Preface Purpose This manual describes how to install the Gigabit Ethernet card into your SPARC Enterprise system, and configure the environmentalsettings for the interface. Target Reader This manual is intended for system administrators responsible for installing the Gigabit Ethernet card. To unders...
Note - This symbol indicates that important information is given. Information - This symbol indicates that useful information is given. Handling of This Manual This manual contains important information regarding the use and handling of this product. Read this manual thoroughly. Pay specialattention...
Contents Chapter 1 Product Outline ........................................................................................................................................................1 1.1 Key Features .................................................................................................
Chapter 1 Product Outline This chapter describes the following topics. - 1.1 Key Features - 1.2 Gigabit Ethernet Card Specifications 1.1 Key Features The Gigabit Ethernet cards covered in this manual are adapters designed for Solaris servers that are connected to a Gigabit Ethernetnetwork. These car...
The GLDv3 compliant driver works with the following features. - The LinkAggregation (based on IEEE 802.3) by the dladm(1M) command. - Solaris Containers (Exclusive-IP Non-Global Zones) - Oracle VM Server for SPARC The GLDv3 compliant driver does not work with the following features. - SNA/FNA - The ...
Item Hardware Specification Power Requirements Maximum: 9.1W (SE0X7GD1X), 9.2W (SE0X7GD2X),15.0W (SE0X7GQ1X), 12.8W (SE0X7GQ2X) Connections 1000Base-SX (SE0X7GD2X): Multi-mode Fibre LC-SC: 62.5/125 micron and 50/125micron (Card side is LC. Used when connecting to a device with an SC connector.), LC-...
Chapter 2 Gigabit Ethernet Card Installation This chapter describes the tasks necessary to install this card in your system.Install the hardware with the following procedures. - 2.1 Installation of the Gigabit Ethernet Card - 2.2 Identifying the Gigabit Ethernet Card - 2.3 Cable Connection 2.1 Insta...
Chapter 3 Setting Instructions This chapter describes the summary of environment settings required after installing this product.Install the driver and configure environment settings using the following procedures. - 3.1 Driver Software Installation - 3.2 Identification of Interface Name - 3.2 Ident...
3.3 Environment Setting This section explains how to edit the necessary files and use the commands(Solari 11 only) to configure the operating environment foreach FUJITSU PCI GigabitEthernet interface. For TCP/IP (IPv4 or IPv6), edit the following files and execute the following command(Solaris 11 on...
3.3.2 Environment Setting of IPv6 Interfaces - Solaris 10 8/07 or later 1. Edit the /etc/hostname6. fjgi* file Assign an IPv6 address or hostname and prefix length to the fjgi interface by editing the /etc/hostname6.fjgi* file (where fjgi* represents the driver name and instance number). Example of ...
Information - The following example shows how to display an IP address and prefix length that assigned the fjgi interface. Example: When setting an IP address (example: 192.168.150.1) and prefix length (example: 24) to fjgi interface (example: fjgi0 (thisvanity name is net2)). # ipadm show-addr net2...
FJSV,e2ta, instance #6 (driver name: fjgi) FJSV,e2ta, instance #7 (driver name: fjgi) FJSV,e4tb, instance #8 (driver name: fjgi) FJSV,e4tb, instance #9 (driver name: fjgi) FJSV,e4tb, instance #10 (driver name: fjgi) FJSV,e4tb, instance #11 (driver name: fjgi) The installed Gigabit Ethernet card type...
Logical bus address Instance number Driver name "/pci@1,700000/pci@0,1/FJSV,e4ta@6,1" 3 fjgi "/pci@3,700000/pci@0/FJSV,e2sa@4" 4 fjgi "/pci@3,700000/pci@0/FJSV,e2sa@4,1" 5 fjgi "/pci@2,600000/pci@0/FJSV,e2ta@4" 6 fjgi "/pci@2,600000/pci@0/FJSV,e2ta@4,1" 7 fjgi...
- How to Return to Default FCode Settings (Auto-Negotiation Mode): - To return to default FCode settings, execute the following command from the ok prompt, or power cycle the system. ok reset-all 3.6 Network Installation See the document " Install Server Build Guide I/O Device Driver (SPARC Ente...
The FUJITSU PCI GigabitEthernet 4.1 or later drivers support: Supported VIDs 1 - 4094 Max number of VLAN interfaces 1024 3.7.2 Setting Up the VLAN Interface The VLAN interface is set up using the following procedures. - By setting the interface number to 1000 or greater, it is possible to distinguis...
