Page 2 - SAFETY CONSIDERATIONS
SAFETY CONSIDERATIONS Read these SAFETY CONSIDERATIONS for Installation carefully before installing the Daikin ENVi thermostat kit. After completing the installation, make sure that the unit operates properly. Instruct the customer on how to operate and maintain the thermostat. Inform customers that...
Page 3 - CONTENTS
CONTENTS GETTING STARTED 1 Welcome 1Contractor Thermostat Registration 1 Package Contents 2 Before You Begin 3 Daikin System Compatibility 4 Approvals 4 FCC Compliance Statement 4 Specifications 6Wiring Requirements 7 INSTALLING THE THERMOSTAT KIT 7 Step 1. Power Off the Daikin Indoor Unit 7 Step 2....
Page 5 - GETTING STARTED; Welcome
GETTING STARTED Welcome The Daikin ENVi thermostat kit has been designed to ensure the installation process is simple and efficient. This step-by-step Installation Manual will walk you through all aspects of the installation.To ensure an on-going service relationship with your customers, please regi...
Page 6 - Package Contents; The Daikin ENVi thermostat kit includes the
Package Contents The Daikin ENVi thermostat kit includes the following items. ENVi Thermostat Trim Plate DPCA with Power Cable Double-Sided Adhesive Screws (4) and Drywall Anchors (4) Serial Number Sticker Wire Ties (2) Installation and User Manuals Wiring Harness Daikin ENVi Thermostat Kit Contents...
Page 7 - Before You Begin
Before You Begin This product is intended to be installed by trained service professionals.This manual explains the procedures for installing the Daikin ENVi thermostat. Please read it carefully before beginning the installation. For information on how to operate the Daikin ENVi thermostat, please s...
Page 8 - Daikin System Compatibility; Any auxiliary heater that requires air flow; Approvals
Daikin System Compatibility The Daikin ENVi thermostat is designed to operate only with the Daikin Heat Pump and Cooling Indoor Units where the BRC944 wired remote controller is applicable.The Daikin ENVi thermostat supports the following systems: Single-Split system Multi-Split system (2 to 8 ports...
Page 10 - Specifications; Thermostat Specifications; DPCA Specifications
Specifications Thermostat Specifications Temperature Heat Set Point Range 45 to 80 °F (7 to 26.5 °C) Cool Set Point Range 65 to 95 °F (18.5 to 35 °C) Display Range 40 to 100 °F (5 to 37 °C) Sensitivity +/- 1 °F (0.5 °C) Operating Range 32 to 130 °F (0 to 55 °C) Humidity Display Range 20 to 90% R.H. ...
Page 11 - Wiring Requirements; The Daikin ENVi thermostat uses 4-wire low-voltage cable to; INSTALLING THE THERMOSTAT KIT; Step 1. Power Off the Daikin Indoor Unit; Before installing the Daikin ENVi thermostat kit, disconnect the
Wiring Requirements The Daikin ENVi thermostat uses 4-wire low-voltage cable to connect to the Daikin Power and Communication Adapter (DPCA) which in turn connects to the Indoor Unit. The maximum wire length between the Daikin ENVi thermostat and the DPCA is as follows: 18 AWG: 1250 ft/380 m 20 AWG:...
Page 12 - Step 2. Position and Wire the DPCA; P1 Terminal; P2 Terminal; DPCA; Cover
Step 2. Position and Wire the DPCA The Daikin Power and Communication Adapter (DPCA) provides an interface between the thermostat and Indoor Unit. To install the DPCA: 1. Position the DPCA in a suitable location, away from water and near the Indoor Unit (for example, a backside cavity of a wall-moun...
Page 14 - Step 3. Install the Daikin ENVi Thermostat
Step 3. Install the Daikin ENVi Thermostat The ideal location for the thermostat is approximately 5 ft (1.5 m) above floor level in the main living area.Do not install the thermostat: Close to sources of heat such as incandescent lights Near supply heating/cooling sources In direct sunlight On exter...
