Page 2 - Basic Cabling for Subtending
8 Installation - Subtended Network 78-5481-02 09/15/98 Cisco 6100 Set Up and Installation Manual 8-2 8.1.1 Cable Diagram - Subtending The following is an illustration of the basic cabling of a subtended 6100. Some connectors are notused because they are specific to one of the other configurations of...
Page 3 - Installation Procedures - Subtending; Installation Steps Checklist
78-5481-02 09/15/98 Installation - Subtended Network 8 Cisco 6100 Set Up and Installation Manual 8-3 8.2 Installation Procedures - Subtending The following table shows a check list of the installation steps for subtended 6100s. Then subsequentsubsections, as noted in the last column of the Table 8-1...
Page 4 - Connecting the DS3 Subtending Card; DS3 Subtend Card
8 Installation - Subtended Network 78-5481-02 09/15/98 Cisco 6100 Set Up and Installation Manual 8-4 8.2.2 Connecting the DS3 Subtending Card The DS3 subtending I/O card has two sets of DS3 75-ohm coaxial BNC connectors. Each setconsists of a transmit and a receive connector. The following figure il...
Page 5 - DS3 Subtending Card Connector
78-5481-02 09/15/98 Installation - Subtended Network 8 Cisco 6100 Set Up and Installation Manual 8-5 Connect the DS3 subtending I/O card to connector J48, a 96-pin DIN connector, on the subtendinghost 6100 MC backplane. Refer to the Figure 8-3 for the location of these connectors. Figure 8-3 DS3 Sub...
Page 6 - DS3 Subtend Card - Standoffs
8 Installation - Subtended Network 78-5481-02 09/15/98 Cisco 6100 Set Up and Installation Manual 8-6 Figure 8-4 DS3 Subtend Card - Standoffs See Figure 8-1 for an illustration of the cabling between the system I/O card on the subtended node6100 and the DS3 subtend card on the subtended 6100. DS3 car...
Page 7 - Installing the DS3 Subtend Module; DS3 Subtending Host Module
78-5481-02 09/15/98 Installation - Subtended Network 8 Cisco 6100 Set Up and Installation Manual 8-7 8.2.3 Installing the DS3 Subtend Module The DS3 NI module should be installed in slot 10 of the host 6100 before the ATU-Cs are installedin the subtended node 6100. The DS3 subtend module should be i...
Page 8 - Thick Coaxial Cable through Ferrite Bead
8 Installation - Subtended Network 78-5481-02 09/15/98 Cisco 6100 Set Up and Installation Manual 8-8 Using either the ferrite beads shipped with the DS3 NI module (type 43) or ones that use ferritematerial type 43 or 44 with an impedance of >200 ohms +/- 20% at 100 MHz, attach the beads closeto t...
Page 9 - Ferrite Beads Close to BNC Connectors
78-5481-02 09/15/98 Installation - Subtended Network 8 Cisco 6100 Set Up and Installation Manual 8-9 Figure 8-8 shows the ferrite beads on the coaxial cable close to the BNC connectors on the DS3subtend card. Figure 8-8 Ferrite Beads Close to BNC Connectors 8.2.5 Completing the Installation When the...
Page 10 - Adding a DS3 Subtend Card; Adding Standoffs for a DS3 Card
8 Installation - Subtended Network 78-5481-02 09/15/98 Cisco 6100 Set Up and Installation Manual 8-10 8.3 Adding a DS3 Subtend Card If you have an existing MC and you need to add a DS3 subtend card, you will need to remove twoof the screws from the backplane, add the standoffs shipped with the card,...
Page 11 - Connect the DS3 I/O card to connector J48 as shown in Figure 8-4.
78-5481-02 09/15/98 Installation - Subtended Network 8 Cisco 6100 Set Up and Installation Manual 8-11 If you are installing the DS3 subtending I/O card on an older MC, you will need to add the standoffsto mount the card. The following procedures describe how to add the standoffs. Figure 8-4 illustra...