Page 2 - Absolute Maximum Ratings; Recommended Operating Conditions; Electrical Characteristics; Transmitter; Receiver
DELTA ELECTRONICS, INC. 2 Sep., 2006 Rev. 0B www.deltaww.com Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Note Storage Temperature Ts -40 85 ºC Supply Voltage V CC 0 5 V Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Unit Note Case Operating Temperature T C -5 70 º...
Page 3 - Optical Characteristics; Mask of the eye diagram for the optical transmit signal
DELTA ELECTRONICS, INC. 3 Sep., 2006 Rev. 0B www.deltaww.com Optical Characteristics (V CC =3.135V to 3.465V, Data Rate=155Mb/sec, PRBS=2 23 -1 NRZ, 62.5/125 µ m MMF) Parameter Symbol Min. Typ. Max. Unit Note Transmitter Output Optical Power (Avg.) P O -20 -14 dBm Optical Extinction Ratio ER 9 dB Ce...
Page 6 - Recommend Circuit Schematic; SerDes IC; * Depands on SerDes IC us ed
DELTA ELECTRONICS, INC. 6 Sep., 2006 Rev. 0B www.deltaww.com Recommend Circuit Schematic Las er Dio d e Pho t o Dio de 1 uH 1 uH 0 .1 u F 1 0u F 0 .1 u F 0 .0 1 uF 0 .0 1 uF 0 .0 1 uF 0 .0 1 uF 0 .1 u F 1 0u F RES1 1 00 Oh ms * RES1 RES1 RES1 1 0k Oh ms 1 00 Oh ms VCC Protocol Vcc SerDes IC Protocol...
Page 7 - Package Outline Drawing for Metal Housing with Bail de-latch
DELTA ELECTRONICS, INC. 7 Sep., 2006 Rev. 0B www.deltaww.com Package Outline Drawing for Metal Housing with Bail de-latch
Page 8 - SFP timing parameters for SFP management; Parameter Symbol
DELTA ELECTRONICS, INC. 8 Sep., 2006 Rev. 0B www.deltaww.com SFP timing parameters for SFP management Parameter Symbol Min. Max. Unit Unit Conditions TX_DISABLE Assert time t_off 10 µ sec Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal TX_DISABLE Negate time...
Page 9 - SFP timing parameters:; SFP TX_DISABLE timing during normal operation.
DELTA ELECTRONICS, INC. 9 Sep., 2006 Rev. 0B www.deltaww.com SFP timing parameters: Power on initialization of SFP transceiver, TX_DISABLE negated Power on initialization of SFP, TX_DISABLE asserted Initialization during hot plugging of SFP TRANSCEIVER. Example of initialization during hot plugging,...
Page 11 - Blank; Related SFP products
DELTA ELECTRONICS, INC. 11 Sep., 2006 Rev. 0B www.deltaww.com Regulatory Compliance Feature Reference Performance Electromagnetic Interference (EMI) FCC Class B EN 55022 Class B (CISPR 22A) Radio Frequency Electromagnetic Field EN 61000-4-3 IEC 1000-4-3 Electrostatic Discharge to the Duplex LC Recep...