Page 3 - Revision History; Rev Date Remark
AN706-00044-1v0-E Revision History Rev Date Remark 1.0 Jul. 14, 2011 First Edition 2
Page 4 - Table of Contents
AN706-00044-1v0-E Table of Contents Revision History .................................................................................................................... 2 Table of Contents ...............................................................................................................
Page 5 - Introduction; In Chapter 2, it explains system requirements for the GUI software.
AN706-00044-1v0-E 1 Introduction This user manual describes how to use FUJITSU’S FM3 Inverter Platform GUI. In Chapter 2, it explains system requirements for the GUI software. In Chapter 3, it explains how to install the GUI software. In Chapter 4, it explains how to install the communication driver...
Page 6 - System requirements
AN706-00044-1v0-E 2 System requirements The GUI software supported environment on PC 2.1 Supported Operating Systems: Windows Server 2003, Windows Server 2008, Windows Vista, Windows XP, Windows 7 1. Microsoft Windows XP Service Pack 2 or Service Pack 3 Minimum of 192 MB of RAM (384 MB preferred) At...
Page 7 - Install GUI; Install the GUI software in your PC
AN706-00044-1v0-E 3 Install GUI Install the GUI software in your PC This FUJITSU’S FM3 Inverter Platform GUI is given by compressed file, please copy and unzip the “FUJITSU’S FM3 Inverter platform GUI.zip” file to your PC. Then, you will find 10 files in the “FUJITSU’S FM3 Inverter platform GUI” fol...
Page 8 - Simply install steps about the communication Driver
AN706-00044-1v0-E 4 Simply install steps about the communication Driver A simply install steps for the FTDI. 4.1 To install FTDI driver in Windows XP Simply install steps: 1. Connect the FTDI device (board) to a USB port on the PC. 2. New Hardware Wizard will launch. 3. Select "Install from a li...
Page 9 - How to use the GUI; Introduce the GUI software
AN706-00044-1v0-E 5 How to use the GUI Introduce the GUI software 5.1 Overview This GUI use to cooperate with the FUJITSU’S FM3 inverter platform, customer can use this GUI to: 1. Real-time control the motor and PFC module function; 2. Real-time setting the motor functions and parameters; 3. Real-ti...
Page 10 - Open the folder double click the “; ARMInverterPlatform.exe; ” to run the software, as Figure
AN706-00044-1v0-E 5.3 GUI Startup Open the folder; double click the “ ARMInverterPlatform.exe ” to run the software, as Figure 5.2. Figure 5-2: GUI files 9
Page 12 - Name of button
AN706-00044-1v0-E 5.4.2 Main window - Name : Main window - Function: connect control, start/stop control, function/parameter setting, Constant/variable observation, language setting, and current state. Figure 5-4: main window Table 5-1: main window function Name of button Specification 1 Connect Ini...
Page 21 - - Wave save and load function are not prepared.
AN706-00044-1v0-E Table 5-4: wave observer function Name of area Description 1 Form name Custom the name of this wave window. 2 Show wave Draw the wave of signal needing to show. 3 Waveform name Shown the waveform name, it’s come from select signal 4 Select signal Select the signal to show the wave ...
Page 24 - window; Name; variable observation window.
AN706-00044-1v0-E 5.4.6 Variable window - Name : variable observation window. - Function: show the signal value, select signal. 2 1 Figure 5-8: variable observation window Table 5-5: variable observation function Name of area Specification 1 Variable value Show the value form hardw...
Page 26 - Connect
AN706-00044-1v0-E 5.5 Example of total operating Procedure This chapter introduces the operating method of GUI. 5.5.1 Hardware preparation Before operating GUI, prepare hardware according to the following procedure. 1. Install the FTDI driver (Only once) 2. Prepare the hardware environment 3. Connec...
Page 28 - Compressor Start-stop Control; button in Main Window to start the; Compressor Start-stop; button changes from green to red. The button text changes from; Run; to; Stop
AN706-00044-1v0-E (2) Start running the motor Next, click Compressor Start-stop Control button in Main Window to start the motor (1 in the Figure 5-11 ). If succeeds, the color of Compressor Start-stop Control button changes from green to red. The button text changes from Run to Stop . 1 Figure 5-11...
Page 31 - To display the waveform, click; button in Main Window (1 in; Graphic; Window in
AN706-00044-1v0-E (4) Show the wave To display the waveform, click Graphic button in Main Window (1 in Figure 5-14 ), and the Graphic Window in Figure 5-15 is displayed. 1 Figure 5-14: operation: open the wave window 30
Page 35 - Appendix; Particular Install steps about the communication Driver
AN706-00044-1v0-E 6 Appendix 6.1 Particular Install steps about the communication Driver 6.1.1 To install FTDI device in Windows XP - Copy and unzip the FTDI driver on the PC. - Connect the device to spare USB port on the PC. If the device is based on the FT2232, the Microsoft composite device drive...
Page 42 - the FT2232, two ports will be available from a composite USB device.
AN706-00044-1v0-E - Open the Device Manager (located in "Control Panel¥System" then select the "Hardware" tab and click "Device Manger") and select "View > Devices by Connection", the device appears as a "USB Serial Converter" with an additional COM port wi...
Page 44 - t the next screen select Device Manager:
AN706-00044-1v0-E Figure 6-16 - t the next screen select Device Manager: Figure 6-17 - In the Device Manager window there will be a device under Other Devices with a A yellow warning symbol to indicate a problem ie no driver installed. The text next to this device will depend on the device attached....
Page 45 - option for an automatic search or a manual search.
AN706-00044-1v0-E Figure 6-18 - Right click on the other device (TTL232R in this example) to bring up a menu as shown below. Figure 6-19 From the displayed menu select “Update Driver Software…” This then displays the option for an automatic search or a manual search. 44
Page 52 - - Select the second option to browse manually.
AN706-00044-1v0-E Figure 6-26 - Select the second option to browse manually. Figure 6-27 51
Page 53 - - After entering the address select “NEXT” to start the installation.
AN706-00044-1v0-E In the address box put the exact location where the drivers have been saved to. This may be on a CD or in a folder on the PC. It is not necessarily the exact same location as shown in the screenshot. The drivers could have been saved anywhere of the users choosing. - After entering...
Page 56 - Motor parameter item
AN706-00044-1v0-E 55 6.2 Motor parameter item Table 6-1: motor parameter Motor parameter name Unit Init Value compressor model - DA89 pole pairs Pole pairs 2 Ld mh 8.8 Lq mh 14.4 target rotational speed Hz 30 target Speed RPM 1800 KP for Id ( KD ) - 0.8 KI for Id ( ID ) - 0.01 KP for Iq ( KQ ) - 0.8...