...
Page 26 - Replacing the processor
26 Options Guide RX200 S5 Replacing the processor Processors © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 2-0 0 1 .f m 5.2 Replacing the processor V CAUT...
Page 27 - Lift the installed processor carefully out of the socket (3).
RX200 S5 Options Guide 27 Processors Replacing the processor Figure 10: Removing an old processor Ê Release the socket lever by pressing it sideways and pull it upward as far as it will go (1). Ê Open the cover (2). Ê Lift the installed processor carefully out of the socket (3). Figure 11: Inserting...
Page 29 - Replacing the heat sink
RX200 S5 Options Guide 29 Processors Replacing the heat sink 5.3 Replacing the heat sink Ê Open the server as described in chapter “Preparation” on page 19 . Ê Lift the air cowl upwards to remove it as described in section “Removing the air cowl” on page 22 . Ê Remove the four screws of the heat sin...
Page 31 - Main memory
RX200 S5 Options Guide 31 6 Main memory V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . The system board has a total of 12 slots (6 for each CPU) for memory modules (DIMMs), which are suitable for both RDIMM memory modules (registered DIMM with the capacit...
Page 32 - Main memory; Equipping rules; Independent Channel Mode; Allows all channels to be equipped in any order.; Mirrored Channel Mode; RDIMM memory modules are suppor ted.
32 Options Guide RX200 S5 Equipping rules Main memory © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 3-0 0 1 .f m 6.1 Equipping rules The 6 slots for each ...
Page 33 - Spare Channel Mode; RDIMM memory modules are supported.; Notes on equipping; Equipping always star ts at DIMM slot 1A.
RX200 S5 Options Guide 33 Main memory Equipping rules Performance Channel Mode – Requires identical modules on all channels of each bank for each CPU. – RDIMM memory modules are supported. Spare Channel Mode – Requires identical modules on all channels of each bank for each CPU. – One-third of the c...
Page 34 - Extending/replacing the main memory; Open the server as described in; Removing installed memory modules
34 Options Guide RX200 S5 Extending/replacing the main memory Main memory © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 3-0 0 1 .f m 6.2 Extending/replaci...
Page 35 - Fit the air cowl as described in
RX200 S5 Options Guide 35 Main memory Extending/replacing the main memory Inserting memory modules Figure 14: Inserting a memory module Ê Inser t the memory module into the slot (1) and carefully press it down until the ejection levers on the sides engage (2). Ê Fit the air cowl as described in chap...
Page 37 - Accessible drive
RX200 S5 Options Guide 37 7 Accessible drive V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . Inser t the optical drive that can be delivered as an option in a mounting frame before sliding it in the server. The par ts required for the installation are show...
Page 38 - Installing a SATA DVD drive; section “Cable diagrams” on page 68
38 Options Guide RX200 S5 Installing a SATA DVD drive Accessible drive © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 4-0 0 1 .f m 7.1 Installing a SATA DV...
Page 39 - Push the DVD drive into the slot from the outside until it engages.
RX200 S5 Options Guide 39 Accessible drive Installing a SATA DVD drive Figure 17: Position of the pins in the mounting frame and the openings on the DVD drive Ê Inser t the DVD drive into the mounting frame so that the plastic pins (1) on both sides of the mounting frame are inser ted into the openi...
Page 41 - HDD modules
RX200 S5 Options Guide 41 8 HDD modules V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . The server can accommodate two further hard disk drive modules (HDDs) instead of the DVD drive. To do this, you need a conversion kit consisting of the following parts:...
Page 42 - Removing an existing DVD drive or dummy module
42 Options Guide RX200 S5 HDD modules © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 5-0 0 1 .f m Removing an existing DVD drive or dummy module Ê Disconne...
Page 43 - Removing the DVD drive cage
RX200 S5 Options Guide 43 HDD modules Removing the DVD drive cage Figure 21: Demounting the DVD drive cage Ê Loosen the screw on the right hand side (see circle) and move the DVD drive cage outwards in the direction of the arrow.
Page 44 - Removing the existing backplane (6x HDD); Remove all HDD modules from the housing.; Install HDD backplanes in the reverse order.
44 Options Guide RX200 S5 HDD modules © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 5-0 0 1 .f m Removing the existing backplane (6x HDD) Ê Remove all HDD...
Page 45 - Installing the drive cage for 8x HDD
RX200 S5 Options Guide 45 HDD modules Installing the drive cage for 8x HDD Figure 23: Installing the HDD drive cage Ê Push the drive cage for the two additional HDD modules into the housing. Ê Screw the drive cage in place (see circle).
Page 46 - Inserting the HDD modules; chapter “Completion” on page 61
46 Options Guide RX200 S5 HDD modules © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 5-0 0 1 .f m Inserting the HDD modules Figure 24: Installation positio...