Page 16 - Attach the Daikin ENVi thermostat to the
Step 4. Connect the Thermostat Wiring Use the field-supplied 4-wire low-voltage cable to connect the thermostat to the DPCA. To connect the thermostat to the DPCA: 1. Connect the wires as shown: 2. Attach the Daikin ENVi thermostat to the backplate. Ensure that the pins on the thermostat align with ...
Page 18 - NAVIGATING THE MENUS; Using the Navigation Buttons
NAVIGATING THE MENUS The Daikin ENVi thermostat has an easy-to-read color screen that displays all the information you need to configure the thermostat. Use the navigation buttons on the right to quickly change the temperature, access features, and configure settings. Using the Navigation Buttons Th...
Page 20 - Preferences; Intelligent Eye; To configure the; Settings; Yes
CONFIGURING THE DAIKIN ENVi THERMOSTAT The first step after installing the Daikin ENVi thermostat is to configure the thermostat settings for the Indoor Unit. Preferences This section describes the user preferences that should be configured during installation. For a complete description of all user...
Page 21 - Installation Settings; Only visible if the Indoor Unit supports heat or an; System Settings; Min Cycle Off Time; Sets the minimum; Min Outdoor Temp
Installation Settings The Installation Settings let you configure the equipment connected to the Daikin ENVi thermostat. Allow Auto Heat/Cool Enabling this option allows the user to select auto change-over as a system mode. Only visible if the Indoor Unit supports heat or an auxiliary heat source is...
Page 22 - Cool Differential Temp
damage to the compressor. You can also set this value to determine when you want the auxiliary heat (if installed) to engage to help meet the set temperature. The temperature range is adjustable from –10 to 65 °F (–23.3 to 18.3 °C) or disabled by default. This feature uses the Internet to obtain the...
Page 24 - Aux Heat Settings
reached). Options are Auto (default) and 1 to 10 °F (0.6 to 5.6 °C). Only visible if Indoor Unit supports heat and an auxiliary heat source is also configured. Heat Pump to Aux Runtime The maximum amount of time the heat pump will run before engaging Aux Heat. Options are Auto (default), Disabled, a...
Page 25 - Fan Configuration; Heating Mode Speeds; Force System Off
Above this level, the auxiliary heat will not be activated. The temperature is adjustable from 0 to 80 °F (-17.8 to 26.5 °C) in increments of 0.5°F (0.3°C). The default value is 70°F (21°C). Fan Configuration The Fan Configuration settings map the Indoor Unit’s internal fan speeds to the fan speed o...
Page 26 - Reset Equipment or User Settings; Reset Registration; To reset the Daikin ENVi
Tstat Temp Correction Lets you program an offset between the real temperature at the thermostat and the displayed temperature. If you find that the temperature where the thermostat is located does not represent the room temperature, change the offset to compensate for the difference. The correct tem...
Page 27 - Reset Contractor Info; Rebooting the Daikin ENVi; To select the
Reset Contractor Info Resets any information about the Contractor who installed the Daikin ENVi thermostat. Rebooting the Daikin ENVi thermostat You can reboot the Daikin ENVi thermostat by pressing the physical hardware reset button, located through an opening in the bottom left corner of the Daiki...
Page 28 - System Service; To configure Reminders; Reminders and
CONFIGURING REMINDERS AND ALERTS The Daikin ENVi thermostat can generate periodic maintenance reminders that help the homeowner know when to perform periodic maintenance. The thermostat can also generate alerts if the system detects an error or if the temperature in the home goes over or under a pre...
Page 30 - List of Alerts; some of these may not apply.
List of Alerts Below is a complete list of alerts. Depending on your configuration, some of these may not apply. Low Temp Limit Temperature in the home is too low. High Temp Limit Temperature in the home is too high. Heat Not Responding The system has failed to heat the home. Cool Not Responding The...
Page 31 - ONE-YEAR LIMITED WARRANTY
ONE-YEAR LIMITED WARRANTY Daikin AC (Americas), Inc., (“Daikin AC”) warrants that for a period of one (1) year from the date of purchase by the end-user (“Customer”), the Daikin ENVi thermostat (the “Product”) shall be free of defects in materials and workmanship under normal use and service. During...