Page 2 - F l o o r S t a n d i n g U n i t; Air Conditioners; Technical Data
FVXS-F F l o o r S t a n d i n g U n i t Air Conditioners Technical Data w w w . d a i k i n . e u
Page 3 - TABLE OF CONTENTS
• Split Sky Air • Indoor units 1 • Indoor units • R-410A • FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Features
• Indoor units • R-410A • FVXS-FV1B • Split Sky Air • Indoor units 2 1 Features In do or u ni t S p l i t S k y FV XS -F V1 B R- 41 0A • Stylish design • Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. • Titanium apatite photocatalytic air ...
Page 5 - Specifications; -1 For indoor units only
• Split Sky Air • Indoor units 3 • Indoor units • R-410A • FVXS-FV1B 2 Specifications 2-1 For indoor units only FVXS25FV1B FVXS35FV1B FVXS50FV1B Nominal input (Indoor only) Cooling kW 0.015 0.015 0.027 Heating kW 0.017 2-2 Technical Specifications FVXS25FV1B FVXS35FV1B FVXS50FV1B Casing Colour White...
Page 6 - -3 Electrical Specifications
• Indoor units • R-410A • FVXS-FV1B • Split Sky Air • Indoor units 4 2 Specifications Temperature control Microcomputer control Standard Accessories Item Installation manual Quantity 1 1 1 Item Operation manual Quantity 1 1 1 Item Wireless remote control Quantity 1 1 1 Item Batteries Quantity 2 2 2 ...
Page 7 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
• Split Sky Air • Indoor units 5 • Indoor units • R-410A • FVXS-FV1B 3 Dimensional drawing & centre of gravity 3 - 1 Dimensional drawing 3D056135 FVXS25-35F unit (mm) Main unit fixing screw Note) 1. The mark ( Y ) shows piping direction Main unit fixed screws 666 (half concealed) Operation lamp ...
Page 8 - - 2 Centre of gravity
• Indoor units • R-410A • FVXS-FV1B • Split Sky Air • Indoor units 6 3 Dimensional drawing & centre of gravity 3 - 2 Centre of gravity FVXS25-50F 4D056197A
Page 9 - Piping diagram
• Split Sky Air • Indoor units 7 • Indoor units • R-410A • FVXS-FV1B 4 Piping diagram FVXS25-35F Indoor unit Heat exchanger Fan motor Field piping Field piping Refrigerant flow Cooling Heating Turbo fan Thermistor onheat exchanger Muffler assy 4D056137A FVXS50F Indoor unit Heat exchanger Fan motor F...
Page 10 - Wiring diagram
• Indoor units • R-410A • FVXS-FV1B • Split Sky Air • Indoor units 8 5 Wiring diagram 5 - 1 Wiring diagram FVXS25-50F g Field wiring Outdoor Indoor R : Protective earth F1U : Fuse H1P,H2P : Pilot lamp M1F : Fan motor M1S : Swing motor M2S : Lower air outlet motor PCB1 ∼ PCB4 : Printed circuit board ...
Page 11 - Sound data; - 1 Sound pressure spectrum
• Split Sky Air • Indoor units 9 • Indoor units • R-410A • FVXS-FV1B 6 Sound data 6 - 1 Sound pressure spectrum Octave band sound pressure level dB:(0dB = 0.0002 μ bar) Octave band center frequency (Hz) FVXS25F (Cooling) approximate threshold hearing for continuous noise Legend 50Hz 220-240V (H)50Hz...