Chapter 4 LinkAggregation Feature This chapter outlines the LinkAggregation feature, and explains the settings required to use this feature. - 4.1 About LinkAggregation Feature - 4.2 Configuration of the LinkAggregation Feature - 4.3 Notes 4.1 About LinkAggregation Feature This section explains the ...
- LAN switch that supports the LinkAggregation (or equivalent) feature - Data Distribution Mode " Table 4.2 Data Distribution Mode " shows data distribution modes that FUJITSU Gigabit Ethernet 4.1 or later supports. Table 4.2 Data Distribution Mode L2 distribution The driver decides on the d...
This mode is used for re-configuring the LinkAggregation Group of thepartner device automatically when the configuration of theLinkAggregation Group of the local device is changed. Also, the driverdoes not need to transmit the LACP for cases when the local devicefunctions as a router, or the partner...
Chapter 5 Troubleshooting The following should be checked first to troubleshoot a problem. Is the driver software installed correctly? If the "pkginfo -x FJSVgid" command does not return output, the driver package is not installed. If this occurs, install the driver packageusing the driver C...
Appendix A Messages This chapter explains messages displayed by the FUJITSU PCI GigabitEthernet driver. A.1 Console Messages from the Driver Messages from the FUJITSU PCI GigabitEthernet driver are listed in the following table. Table A.1 Console Messages(NOTICE) from the FUJITSU PCI GigabitEthernet...
Table A.4 Messages Reported by Machine Administration No Message Meaning Workaround 1 fjgi_device_check: fjgi_hw_deinit failed ! An error occurred duringinitialization of the adapter. The version number of the driver may notsupport this hardware. Please apply anyapplicable patches described in theIn...
Appendix B Gigabit Ethernet Card LED Diagnosis This appendix explains the LED diagnosis function of Gigabit Ethernet cards. B.1 Location and Meaning of the LEDs - Location of the LEDs (SE0X7GD2X) The following figure shows the location of the LEDs on SE0X7GD2X. Figure B.1 1000Base-SX * 2ports (SE0X7...
Appendix C Using FUJITSU PCI GigabitEthernet in a Cluster Environment This Appendix outlines the supported functions and setup procedure for the FUJITSU PCI GigabitEthernet 4.1 or later or the FUJITSUPCI GigabitEthernet 5.0 or later interface when used in a cluster environment (PRIMECLUSTER). C.1 Cl...
Appendix D Using FUJITSU PCI GigabitEthernet in Solaris Containers This Appendix outlines the supported functions and setup procedure for the FUJITSU PCI GigabitEthernet 4.1 or later or the FUJITSUPCI GigabitEthernet 5.0 or later interface when used in Solaris Containers. D.1 Solaris Containers Supp...
Appendix E Using FUJITSU PCI GigabitEthernet in Oracle VM Server for SPARC This Appendix outlines the supported functions and setup procedure for the FUJITSU PCI GigabitEthernet 4.1 or later or the FUJITSUPCI GigabitEthernet 5.0 or later interface when used in Oracle VM Server for SPARC. E.1 Oracle ...
Appendix F Using FUJITSU PCI GigabitEthernet in Solaris 11 Network Virtualization This Appendix outlines the supported functions and setup procedure for the FUJITSU PCI GigabitEthernet 5.0 or later interface whenused in Solaris 11 Network Virtualization. F.1 Solaris 11 Network Virtualization Support...
Appendix G PCI Slot Number and Device Name This appendix provides a cross-reference of PCI slot numbers and device names for the following SPARC Enterprise models. - - SPARC Enterprise M3000 - - SPARC Enterprise M4000/M5000 - - SPARC Enterprise M8000/M9000 - - SPARC Enterprise T1000 - - SPARC Enterp...
Fujitsu Manuals
-
Fujitsu P42VCA12
Manual
- Fujitsu S500M Manual
-
Fujitsu C1410
Manual
- Fujitsu FI-6140Z Manual
-
Fujitsu P50XHA40U
Manual
-
Fujitsu D1931
Manual
-
Fujitsu PDS5003W
Manual
-
Fujitsu M4099D
Manual
-
Fujitsu P63XHA40U
Manual
-
Fujitsu B6220
Manual
-
Fujitsu M3093DE
Manual
-
Fujitsu ETERNUS DX8000 series
Manual
-
Fujitsu FTP-641MCL352
Manual
-
Fujitsu YV2.4X2.5A-2
Manual
-
Fujitsu FS-1008MU
Manual
- Fujitsu T731 Manual
-
Fujitsu FTP-627MCL113
Manual
-
Fujitsu ETERNUS4000
Manual
-
Fujitsu FMWCC42
Manual
-
Fujitsu FTP-607 Series
Manual