Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Produc...
Page 3 - Wireless Remote, Electric Start; PORTABLE GENERATOR; TABLE Of CONTENTS
41570 Wireless Remote, Electric Start PORTABLE GENERATOR 9500 Starting Watts/7500 Running Watts TABLE Of CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Wireless Remot...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 41570-20140522 ENGLISH 41570 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This ...
Page 5 - MANUAL CONVENTIONS; CAUTION; DANGER; WARNING
REV 41570-20140522 2 41570 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to...
Page 6 - SAfETy RULES; When servicing the generator:
3 REV 41570-20140522 ENGLISH 41570 SAfETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only ...
Page 7 - When adding or removing fuel :
REV 41570-20140522 4 41570 ENGLISH SAfETy RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any mat...
Page 8 - CONTROLS AND fEATURES; Generator
5 REV 41570-20140522 ENGLISH 41570 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. CONTROLS AND fEATURES (1) Fuel Tank – 5.9 gallon (22.4 L) capacity fuel tank. (2) Auto...
Page 9 - Power Panel
REV 41570-20140522 6 41570 ENGLISH Power Panel CONTROLS AND fEATURES 4 1 2 3 5 7 6 9 8 (1) Ignition Switch – Used to start or stop the generator. (2) Battery Switch – Enables /disables starting electrically – via remotely or by ignition switch. (3) 120/240 Volt AC, 30 Amp Twist-Lock Receptacle (NEMA...
Page 10 - Wireless Remote Control; Remote Control Power Consumption
7 REV 41570-20140522 ENGLISH 41570 CONTROLS AND fEATURES Wireless Remote Control This generator is equipped with a wireless remote control system for starting and stopping. The system consists of (4) main components:1. Receiver Control Module (RCM)2. Wireless Remote3. Battery Switch4. Ignition Switc...
Page 11 - Parts Included; Wheel Kit
REV 41570-20140522 8 41570 ENGLISH Parts Included CONTROLS AND fEATURES Your 41570 gasoline powered generator ships with the following parts: Wheel Kit – 10 in. Wheel 2 – Bushing 2 – Flange Bolt (M10x120 for Wheel) 2 – Lock Nut (M10) 2 – Flat Washer Ø10 2 – Support Leg (w/vibration mounts) 1 – Flang...
Page 12 - ASSEMBLy; Remove the Generator from the Shipping Carton; Install the Wheel Kit; Connect the Battery
9 REV 41570-20140522 ENGLISH 41570 ASSEMBLy Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. P...
Page 13 - Add Engine Oil; Add Engine Oil Cont’d.
REV 41570-20140522 10 41570 ENGLISH Add Engine Oil ASSEMBLy Add Engine Oil Cont’d. 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add up to 1.2 qt. (1.1 L) of oil (included) and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level...
Page 14 - Grounding; Add fuel
11 REV 41570-20140522 ENGLISH 41570 ASSEMBLy Add fuel Cont’d. Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of ...
Page 15 - OPERATION; Generator Location; Surge Protection
REV 41570-20140522 12 41570 ENGLISH OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some...
Page 16 - Wireless Remote and Electric Start; Recoil Start; NOTE
13 REV 41570-20140522 ENGLISH 41570 OPERATION Wireless Remote and Electric Start Wireless remote starting is only possible within 80 feet of the generator.Do not attempt to adjust the carburetor choke. The wireless remote and electric starting systems will automatically close and open the choke.1. M...
Page 17 - Connecting Electrical Loads; Stopping the Engine; Stopping the Engine Cont’d.
REV 41570-20140522 14 41570 ENGLISH OPERATION Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connec...
Page 18 - Do Not Overload Generator; Capacity; Power Management; Operation at High Altitude
15 REV 41570-20140522 ENGLISH 41570 Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the amou...
Page 19 - Air filter; MAINTENANCE AND STORAGE; Engine Maintenance; Oil
REV 41570-20140522 16 41570 ENGLISH The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. Never operate a damaged or defective generator. Tampering with the factory set governor will vo...
Page 20 - Adjustments; Generator Maintenance; Spark Arrester
17 REV 41570-20140522 ENGLISH 41570 Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or adjus...
Page 21 - Storage; Generator Storage; Remote Control Battery; Disconnect the Battery; Charge the Battery
REV 41570-20140522 18 41570 ENGLISH MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the t...
Page 22 - SPECIfICATIONS
19 REV 41570-20140522 ENGLISH 41570 fCC Statement for Remote Control Device 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference.(2) This device must accept any interference received, including...
Page 23 - Wiring Diagram; AVR
REV 41570-20140522 20 41570 ENGLISH Wiring Diagram SPECIfICATIONS L W G B Y R YELL OW BLA C K B LU E G RE EN RE D WHI TE B r W H ITE B LU E GREEN YE LL OW W H ITE GREE N BRO W N BLACK W H IT E B/ W W/ L G /Y W /G B Y B /G E N GI N E BLO C K GENERA TO R BLO C K SPARKING P LU G IG N IT IO N C OI L O I...
Page 24 - Parts Diagram
21 REV 41570-20140522 ENGLISH 41570 SPECIfICATIONS Parts Diagram 1 2 4 5 6 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 37 42 43 44 36 37 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 6364 65 66 68 69 70 71 72 73 74 75 76 77 78 26 79 80 81 8...
Page 25 - Parts List
REV 41570-20140522 22 41570 ENGLISH Parts List # Part Number Description Qty 1 2.06.006 Clamp (Ø7× Ø1) 2 2 152.070013.03 Pipe, Air Cleaner, 135MM 1 3 2.06.004 Clamp (Ø8 × Ø1) 1 4 2.05.001 Clamp (Ø8 × 6.5) 2 5 152.070014.07 Pipe, Reversal Valve, 780MM 1 6 1.5789.0608 Flange Bolt M6× 8 6 7 152.070018....
Page 26 - Engine Parts Diagram
23 REV 41570-20140522 ENGLISH 41570 SPECIfICATIONS Engine Parts Diagram 4 5 6 4 4 0 10 2 10 3 10 4 10 5 9 1 10 6 10 7 11 0 10 9 10 8 8 5 1 0 1 2 3 4 5 6 7 8 9 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 1 6 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 3 3 4 3 5 1 2 3 6 3 0 3 7 3 8 2 3 3 9 4 1 4 2 4 3 4 4 4 6 4 7 4...
Page 28 - TROUBLESHOOTING; for further technical support :
25 REV 41570-20140522 ENGLISH 41570 TROUBLESHOOTING for further technical support : Technical ServiceMon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Un...
Page 29 - WARRANTy; Installation, Use and Maintenance Cont’d.
REV 41570-20140522 26 41570 ENGLISH WARRANTy WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locatio...