Page 47 - Expansion cards and iBBU; Installing an expansion card in riser cards; slots can be equipped as follows:
RX200 S5 Options Guide 47 9 Expansion cards and iBBU V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . 9.1 Installing an expansion card in riser cards The server has three slots for PCIe expansion cards. These are integrated in the system using riser cards (...
Page 48 - Removing the riser card holders; Pull the required riser card holder upwards to remove it.; Installing an expansion card; Please read the documentation supplied with the expansion card.
48 Options Guide RX200 S5 Installing an expansion card in riser cards Expansion cards and iBBU © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 6-0 0 1 .f m ...
Page 49 - Keep the rear cover for future use.
RX200 S5 Options Guide 49 Expansion cards and iBBU Installing an expansion card in riser cards Figure 26: Riser card holder #2 with riser card Ê Remove the rear cover (1) from the riser card holder. I Keep the rear cover for future use. If you remove the expansion card, you must replace the rear cov...
Page 50 - Inser t the board into the riser card holder of the same height.; Reinstalling the riser card holders
50 Options Guide RX200 S5 Installing an expansion card in riser cards Expansion cards and iBBU © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 6-0 0 1 .f m ...
Page 51 - Installing a modular RAID controller; Removing riser card holder #3; Please read the documentation supplied with the RAID controller.; Carefully push the RAID controller into the slot of riser #3.; Installing the riser card holder
RX200 S5 Options Guide 51 Expansion cards and iBBU Installing a modular RAID controller 9.2 Installing a modular RAID controller A modular RAID controller can be installed in the server as an option. Riser card holder #3 (see figure 25 on page 48 ) is intended solely for this purpose. Removing riser...
Page 52 - Installing an iBBU
52 Options Guide RX200 S5 Installing an iBBU Expansion cards and iBBU © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 6-0 0 1 .f m Ê Close the server, conne...
Page 54 - Install the iBBU in its holder in the server as follows:
54 Options Guide RX200 S5 Installing an iBBU Expansion cards and iBBU © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 10 6-0 0 1 .f m Figure 32: Installing the...
Page 55 - Route the iBBU cable as shown.
RX200 S5 Options Guide 55 Expansion cards and iBBU Installing an iBBU Figure 33: iBBU - Routing the cable Ê Route the iBBU cable as shown. I The iBBU cable must pass beneath the power cable that crosses the iBBU cable.
Page 57 - Inser t the uSSD in its slot (see circle) and screw it in place.
RX200 S5 Options Guide 57 10 USB solid state disk (uSSD) V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . The system board has a slot – possibly covered by an installed modular RAID controller – for a USB solid state disk (uSSD). It can be used as optional ...
Page 61 - Completion; Fitting the air cowl; Refit the air cowl. Please note the information described below.
RX200 S5 Options Guide 61 12 Completion V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13 . 12.1 Fitting the air cowl Figure 37: Fitting the air cowl Ê Refit the air cowl. Please note the information described below.
Page 65 - Closing the server; Make sure that each bolt is positioned in the corresponding nut.; At least two people are needed to position the server in the rack.
RX200 S5 Options Guide 65 Completion Closing the server 12.2 Closing the server Ê Position the housing cover so that it protrudes about 1 cm over the back edge. Make sure that each bolt is positioned in the corresponding nut. Ê Push the housing cover all the way forward until it clicks into place. Ê...
Page 67 - Cabling; Cabling overview; Description
RX200 S5 Options Guide 67 13 Cabling 13.1 Cabling overview No. Part no. Description From To 1 A3C40102683 Front VGA cable Front panel board System board 2 A3C40102687 SATA cable ODD Optical Disk Drive (ODD) 1. SATA connection (system board) 2. HDD backplane 3 A3C40102656 SAS HDD cable Onboard SATA c...
Page 68 - Cable diagrams
68 Options Guide RX200 S5 Cable diagrams Cabling © c ogn it as . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n tat ion m b H 20 09 P fa d : W :\ A nw en dun gs da te n\ F C T \t im _ lo c a l\ w o rk \P IC H O L \O B J _ DO K U -4 11 0-0 0 1 .f m 13.2 Cable diagrams 13.2.1 Cabling for up to 4...
Page 71 - Index
RX200 S5 Options Guide 71 Index 5.25 inch DVD bay 7 A Accessible drives 7 air cowl fitting 61 removing 22 C Chipkill 31 components hardware 5 software 5 D data manipulation 5 drive cage (8x HDD) 45 DVD drive 38 E ESD (devices sensitive to electrostatic discharge) 18 expansion cards 7 , 48 , 51 H HDD...